14
eVo
4&7
Inset
MS07
‐
11
11/07/11
Chimney
and
Flue
Requirements
The
liner
diameter
must
not
be
less
than
6
inch
(150mm)
and
no
more
than
9
by
9
inch
(225mm
by
225mm)
square.
It
is
most
important
that
there
is
no
obstruction
in
the
flue.
Sweep
clean
immediately
before
installation
of
the
stove.
If
the
chimney
has
previously
been
used
for
an
open
fire
it
is
recommended
that
it
be
swept
for
a
second
time
after
the
stove
has
been
used
for
a
month.
As
a
closed
appliance
operates
at
a
higher
flue
temperature,
it
is
possible
for
deposits
which
previously
adhered
to
now
be
dislodged,
with
the
consequent
risk
of
soot
falls
and
flue
blockage.
A
flue
draught
of
minimum
12Pa
(0.05ins
wg)
to
a
maximum
16
Pa
(0.065ins
wg)
is
required
for
satisfactory
appliance
performance.
A
properly
built
masonry
or
factory
constructed
chimney,
preferably
with
a
height
of
5
metres
or
more,
should
ensure
a
consistent
draught
(draw)
under
a
variety
of
weather
conditions.
The
flue
draught
should
be
checked
‘under
‐
fire’
at
high
output
and
if
it
exceeds
the
recommended
maximum,
a
draught
stabiliser
should
be
fitted
to
prevent
over
firing
(see
5
below).
This
appliance
must
not
be
connected
to
a
flue
serving
another
heating
appliance.
The
outlet
from
the
chimney
should
be
above
the
roof
of
the
building
in
accordance
with
the
provisions
of
Building
Regulations
Approved
Document
J.
If
installation
is
into
an
existing
chimney
then
the
chimney
must
be
sound
and
have
no
cracks
or
other
faults
which
might
allow
fumes
into
the
house.
If
there
is
any
uncertainty,
seek
expert
advice
as
remedial
action
should
be
taken.
If
it
is
found
necessary
to
line
the
chimney
then
a
flue
liner
suitable
for
manufactured
or
naturally
occurring
smokeless
fuels
and
wood
logs
must
be
installed
in
accordance
with
Building
Regulations
Approved
Document
J.
If
there
is
no
existing
chimney
then
either
a
prefabricated
block
chimney
in
accordance
with
Building
Regulations
Approved
Document
J
or
a
twin
walled
insulated
stainless
steel
flue
to
BS
4543
can
be
used.
These
chimneys
must
be
fitted
in
accordance
with
the
manufacturer’s
instructions
and
Building
Regulations.
The
liner
diameter
must
not
be
less
than
6”.
If
the
draw
on
the
chimney
is
excessive,
a
flue
draught
stabiliser
will
help
to
slow
this
down.
An
excessive
draw
may
cause
over
firing
and
thus
cause
the
internal
components
of
the
stove
to
wear
out
quicker.
Any
bend
in
the
chimney
or
connecting
fluepipe
should
not
exceed
45
°
.
90
°
bends
should
not
be
used.
Adequate
provision
e.g.
easily
accessible
soot
door
or
doors
must
be
provided
for
sweeping
the
chimney
and
connecting
fluepipe.
With
reference
to
the
above
All
relevant
flue
or
chimney
installations
must
adhere
to
BS
EN
15287
‐
1:2007
Design,
installation
and
commissioning
of
chimneys.
Содержание eVolution 4
Страница 16: ...eVo 4 7 I Inset MS07 11 SUMMARY OF FLUE PRO OBLEMS 11 0 16 07 11...
Страница 20: ...20 eVo 4 7 Inset MS07 11 11 07 11 STEP 2 STEP 3...
Страница 21: ...21 eVo 4 7 Inset MS07 11 11 07 11 STEP 4 STEP 5...
Страница 23: ...23 eVo 4 7 Inset MS07 11 11 07 11 STEP 1 STEP 2...
Страница 24: ...24 eVo 4 7 Inset MS07 11 11 07 11 STEP 3 STEP 4...
Страница 25: ...25 eVo 4 7 Inset MS07 11 11 07 11 STEP 5 STEP 6...
Страница 26: ...26 eVo 4 7 Inset MS07 11 11 07 11 STEP 7 STEP 8...
Страница 31: ...31 eVo 4 7 Inset MS07 11 11 07 11 eVo 4 Inset Dimensions...
Страница 32: ...32 eVo 4 7 Inset MS07 11 11 07 11 eVo 7 Inset Dimensions LIMITED WARRANTY...