Motor Control Trimpot Settings
(Approximate)
:
Upper Board (Multi Speed)
PRESET 1:
Creep Close (REV) Speed POT 50%*
PRESET 2:
Creep Open (FWD) Speed POT 50%*
PRESET 3:
Close (REV) Speed POT
80%*
PRESET 4:
Open (FWD) Speed POT
80%*
*approximate time to open
!
20 seconds, to partial
!
8 seconds, to close
!
20
seconds
Lower Board
DB
50%
RESP
50%
IR
50%
RCL
50%
FCL
50%
MAX
100%
FACC
20%
RACC
20%
Reversing Direction:
Can be accomplished by (2) methods:
Method 1)
Physically rotate the operator 180 degrees by placing the motor end to the
transducer end and the transducer end to the motor end.
Method 2)
1. With the door in the new home or closed position, reset the
Rotary
Position Transducer
to 320.
2. On the
Rotary Position Transducer
: Move the green and white wire to
terminal 1 and the black wire to terminal 3.
3. On the
Motor Control
:
switch the black wire to M2 and the white wire to
M1. Do not change the battery backup wiring.