GLASS TUBE EXPLOSION HAZARD 

Plastic protective sleeve must remain over glass 

tube. Fasten meter windows securely. 

Do not operate above pressure and temperature 

limits. Avoid pressure and flow surges.

Do not service or repair while pressurized. 

Read and understand instruction manual. 

Failure to comply could result in serious 

personal injury or property damage.

 

Warning Model 1306

 

 

Warning Model 1305

 

Do not operate this instrument in excess of

 the specifications listed below. Failure to heed 

this warning can result in serious personal injury 

and/or damage to the equipment.

Essential Instructions 

Read this page before proceeding! 

 Brooks Instrument designs, manufactures and tests its products to meet many national and international standards. 
Because these instruments are sophisticated technical products, you must properly install, use and maintain them to 
ensure they continue to operate within their normal specifications. The following instructions must be adhered to and 
integrated into your safety program when installing, using and maintaining Brooks Products. 
• 

  Read all instructions prior to installing, operating and servicing the product. If this instruction manual is not 

the correct manual, please see back cover for local sales office contact information. Save this instruction 
manual for future reference. 

• 

 If you do not understand any of the instructions, contact your Brooks Instrument representative for clarification. 

• 

Follow all warnings, cautions and instructions marked on and supplied with the product. 

• 

 Inform and educate your personnel in the proper installation, operation and maintenance of the product. 

• 

 Install your equipment as specified in the installation instructions of the appropriate instruction manual and 
per applicable local and national codes. Connect all products to the proper electrical and pressure sources. 

• 

 To ensure proper performance, use qualified personnel to install, operate, update, program and maintain 
the product. 

•  

 When replacement parts are required, ensure that qualified people use replacement parts specified by 
Brooks Instrument. Unauthorized parts and procedures can affect the product's performance and place 
the safe operation of your process at risk. Look-alike substitutions may result in fire, electrical hazards or 
improper operation. 

• 

 Ensure that all equipment doors are closed and protective covers are in place, except when maintenance 
is being performed by qualified persons, to prevent electrical shock and personal injury. 

Pressure Equipment Directive (PED) 

 All pressure equipment with an internal pressure greater than 0.5 bar (g) and a size larger than 25mm or  
1" (inch) falls under the Pressure Equipment Directive (PED). The Directive is applicable within the European 
Economic Area (EU plus Norway, Iceland and Liechtenstein). Pressure equipment can be traded freely within 
this area once the PED has been complied with. 
• 

  Section 1 of this manual contains important safety and operating instructions related to the PED directive. 

• 

  Meters described in this manual are in compliance with EN directive 97/23/EC module H 

Conformity 

Assessment

• 

All Brooks Instrument Flowmeters fall under fluid group 1. 

•  

 Meters larger than 25mm or 1" (inch) are in compliance with category I, II, III of PED. • Meters of  25mm or 
1" (inch) or smaller are Sound Engineering Practice (SEP). 

Содержание GT 1305

Страница 1: ...Installation and Operation Manual X VA 1305 1306 eng eu PN 541 C 029 AAG April 2008 Models GT 1305 1306 1 Brooks O ring Seal Flowmeters Model 1306...

Страница 2: ...plied with the product Inform and educate your personnel in the proper installation operation and maintenance of the product Install your equipment as specified in the installation instructions of the...

Страница 3: ...highest quality available offering superior performance reliability and value to the user It is designed with the ever changing process conditions accuracy requirements and hostile process environment...

Страница 4: ...2 Installation 2 1 General 8 2 2 Return of equipment 8 2 3 Recommended storage practice 8 2 4 Return shipment 9 2 5 Transit precautions 9 2 6 Installation 10 Section 3 Operation 3 1 Start up 11 3 2 R...

Страница 5: ...3 Repeatability 0 5 Scale length GT 1305 75 mm GT 1306 127 mm Materials of construction End fittings Brass or 316 SS fitted in aluminium collar Metering tubes Borosilicate glass Floats 7 1306 Glass 31...

Страница 6: ...133 FE 1400 3580 8 36 8 40 0 108 0 8 66 Table 2 Flow Ranges For GT 1306 SIZE TUBE TYPE FLOAT MODEL WATER V I C 2 AIR CODE l h P kPa cSt m3n h P kPa 7 R 7M 127 1F Glass A1 31 0 25 1 1 20 0 25 316 SS A3...

Страница 7: ...with built in flow control needle valve The internal diaphragm actuated control valve is positioned by the incoming fluid pressure on one side of the diaphragm and outlet pressure spring action on the...

Страница 8: ...3569 Tel 215 362 3700 Fax 215 362 3745 E mail BrooksAm BrooksInstrument com www BrooksInstrument com Brooks Instrument Brooks Instrument Neonstraat 3 1 4 4 Kitasuna Koto Ku 6718 WX Ede Netherlands To...

Страница 9: ...Eu BrooksInstrument com Instrument must have been purged in accordance with the following All flow instruments returned to Brooks requires completion of Form RPR003 1 Brooks Instrument Decontamination...

Страница 10: ...t for damage during shipping b The indicator must be installed with the inlet at the bottom and the outlet at the top and must be installed as near vertical as possible to maintain indicator accuracy...

Страница 11: ...tion When initiating flow slowly open the valve to avoid a flow surge By pass is a help in bringing the flow on smoothly Avoid starting a pump to supply the flowmeter without the use of a valve upstre...

Страница 12: ...the polycarbonate sleeve surrounding the flow tube e Remove the float from the tube f Using a suitable solvent carefully swab and flush the inside of the metering tube Clean the float and blow dry al...

Страница 13: ...ation Should the equipment require repair contact the nearest sales service office It is important that servicing is performed only by trained and qualified service personnel If the equipment is not p...

Страница 14: ...R SIZE A B C D E F G H J SIZE 7 127 300 1 2 60 250 264 261 55 55 SIZE 8 127 300 1 2 60 250 264 261 55 55 SIZE 10 127 300 1 66 250 264 261 58 57 PANEL CUT OUT FOR BACK PANEL MOUNTING PANEL CUT OUT FOR...

Страница 15: ...Installation and Operation Manual X VA 1305 1306 eng eu PN 541 C 029 AAG April 2008 Models GT 1305 1306 15 Section 6 Exploded view and parts lists Section 6 Exploded view and part lists...

Страница 16: ...B 049 BNA 8 RV 31 316 SS FLOAT 2 1 346 B 050 BNA 8 RS 31 316 SS FLOAT 2 1 346 B 148 BNA 8 RV 8 316 SS FLOAT 2 1 346 B 149 BNA 8 RV 14 316 SS FLOAT 2 1 346 B 154 BNA 8 RS 8 316 SS FLOAT 2 1 346 B 155 B...

Страница 17: ...Kalrez CODE CONNECTION TYPE 1 NPT 2 BSP CODE SCALE TYPE A mm Decal cal curve Class 6 GT 1305 only B mm Decal cal curve Class 4 GT 1305 only C mm Decal cal curve Class 2 5 GT 1306 only D mm Decal cal c...

Страница 18: ...18 This page was intentionally left blank...

Страница 19: ...19 This page was intentionally left blank...

Страница 20: ...onger This limited warranty is the only warranty made by Seller and can be amended only in a writing signed by an authorized representative of Seller BROOKS SERVICE AND SUPPORT Brooks is committed to...

Отзывы: