Notes:
1.Use 15 Amp/110/220 VAC; Circuit Breaker
2.Use 1 Amp/110/220 VAC slow-blow; Circuit Breaker
3.Class (2) 24 VDC Terminals: Power Supply: (Com & 3)
Inputs: 9-14 & 17-22
4.All 110/220 AC wires shall be minimum 14 AWG & (105° C, 300 V)
5.All 12-24 VDC (non-motor) wires shall be minimum 20 AWG & (105° C, 300 V)
6. All motor wires shall be minimum 12 AWG & (105° C, 300 V) and 25' max. length
7. Use 8 Amp/110/220 VAC slow-blow; Circuit Breaker
8. Wire as shown for normal direction, reverse 1&3 for opposite direction and reset transducer to 320 at
new home position
9. For normal direction wire M1 & M2 as shown. To reverse direction, switch black wire to M2 & white wire
to M1.
DO NOT ALTER BATTERY BACKUP WIRING
10. Install Ferrite Core Red Lion FCOR (2 turns=440 ohm @ 25 MHz) on all incoming AC and DC voltage
lines
11. Part must be changed to utilize 220 VDC power
V3.8, P-2
Legend:
Pink solid line designates a WHITE wire.
Transducer Wiring:
Wire as shown for : RH Operator (pull open), LH Operator (push open), LH Door Mounted
Reverse 1 & 3 for : RH Operator (push open), LH Operator (pull open), RH Door Mounted
(Optional)
Non-contact Presence Sensor (N.O.)
This devices is 'additional' or 'redundant'
(Required Device)
(N.O.) Reversing Edge Switch (contact type)
Fail Safe External Entrapment Devise
Meeting requirements of UL 325 30.2 in
order to Close Door this Devise MUST be
Wired as Shown
24 VDC
-
+
FS1
FS3
FS2
FS4
(Fail Safe)
4-Wire Adapter
2-Wire Tape Switches
Daisy Chain Connection of 4-Wire Tape Switches
Adapting Existing 2-Wire Tape Switch to 4-Wire Connection
Presence Sensor
FS4
FS4
FS3
FS3
19
19
20
20
21
21
22
22
No
te
: 7
1
1
1
1
3
3
9
9
10
10
11
11
12
12
13
13
14
14
15
15
16
16
FS1
FS1
FS2
FS2
1
2
3
4
1
3
2
4
FS1
FS3
FS2
FS4
1
1
2
2
1
2