11
less, P5 for 400 J and less. Thus the brightness of the modelling light can be
increased.
"HI"
All lamp bases operate at full modelling light power independent of flash output.
"LO"
Lighting level is reduced for all lamps independent of the flash output to reduce
power consumption and extend the service life of the halogen lamps.
Pressing the "mod" key (14) (1 sec. long) when the modelling lamp is on, will give direct
access to the "HI" mode. To return to the previous mode briefly press "mod" again.
Highest possible proportionality settings when combining units of different output:
Nano 2
Verso A2
Topas A2
Grafit 2, A2
Mobil
Nano A4
Topas A4
Grafit A4
Verso A4
Topas A8 Evolution
Nano 2
Verso A2
Topas A2
Grafit 2, A2
Mobil
P3
(or "P" using only
Verso A2 / Nano 2)
P2
P1
Nano A4
Topas A4
Grafit A4
Verso A4
P2
P2
(or "P" using
Verso A4 / Nano A4)
P1
Topas A8 Evolution P1
P1
P1
Example 1: A power pack Verso A4 is operated together with a power pack Topas A8
Evolution. The modelling light is proportional when both are set to mode
"P1".
Example 2: A power pack Verso A2 is operated with a Nano 2. The modelling light is
proportional and most intense when both are set to mode "P".
4.3
Modelling light in battery operation
In battery operation the lamp bases Pulso G and Unilite can be equipped with the
following halogen lamps:
Maximum power of modelling light with mains voltage 200 - 240 V:
Halogen
1 x 650 W / 2 x 300 W / 3 x 150 W
Maximum power of modelling light with mains voltage 100 - 120 V:
Halogen
2 x 300 W / 3 x 150 W
If lamp bases with a higher total rating are connected, they switch off.
The unit Power Dock is equipped with a converter, which converts the 36 V voltage of
the battery package, depending on the local available voltage, automatically into a
mains voltage of 200
– 240 V resp. 100 – 120 V. The mains voltage can be modified
manually if desired (see chapter 8).