Broseley eVolution 4 Скачать руководство пользователя страница 28

28

 

 

eVo

 

4&7

 

Inset

 

MS07

11

 

 

11/07/11

 

 

Where

 

there

 

is

 

no

 

direct

 

and

 

sealed

 

connection

 

to

 

the

 

chimney

 

or

 

chimney

 

liner

 

(where

 

fitted)

 

it

 

is

 

essential

 

that

 

the

 

fire

 

is

 

sealed

 

to

 

the

 

surround

 

and

 

the

 

hearth

 

using

 

fire

 

cement

 

for

 

a

 

gas

tight

 

seal

 

in

 

accordance

 

with

 

BS

 

8303

1.

 

Fitting

 

the

 

stove

 

eVo4

 

Inset

 

Remove

 

the

 

flue

 

pipe

 

adaptor

 

(if

 

fitted)

 

Insert

 

the

 

stove

 

into

 

the

 

fireplace

 

opening

 

ensuring

 

that

 

the

 

rope

 

forms

 

an

 

airtight

 

seal

 

against

 

the

 

fireplace

 

and

 

hearth.

 

Secure

 

the

 

stove

 

with

 

screws

 

(not

 

supplied

 

as

 

they

 

need

 

to

 

be

 

suitable

 

to

 

screw

 

into

 

the

 

hearth

 

material)

 

into

 

the

 

hearth

 

through

 

the

 

holes

 

located

 

inside

 

the

 

stove

 

 

holes

 

‘A’

 

and

 

‘B’.

 

There

 

are

 

two

 

holes

 

located

 

on

 

the

 

left

 

and

 

right

 

hand

 

side

 

and

 

one

 

hole

 

located

 

in

 

the

 

middle

 

of

 

the

 

stove.

 

You

 

should

 

use

 

all

 

3

 

holes

 

to

 

secure

 

the

 

appliance

 

as

 

holes

 

not

 

used

 

will

 

ensure

 

excess

 

air

 

enters

 

the

 

combustion

 

chamber

 

which

 

can

 

cause

 

issues

 

with

 

the

 

air

 

wash.

 

If

 

all

 

holes

 

are

 

not

 

used

 

they

 

must

 

be

 

blocked

 

with

 

silicone

 

or

 

firecement.

 

 

 

Then

 

use

 

the

 

chimney

 

clamp

 

(C)

 

to

 

hold

 

the

 

top

 

of

 

the

 

appliance

 

against

 

the

 

fireplace

 

opening

 

ensuring

 

again

 

that

 

an

 

airtight

 

seal

 

is

 

formed.

  

It

 

may

 

be

 

a

 

requirement

 

to

 

drill

 

a

 

clearance

 

hole

 

through

 

the

 

chimney

 

breast

 

on

 

some

 

installations

 

for

 

clamp

 

C.

 

Содержание eVolution 4

Страница 1: ...ver a new o xide alarm mu rbon monoxide n of an alarm m r servicing and ate must be ob ents will void t t d Operat de covers MISSIONED BY r replacement ust be fitted in e alarm is avai must not be co...

Страница 2: ...is essential that you employ the services of an experienced heating engineer to calculate the heat demand you have and that s he in turn calculate the size of stove that would be most suitable for yo...

Страница 3: ...in the course of installation then please seek specialist guidance and use appropriate protective equipment Metal Parts When installing or servicing this stove care should be taken to avoid the risk o...

Страница 4: ...n a smoke control area unless it is used in an exempt appliance exempted from the controls which generally apply in the smoke control area The Secretary of State for Environment Food and Rural Affairs...

Страница 5: ...ted above nor does it cover instructions for the use of other fuels Under NO circumstances burn petroleum coke as it will burn out the internal grate and baffle plates in a very short period of time a...

Страница 6: ...ve of warming the stove as quickly as possible Firstly a double handful of kindling equivalent to the weight of about 1 kg should be lit with chemical firelighters The primary air and secondary air co...

Страница 7: ...the fire can then be allowed to burn down to a suitable condition at a preferable air slider position For start of further re fuelling apply sequence in the previous 2 sentences FURTHER REQUIREMENTS 1...

Страница 8: ...e main combu to right To o ol fully to the dampers open ers door left Volution Inse s tertiary air w ustion air and open the cont e right n can cause e open except t stove Cont which can be d air wash...

Страница 9: ...epers as this contains harmful toxins or flammables which may cause the wood to spit Overnight burning is difficult to achieve with logs Curing the Stove Before lighting the stove check with the insta...

Страница 10: ...t occur However if a chimney fire does occur turn the air control setting to the minimum and tightly close the doors of the stove This should cause the chimney fire to go out in which case the control...

Страница 11: ...fibre rope on the doors and the casting may have been lost adjust door handle lock nuts to reinstate this seal The chimney has excessive draw seek installers advice on this point The fibre rope seal...

Страница 12: ...t is our general policy to supply specialist Fireplace shops These shops can offer an after sales service and will be able to offer advice when necessary CO Alarms Building regulations require that wh...

Страница 13: ...t least 600mm from any combustible material such as beams or skirting The hearth does not need to be constructional but must be at least 12mm thick The hearth protrusion in front of the stove to carpe...

Страница 14: ...accordance with the provisions of Building Regulations Approved Document J If installation is into an existing chimney then the chimney must be sound and have no cracks or other faults which might all...

Страница 15: ...ion does persist then the following immediate action should be taken a Open doors and windows to ventilate the room and then leave the premises b Let the fire go out c Check for flue or chimney blocka...

Страница 16: ...eVo 4 7 I Inset MS07 11 SUMMARY OF FLUE PRO OBLEMS 11 0 16 07 11...

Страница 17: ...ning wood logs in a smokeless zone It is mandatory that when installing the stove in a smokeless zone that the airwash deflector plate be altered to ensure some permanent air is available Following th...

Страница 18: ...that when installing the stove in a smokeless zone that the airwash deflector plate be altered to ensure some permanent air is available Following the image below the installer will need to change th...

Страница 19: ...y connect the flue it is possible to remove all vermiculite and access the adaptor spigot from inside the stove To refit the vermiculite perform the following sequence in reverse Be careful when remov...

Страница 20: ...20 eVo 4 7 Inset MS07 11 11 07 11 STEP 2 STEP 3...

Страница 21: ...21 eVo 4 7 Inset MS07 11 11 07 11 STEP 4 STEP 5...

Страница 22: ...y connect the flue it is possible to remove all vermiculite and access the adaptor spigot from inside the stove To refit the vermiculite perform the following sequence in reverse To start removing lif...

Страница 23: ...23 eVo 4 7 Inset MS07 11 11 07 11 STEP 1 STEP 2...

Страница 24: ...24 eVo 4 7 Inset MS07 11 11 07 11 STEP 3 STEP 4...

Страница 25: ...25 eVo 4 7 Inset MS07 11 11 07 11 STEP 5 STEP 6...

Страница 26: ...26 eVo 4 7 Inset MS07 11 11 07 11 STEP 7 STEP 8...

Страница 27: ...the adaptor spigot Extra assurance may be required to maintain an air tight seal between the flue pipe and the adaptor spigot This can be obtained by using rope and or fire cement Then insert the stov...

Страница 28: ...be suitable to screw into the hearth material into the hearth through the holes located inside the stove holes A and B There are two holes located on the left and right hand side and one hole located...

Страница 29: ...is the engineer s discretion as to removing the stove and drilling the hearth or screwing into it directly Either way it is recommended that at least 2 fixing points opposite corners are used Please n...

Страница 30: ...do should smoke or fumes be emitted from the stove The customer should be warned to use a fireguard to BS 8423 2002in the presence of children aged and or infirm persons Combustion Air Supply In order...

Страница 31: ...31 eVo 4 7 Inset MS07 11 11 07 11 eVo 4 Inset Dimensions...

Страница 32: ...32 eVo 4 7 Inset MS07 11 11 07 11 eVo 7 Inset Dimensions LIMITED WARRANTY...

Страница 33: ...units Replaced parts or components will become the property of Broseley Fires Should you wish to claim under the warranty please contact the supplier dealer from whom you purchased the appliance Do no...

Отзывы: