Page 2
Ventilation Requirements
1. This appliance does not require any additional fixed ventilation in the room where it is
fitted. It is a balanced flue appliance, whereby the air for combustion is drawn in from the
outside, and the products of combustion are evacuated to the outside through a concentric
flue duct system. (supplied)
2. In other EC countries, equivalent rules in force at the time of installation must be used.
Gas Supply
1. This range of gas fires are only suitable for use with Natural Gas (G20) at 20mbar supply
pressure. Conversion to Propane (G31), at 37mbar supply pressure, is
not
possible.
2. A separate means of isolating the gas supply should be provided near to the appliance
this is to facilitate servicing. An isolation valve (with a pressure test point) has been
supplied for this purpose.
Electrical Supply
Not applicable to this range of appliances, as no mains power is required.
Efficiency Declaration
The efficiency of this appliance has been measured as specified in BS EN 613:2001, and the
result is 80% net for Natural Gas. The gross calorific value of the fuel has been used for this
efficiency calculation. The test data from which it has been calculated, has been certified by
BSI Ltd. The efficiency value may be used in the UK Government Standard Assessment
Procedure (SAP) for energy rating of dwellings.
Hot Surfaces
All parts of this appliance, including any handles, get very hot during normal use, they are
classed as working surfaces. It is therefore recommended that a suitable fireguard be used for
the protection of young children, the elderly and infirm.