Subject

:

Addendum to the Instruction Manual.

Reference

:

CE certification of Mass Flow Equipment

Date

:

January-1996.

The Brooks (electric/electronic) equipment bearing the CE mark has been successfully tested to the regulations of
the Electro Magnetic Compatibility (EMC directive 89/336/EEC).
Special attention however is required when selecting the signal cable to be used with CE marked equipment.

Quality of the signal cable, cable glands and connectors:

Brooks supplies high quality cable(s) which meets the specifications for CE certification.
If you provide your own signal cable you should use a cable which is overall completely screened with a 100%
shield.
“D” or “Circular” type connectors used should be shielded with a metal shield. If applicable, metal cable glands
must be used providing cable screen clamping.
 The cable screen should be connected to the metal shell or gland and shielded at both ends over 360 Degrees.
The shield should be terminated to a earth ground.
Card Edge Connectors are standard non-metallic. The cables used must be screened with 100% shield to comply
with CE certification.
The shield should be terminated to a earth ground.
For pin configuration : Please refer to the enclosed Instruction Manual.

Español

Brooks Instrument
407 West Vine St.
Hatfield, PA 19440
U.S.A.

Asunto

:

Addendum al Manual de Instrucciones.

Referencia

:

Certificación CE de los Equipos de Caudal Másico

Fecha

:

Enero-1996.

Los equipos de  Brooks (eléctricos/electrónicos) en relación con la marca  CE han pasado satisfactoriamente las
pruebas referentes a las regulaciones de Compatibilidad Electro magnética (EMC directiva 89/336/EEC).
Sin embargo se requiere una atención especial en el momento de seleccionar el cable de señal cuando se va a
utilizar un equipo con marca CE

Calidad del cable de señal, prensaestopas y conectores:

Brooks suministra cable(s) de alta calidad, que cumple las especificaciones de la certificación CE .
Si usted adquiere su propio cable de señal, debería usar un cable que esté  completamente protegido en su
conjunto con un apantallamiento del 100%.
Cuando utilice conectores del tipo “D” ó “Circular” deberían estar protegidos con una pantalla metálica. Cuando
sea posible, se deberán utilizar prensaestopas metálicos provistos de abrazadera para la pantalla del cable.
La pantalla del cable  deberá ser  conectada al casquillo metálico ó prensa y  protegida  en ambos extremos
completamente en los 360 Grados.
La pantalla deberá conectarse a tierra.
Los conectores  estandar de tipo tarjeta (Card Edge) no son  metálicos, los cables utilizados  deberán ser
protegidos con un apantallamiento del 100% para cumplir con la certificación CE.
La pantalla deberá conectarse a tierra.
Para ver la configuración de los pines: Por favor, consultar  Manual de Instrucciones adjunto.

Содержание 0154

Страница 1: ...tion and Operation Manual X SE 0152 0154 eng PartNumber 541C052AAG March 2008 Brooks Models 0152 0154 5 Gas and Liquid Mass Flow Secondary Electronics Brooks Model 0154 Four Channel Read Out Table Top...

Страница 2: ...proper electrical and pressure sources To ensure proper performance use qualified personnel to install operate update program and maintain the product When replacement parts are required ensure that...

Страница 3: ...and chemicals to medical devices analytical instrumentation semiconductor manufacturing and more The Brooks product you have just received is of the highest quality available offering superior perform...

Страница 4: ...Installation and Operation Manual X SE 0152 0154 eng PartNumber 541C052AAG March 2008 Brooks Models 0152 0154 THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Страница 5: ...sit Precautions 2 2 2 6 Removal from Storage 2 2 2 7 Dimensions of the Enclosures 2 2 2 8 Ventilation and Mounting Requirements 2 3 2 9 Cleaning Instructions 2 3 2 10 Cable Requirements 2 3 2 11 Conne...

Страница 6: ...tte 1 4 1 4 Mounting of 1 2 19 Cassette into 19 Rack 1 4 1 5 Mounting of Panel Mount Unit with Dimensions for the Panel Cut Out 1 5 1 6 Electrical Configuration 1 6 2 1 Back Panel Layout 2 4 2 2 Main...

Страница 7: ...neering units rather than full scale 1 5 Vdc or 4 20 mA I O cannot be used Each channel can be operated as master or slave or in an independent control mode Valve override functions are selectable In...

Страница 8: ...int input and output signal up to 4 channels One 15 pin D connector for connecting remote valve override control function One 9 pin D connector for RS232 communication link to a PC Display reading Mod...

Страница 9: ...152 0154 Section 1 Introduction Installation and Operation Manual X SE 0152 0154 eng Part Number 541C052AAG March 2008 Figure 1 1 Dimensions Table Top Models 0152 0154 Figure 1 2 Dimensions Panel Moun...

Страница 10: ...Panel Mount Option Bracket Set The dimensions of the 1 2 19 cassette are cassette 3HE x 42TE using three different parts Table Top Option Table Top Housing 19 Rack Option 19 Rack Panel Mount Option Br...

Страница 11: ...mber 541C052AAG March 2008 The panel mount option uses the cassette mounted into a panel using the panelmount bracket set The dimensions for the panel cutout and the mounting details are Figure 1 5 Mo...

Страница 12: ...1 6 Brooks Models 0152 0154 Section 1 Introduction Installation and Operation Manual X SE 0152 0154 eng Part Number 541C052AAG March 2008 Figure 1 6 Electrical Configuration...

Страница 13: ...eries 5850 5860 and Pressure Control series 5866 the following cables are available Via the Netherlands Length 3 m 9 84 ft part number 124Z236AAA Length 6 m 19 69 ft part number 124Z237AAA Length 12 m...

Страница 14: ...th 10ft 3m part number 124Z907ZZZ Length 25ft 7m part number 124Z908ZZZ Length 50ft 15m part number 124Z909ZZZ 1 3 5 RS 232 Communication For connecting the Model 0152 0154 to a personal computer an R...

Страница 15: ...Instrument Brooks Instrument Neonstraat 3 1 4 4 Kitasuna Koto Ku 6718 WX Ede Netherlands Tokyo 136 0073 Japan P O Box 428 Tel 011 81 3 5633 7100 6710 BK Ede Netherlands Fax 011 81 3 5633 7101 Tel 31 3...

Страница 16: ...ax 011 81 3 5633 7101 Tel 31 318 549 300 Email BrooksAs EmersonProcess com Fax 31 318 549 309 E mail BrooksEu EmersonProcess com All flow instruments returned to Brooks requires completion of Form RPR...

Страница 17: ...quirements For compliance with the EMC directive 89 336 EEC the equipment has to be installed with shielded signal cables which are overall completely screened with a shield of at least 80 Sub D conne...

Страница 18: ...the instrument Remove the fuses by pulling out the fuse cartridge The fuses must be replaced by fuses meeting the following requirements Dimensions 5 x 20mm Current 2A T slow blow Voltage Suitable for...

Страница 19: ...ination 24 Vdc and power ground 15 Vdc only combination 15 Vdc and 15 Vdc When applying non Brooks cables for use of Digital MFC M s incl MF on mA I O pin 3 and 5 should be shorted at the read out sid...

Страница 20: ...hannel 4 11 Input Remote setpoint Volt channel 3 12 nc nc 13 Input Remote setpoint Volt channel 4 14 Flow ground channel 1 15 Input Remote setpoint mA channel 1 16 Flow ground channel 2 17 Input Remot...

Страница 21: ...otentiometers is necessary The microprocessor board uses 0 5 Vdc signals internally As a result Flow or Pressure inputs other than 0 5 Vdc are first converted by the optional I O board from either 0 1...

Страница 22: ...before installing the optional I O board 2 X denotes the channel number to which the jumper relates eg for channel 1 X 1 3 For i series 2 3 For Flomega and pressure series 1 2 For digital series 1 2...

Страница 23: ...the Enter key If the confirmation takes too long after a change of any setting the display will return automatically to its flow read out function The only exception to this rule are adjustments in th...

Страница 24: ...all changed settings For example confirmation of selected setpoint value master channel blending remote or local valve function valve control certain menu selections display layout or engineering unit...

Страница 25: ...ing the Active Channel On the display the flow information of the different channels is displayed After power up channel 1 is always active This is indicated on the display by an character after the c...

Страница 26: ...row up down keys change the setpoint in steps of 2 of full scale The single arrow up and down keys change the setpoint in steps of 0 1 of full scale The setpoint after power up is determined in the Se...

Страница 27: ...master NOTE The flow of the slave channel is determined by the flow of the master channel and therefore the setpoint value of the slave may not correspond with the current flow or pressure at the slav...

Страница 28: ...ter confirmation with Enter the following is displayed V opens the valve to purge the system V closes the valve and shuts off the flow After confirmation of V0 the Valve Override function will be disa...

Страница 29: ...he controller is Remote controlled When using Volt I O it is possible to view the flowrate at the display during remote control When using mA I O this is not possible The remote function will be activ...

Страница 30: ...le to represent the setpoint or flow All available engineering units are given in Appendix A After activation of Change Eng Units the following screen is displayed The engineering units per channel ar...

Страница 31: ...9 999 as a maximum Display Format As shown in the Full Scale Value screen it is possible to change the amount of decimal places on the display This can be done in the menu selection Display format Whe...

Страница 32: ...his case the Enter button can be used to change the change engineering unit to a time related unit Menu Leave the totalizer display function If totalizer is active running mode this is noticed on the...

Страница 33: ...oint Adjusting one of these alarms is done in three steps Step 1 select the line of the alarm by using the up and down buttons Step 2 press Enter and select alarm ON or OFF by using the up and down bu...

Страница 34: ...1 and 2 are selected for 0 5 volts or 0 20 mA channel 3 and 4 are selected for 1 5 Volts or 4 20 mA Input Output range selection In this software version change the Input Output is selectable for a ra...

Страница 35: ...file is a LLB format Both application versions handle the full capacity to control the connected devices The available parameters to be used for controlling the connected devices are setpoint flow and...

Страница 36: ...4 2 Brooks Models 0152 0154 Section 4 Operation Via Personal Computer Installation and Operation Manual X SE 0152 0154 eng Part Number 541C052AAG March 2008 Figure 4 2 Testpoint...

Страница 37: ...min mls h mln s mln min mln hl s l min l h ls s ls min ls h ln s ln min ln h cm 3 s cm 3 min cm 3 h cm 3s s cm 3s min cm 3s h cm 3n s cm 3n min cm 3n h m 3 s m 3 min m 3 h m 3s s m 3s min m 3s h m 3n...

Страница 38: ...A 2 Brooks Models 0152 0154 Appendix A Engineering Units Installation and Operation Manual X SE 0152 0154 eng Part Number 541C052AAG March 2008 THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Страница 39: ...unit 20 l min 100 Full Scale Determination of entered setpoint 50 Blending ratio is 5 10 bar bar Setpoint slave 5 x 15 bar 75 bar Example 1 Master channel flow is 80 l min Slave channel flow has to b...

Страница 40: ...B 2 Brooks Models 0152 0154 Appendix B Blending Examples Installation and Operation Manual X SE 0152 0154 eng Part Number 541C052AAG March 2008 THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Страница 41: ...venlig hilsen Deutsch Brooks Instrument 407 West Vine St Hatfield PA 19440 U S A Subject Nachtrag zur Bedienungsanleitung Referenz CE Zertifizierung f r Massedurchflu ger te Datum Januar 1996 Nach er...

Страница 42: ...Please refer to the enclosed Instruction Manual Espa ol Brooks Instrument 407 West Vine St Hatfield PA 19440 U S A Asunto Addendum al Manual de Instrucciones Referencia Certificaci n CE de los Equipo...

Страница 43: ...il portant le label CE Qualit du c ble des presse toupes et des connecteurs Brooks fournit des c bles de haute qualit r pondant aux sp cifications de la certification CE Si vous approvisionnez vous m...

Страница 44: ...aad van 100 om te voldoen aan de CE certificering Het scherm moet worden verbonden met aarde Voor pin configuraties a u b verwijzen wij naar het bijgesloten instruktie handboek Hoogachtend Italiano Br...

Страница 45: ...sk jord p riktig pinne i pluggen for m te CE sertifiseringskrav For tilkobling av medleverte plugger vennligst se h ndboken som h rer til utstyret Vennlig hilsen Portugu s Brooks Instrument 407 West V...

Страница 46: ...a maadoitettu Nastojen liitt minen katso liitteen oleva manuaali Yst v llisin terveisin Svensk Brooks Instrument 407 West Vine St Hatfield PA 19440 U S A Subject Addendum to the Instruction Manual Ref...

Страница 47: ...Brooks Models 0152 0154 Installation and Operation Manual X SE 0152 0154 eng Part Number 541C052AAG March 2008 THIS PAGE WAS INTENTIONALLY LEFT BLANK...

Страница 48: ...PORT Brooks Instrument provides sales and service facilities around the world ensuring quick delivery from local stock timely repairs and locally based sales and service facilities Our dedicated flow...

Отзывы: