Page 19
Figure 15
8 Unpack the Spacer Bracket and secure it to the rear top of the firebox using two screws
supplied (see Figure 16).
Figure 16
9
Fit the isolation elbow onto the gas inlet tubing on the control valve and proceed to the
next stage of preparing the installation.
3.9.3 Preparing the Installation
General Notes
1. Please attempt to keep the hole sizes for
the flue ducts as close as possible to the
minimum dimensions of 125mm.This will
keep the installation tidy, reducing the
need for excessive use of sealant
afterwards.
2. Ensure any damp course, electrical
wiring, or any pipe work within the wall,
is not going to be affected by the
installation.
3. Any gas pipe concealed in the wall, floor
or cavity must be continuous and
enclosed within a gas tight sleeve. (Gas
Safety (Installation & Use) Regulations:
1998).
4. Ensure that the chosen position for the
appliance
will
comply
with
the
requirements detailed in
Section 3.5
P1 - self tapping
screws
P2 - Screws & nuts
Position A
Position B
REMOTE CONTROL VALVE
Spacer Bracket
Securing Screws