background image

 

 

WARNING! 

 

IMPORTANT SAFETY INSTRUCTIONS 

IMPROPER USAGE CAN LEAD TO SEVERE INJURY OR DEATH 

READ AND FOLLOW ALL INSTRUCTIONS 

 

 

Commercial/Industrial swinging door operator

 for trained traffic* use only.  The manufacturer of this product does not include 

external safety devices as a standard feature.  Since Entrapment shall be compliant with UL 325 Section 29.4, the addition of 
external safety devices on swinging door operators is considered redundant.  If external safety devices are to be added to this 
operator, refer to the Terminal Strip Hookup in this manual for proper wiring and to the owner’s manual of the external safety 
device manufacturer for proper installation and use.    

  No person shall perform any service or activate this door operator unless they have been properly trained in its safe usage and 

have read the owner’s manual. 

  Never let children operate or play with door controls. 

  Before activating this door operator, check the following: 

1.  Assure that all personnel are clear of the path of this operator and the door that it is attached to. 
2.  Assure that all fingers, hands, feet, limbs and articles of clothing are clear of all moving parts and pinch points. 

  Personnel should keep away from a door in motion and keep the moving door in sight until it is completely closed or open.  NO 

ONE SHOULD CROSS THE PATH OF A MOVING DOOR. 

  Test the door’s safety features at least once a month.  After adjusting either the force, speed or the limit of travel, retest the door 

operator’s safety features. Failure to do so may cause severe injury or death. 

  KEEP DOORS PROPERLY OPERATING AND BALANCED.  Refer to door manufacturer’s manual.  Have repairs done by 

trained technicians. 

  Prior to performing any service on this product (including the replacement of any fuses or circuit breakers), disconnect the 

operator from the supply voltage. 

  For continued protection against fire, replacement fuses or circuit breakers shall be of the same type and ratings as those being 

replaced. 

*Defined in ANSI 156.10 as a controlled group of people trained in the safe use and operation of a particular door installation. 

SAVE THESE INSTRUCTIONS 

Содержание NB-2000-HD2

Страница 1: ...brookfield industries inc Commercial Industrial Door Operator Installation Instructions C 99 W Hillside Ave Thomaston CT 06786 P 860 283 6211 F 860 283 6123 www bfimfg com info bfimfg com NB 2000 HD2...

Страница 2: ...1of this manual Assure all electrical wiring and grounding is installed as specified in this manual and as required by any local codes Proper installation can also reduce the risk of electrical shock...

Страница 3: ...that all personnel are clear of the path of this operator and the door that it is attached to 2 Assure that all fingers hands feet limbs and articles of clothing are clear of all moving parts and pinc...

Страница 4: ...eset by brookfield industries inc however we recommend these values be double checked with the Parameter sheet supplied 7 Install activation switches or push button stations a within sight of the door...

Страница 5: ...ead Door or Follow Door on the next screen Fig 5 then skip to step 5 Fig 2 Fig 3 Fig 4 Fig 5 4 Selecting Standard will give you the screen shown in Fig 6 Choose the appropriate serial number series of...

Страница 6: ...t Inputs to display the Input Diagnostic Screen Fig 10 Fig 10 The buttons down the left side represent an actual input to the PLC All standard Operator functions can be tested using these buttons The...

Страница 7: ...select Lead or Follow Door on the next screen then skip to step 6 4 For Standard operator choose the appropriate ship date of the operator on the next screen 5 You ll be given a display of the first t...

Страница 8: ...ose Enable preset to the Door Position value plus 30 units i e if the Door Position is 310 set the Auto Close Enable to 340 Note Some installations may require slightly higher lower values for best re...

Страница 9: ...2 77 82 86 90 94 84 64 71 77 84 90 95 100 105 110 96 73 81 89 96 103 109 115 120 125 PER ANSI 156 10 For weights and widths not listed TIME DOOR WIDTH X DOOR WEIGHT 1 2 188 Minimum Opening Time second...

Страница 10: ...10VAC THRU LEFT SIDE OF COVER 4 1 2 DIA THRU HOLES FOR 3 8 DIA GRADE 5 BOLTS TYP 6 PLACES TYP 2 PLACES FRONT ELEVATION SIDE ELEVATION L 110 VAC INPUT SPA CER REFERENCE LEGEND INSIDE COVER SPEED BOARD...

Страница 11: ...1 F E D 2 3 C B A 1 2 3 4 Date Material 6 7 Scale 8 F D E Checked by Drawn by Decimal Fractional Angular Tolerances 5 Revision note 6 Rev 7 B C Notes A Date Sign 8 Check...

Страница 12: ...NE FRONT ELEVATION SIDE ELEVATION SPEED BOARD LEGEND BRACKET DETAIL 1 F E D 2 3 C B A 1 2 3 4 Date Material 6 7 Scale 8 F D E Checked by Drawn by Decimal Fractional Angular Tolerances 5 Revision note...

Страница 13: ...6 4 294 4 1 1 5 6 1 4 4170 25 24 5 6 24 5 6 25 24 5 6 25 25 8 02765 8 176276 6 4 0 564 2 11 72 1 1 0 0 176 8 0 9 4 9 55 8 10 4 52 4 4 1 0 24 5 6 0 0276 CVG RRTQXGF D FCVG CVGTKCN brookfield industrie...

Страница 14: ......

Страница 15: ...ging Door Operator Information contained herein is exclusive property of brookfield industries inc and may not be duplicated in part or in whole without written consent Line Note 10 Review Page 2 for...

Страница 16: ...ators reverse M1 M2 at motor 11 When using receptacle style chargers ue GFC I type 12 Provides auto open during power loss 13 Additional N terminal block for battery backup only For 220 VAC Power See...

Страница 17: ...ic opening during power loss The battery backup system is an optional addition Relay 110 220 VAC Input IPDT 6A Output Note 9 NEMA Enclosure A2 14 Note 16 12 11 A1 Spacer 1 1 1 1 3 3 9 9 10 10 11 11 12...

Отзывы: