Section 1
8
9
GT1600 Meter Size 2 to 10
Applica
ti
on
Non-Electrical Equipment for use in Hazardous loca
ti
on
Area Classi
fi
ca
ti
on
II 2 G / II 2 D
Protec
ti
on Technique
Construc
ti
onal safety (c)
Technical Construc
ti
on File
203104000-1604 (Archived at DEKRA Cer
tifi
ca
ti
on B.V.)
Ambient Temperature
-20°C
≤
Ta
≤
70°C
Marking
II2G Ex h IIC T6…T4 Gb
II2D Ex h IIIC T120°C Db
Installa
ti
on Notes:
Special condi
ti
ons for safe use:
Resistance to Impact:
7 Joules
2 Joules
Degree of mechanical risk
low
External Cleaning
The product should be installed by suitably trained personnel, in accordance with the applicable code of
prac
ti
ce/ installa
ti
on standards for hazardous areas.
The
fl
owmeters shall be permanently grounded by means of the process connec
ti
ons in order to allow
discharge of electrosta
ti
c charges via the connec
ti
on to ground.
The actual maximum surface temperature of the equipment depends not on the equipment itself, but on
opera
ti
ng condi
ti
ons of the process
fl
uid/gas
fl
owing through the equipment. The equipment by itself does
not generate heat. Due to this reason the temperature class is marked as a range. The maximum permi
tt
ed
ambient and process temperature limits can be found in the opera
ti
ng instruc
ti
ons.
Supply grounding connec
ti
on by the process connec
ti
ons or earthing terminal.
Enclosure contains polycarbonate parts. If it is mounted in an area where the use of category 2G or 2D
apparatus is required, it must be installed such that igni
ti
on source due to propaga
ti
ng brush discharge
sparks are excluded.
The viewing window is made of polycarbonate. Protec
ti
on from impact should be considered for the viewing
Viewing window of the meter is made of non-conduc
ti
ve component. Care should be taken to ensure that
combus
ti
ble electrosta
ti
c charging will not build up during cleaning/maintenance of meter. Do not rub.
Metal Enclosure parts
Light-transmi
tti
ng part (polycarbonate window)
•
•
•
•
•
•
•
Table 1-5 GT1600 Size 2 to 10 Non-Electrical
Содержание GT1600
Страница 10: ...Section 1 Figure 1 4 Dimensions GT1600 Series See Dimensions Tables on following pages 5...
Страница 18: ...Section 1 13 Figure 1 5 Reed Switch Alarm UL Installation...
Страница 21: ...Section 1 Figure 1 7 Dimensions and Specs Intrinsically Safe Switch Isolators 16...
Страница 26: ...Section 4 Overview 21...
Страница 29: ...Section 5 Figure 5 2 GT1600 Sizes 7 10 Parts Assembly Drawing Ref GT16XX002_1 24...