background image

Brooks Automation

Part Number: 281947 Rev. C

 

Corporate Headquarters

15 Elizabeth Drive

Chelmsford, MA 01824 U.S.A.

 

For Technical Support:

Location

Contact Number

Website

North 
America

+1-800-447-5007 (Toll Free)
+1-978-262-2900 (Local)

http://www.brooks.com/

Europe

+49 800 000 9347 (Toll Free 
Germany)
+49 364 176 9999 6 (Has Toll)

http://www.brooks.com/

Japan

+81 120-255-390 (Toll Free)
+81 45-330-9005 (Local)

http://jp.brooks.com/

China

+86 400 627 6657

http://cn.brooks.com/

Taiwan

+886 080-003-5556 (Toll Free)
+886 3-5525258 (Local)

http://tw.brooks.com/

Korea

1800-5116 (Toll Free)

http://kr.brooks.com/

Singapore

+65 1-800-4-276657 (Toll Free)
+65 6309 0701 (Local)

http://www.brooks.com/

Contact Technical Publications directly: 

[email protected]

 

Accelerating Innovation

Copyright © 2018, Brooks Automation, Inc.

iii

Copyright © 2020, Brooks Automation, Inc.

iii

Содержание FluidX Scope USB

Страница 1: ...FluidX Scope USB User Manual Part Number 281947 Rev C...

Страница 2: ...pCooler TopLigner Tube Auditor Ultimate Blue VAC 407 VacuTran VersaPort and WaferEngine are trademarks of Brooks Automation Inc AcuTran AquaTrap Asyst the Cool Solutions logo Crossing Automation Cryod...

Страница 3: ...364 176 9999 6 Has Toll http www brooks com Japan 81 120 255 390 Toll Free 81 45 330 9005 Local http jp brooks com China 86 400 627 6657 http cn brooks com Taiwan 886 080 003 5556 Toll Free 886 3 5525...

Страница 4: ...e Science Systems BioStorage Technologies 2910 Fortune Circle West Suite E Indianapolis IN 46241 Tel 1 317 268 5500 Fax 1 317 390 1868 Brooks Automation Israel Ltd Mevo Yerach 5 Kiryat Gat 82000 Israe...

Страница 5: ...23 D 01109 Dresden Germany Tel 49 351 885 930 Fax 49 351 885 9322 Brooks Japan K K YOKKAICHI SERVICE CENTER Hikari Shokai Yokkaichi Bldg 2 26 Shinshinmachi Yokkaichi Mie 510 0094 Tel 81 59 359 5611 Fa...

Страница 6: ...5 No 32 Tai Yuen Street Chu Pei City Hsinchu County 302 Taiwan R O C Tel 886 3 552 5258 Fax G A 886 3 552 5255 Fax Sales 886 3 552 5200 Brooks Automation Korea Inc 35 Giheungdanji Ro 121Beon Gil Giheu...

Страница 7: ...ion 5 07 2014 Initial completion of the manual Revision A 95874 4 25 2017 Image Updates Revision B EC107106 10 1 2018 Brooks Re Branding and application of Brooks Templates Revision C EC118417 3 12 20...

Страница 8: ...tion 1 2 Installation 2 3 Attaching the Cable 3 4 Detaching the Cable 5 5 Reading a Tube 7 6 Reading a Linear Barcode 9 7 Reader Feedback 10 8 Quick Setup Codes 11 9 Preventative Maintenance 14 Append...

Страница 9: ...code reader It is capable of reading standard pre coded tubes from a range of manufacturers assuming they adhere to the ISO 16022 Data Matrix Two Dimensional Bar Code format The Scope USB can also re...

Страница 10: ...on 1 Ensure the connector cable is fully inserted into the Scope reader then connect the USB end to the USB port on the host device to power up the reader 2 The unit will beep twice and the LED will t...

Страница 11: ...3 Attaching the Cable The RJ50 cable is a multi pin connector and can be damaged if handled incorrectly Ensure that the cable is fully pushed home Errors may occur if the cable is not properly instal...

Страница 12: ...1947 Rev C Step Action 1 The connector cable is already attached but if necessary the cable can be inserted by slotting the RJ50 connector into the reader NOTE Ensure it is in the correct orientation...

Страница 13: ...t Number 281947 Rev C 4 Detaching the Cable Detaching a cable from the FluidX Scope USB is simple Step Action 1 Insert one end of a paperclip into the hole on the back of the reader Copyright 2020 Bro...

Страница 14: ...Brooks Automation FluidX Part Number 281947 Rev C Step Action 2 Apply pressure on the paperclip and gently pull the cable from the reader 6 Copyright 2020 Brooks Automation Inc...

Страница 15: ...ing mode so the button will need to be pressed to scan Step Action 1 Hold the tube approximately 0 5 cm 0 2 in from the scanning window and then press the button on top of the reader NOTE This will pr...

Страница 16: ...ON Quick Setup Code on Page 11 If the continuous scan has been enabled use the following instructions Step Action 1 Hold the tube approximately 0 5 cm 0 2 in from the scanning window NOTE This will pr...

Страница 17: ...near Barcode The FluidX Scope USB also reads linear barcodes Step Action 1 Use the targeting light to aim the beam over the linear barcode and press the read button The unit will beep once to indicate...

Страница 18: ...Feedback Audio Feedback Successfully powers up Green LED lights up 2 Beeps Attempting to decode Green LED light is off None Successful decode and data transfer via cable Green LED lights up 1 Beep Co...

Страница 19: ...e USB can be configured by scanning one of the codes from the table below NOTE The configuration change will take effect immediately and be saved to memory Action Setup Code Setting Continuous Scan Of...

Страница 20: ...ive OS Default Enable Alternative OS MAC Linux Optional Enabled reading of reversed codes black on white or white on black Default French Keyboard Mapping Optional German Keyboard Mapping Optional Jap...

Страница 21: ...281947 Rev C Action Setup Code Setting Reader ID and Firmware Technical Support STD Contrast Code 35 AGC Optional Suffix Enter Default Suffix Tab Optional Universal Keyboard Mapping Default Copyright...

Страница 22: ...riodically clean the scanning window with a moist non abrasive cloth to allow the best performance of the device The following are safe to use for cleaning as needed l IPA Isopropyl Alcohol l 70 alcoh...

Страница 23: ...Brooks Automation Part Number 281947 Rev C Appendix A Declaration of CE Conformity Copyright 2020 Brooks Automation Inc 15...