17
8.
Basic settings ex works
(continuation)
Function number Meaning and possible settings
4
Automatic switch-off in battery operation (see chapter 13)
Power pack switches off automatically after a selectable waiting
time. Setting ex works: 10 min.
By pressing the flash energy regulation keys "up/down" select the
desired time duration between 10 min. and 99 min. Setting 0 =
automatic mode deactivited
5
Sensitivity of photocell (see chapter 5)
Setting ex works "on": both photocells are switched on
By pressing the flash energy regulation keys "up/down", the
photocell with the higher sensitivity can be switched off. Through
this the sensitivity of the photocell will be reduced overall. In this
mode the LCD display shows the value "--".
6
Flash counter
Figure group in the digital display:
XX
xxxx
= standard display
Figure group in the digital display: xx
XX
xx
= after activating the energy control key "down"
Figure group in the digital display: xxxx
XX
= after activating the energy control key "down"
7
Delivery date: month
8
Delivery date: year
9
Series number of the unit:
Figure group in the digital display:
XX
xx
10
Series number of the unit:
Figure group in the digital display: xx
XX
11
Brightness ready signal (see chapter 6)
Setting ex works: "--"
This function reduces the brightness of the ready display. If the
function is activated, the LCD display shows the value "on".
Содержание Verso A2 plus
Страница 5: ...5 also valid for Verso A4 ...