background image

12

13

www.bromicheating.com

www.bromicheating.com

For longest product life & to maintain product appearance 
mount heater under cover & protect from rain & weather 
whenever possible.
The exterior housing of the heater should be cleaned 
regularly with a soft damp cloth. For locations near the 
coast, salt in the air can cause rusting of metal. Additional 
cleaning of the heater with a soft damp cloth fortnightly will 
increase the life of the products appearance.
Ensure that there is no excessive build-up of dirt/dust on 
the reflectors or elements as this can cause overheating 
and premature element failure. To clean the reflectors and 
elements, ensure heater is off and has been off for at least 2 
hours after operation, and wipe off any dirt/dust with a soft 
& dry cloth.

MAINTENANCE 

SERVICING

TUBE ELEMENT REPLACEMENT

WARNING

ELECTRICAL SHOCK HAZARD!
Serious injury or death may occur.
Disconnect from electrical supply before servicing this 
heater.

!

!

WARNING

Servicing and maintenance MUST be carried out by an 
authorised and licensed person only

1.  Remove Front Cover of the heater by unscrewing the 3 

screws holding it in place. 
 

2.  Remove first Element End Cover by unscrewing the 2 

screws holding it in place. 
 

3.   Open first Element Lock Bracket by removing screw. 

 

4.  Remove outer Hex Nut, Spring Washer and Lead Wire 

Ring Terminal from the threaded stud. 
 

5.  Repeat steps 2-4 to release second end of element.  

 

6.  Remove old Tube Element. 

 
 

7.  Assemble new Tube Element. 

Hex Nut, Spring Washer and Ring Terminal must be 
assembled tightly at both ends of element. 
 
 

8.  Element Lock Brackets and Element End Covers must 

be replaced at both ends of the heater. Assemble front 
cover and secure with 3 screws.

REPLACEMENT PART LIST

No.

Description

BH0420006 

(2000W)

BH0420007 

(3000W)

BH0420008 

(4000W)

BH0420009 

(6000W)

1

Tube Element

BH8180001

BH8180002

BH8180001

BH8180002

2

Front Cover

BH8180003

BH8180004

BH8180003

BH8180004

3

Element End Cover Set

BH8180005

BH8180006

BH8180005

BH8180006

4

Junction Box Cover & Seal Set

BH8180007

BH8180007

BH8180007

BH8180007

5

Mounting Bracket Set (Short)

BH8180008

BH8180008

BH8180008

BH8180008

6

Mounting Bracket Set (Long)

BH8180009

BH8180009

BH8180009

BH8180009

7

Tube Suspension Kit

BH8180012

BH8180012

BH8180012

BH8180012

8

Chain Suspension Kit

BH8180013

BH8180013

BH8180013

BH8180013

SYMPTOM

POSSIBLE CAUSE (S)

CORRECTIVE ACTION

Element does not energize

1. Defective element
2. Improper connection

1. Replace element
2. Check connection to power 
outlet

Not enough heat

1. Heater too small for application
2. Heater mounted too high or too 
far

1. Add additional heater(s)
2. Decrease mounting height or 
distance

Too much heat

1. Heater too large for application
2. Heater mount too low or too close

1. Replace with smaller heater
2. Increase mounting height or 
distance

Hot spot in Tube

1. Heater is not level
2. Grease or moisture on tube

1. Adjust to level mount
2. Clear tube-replace if problem 
persists

TROUBLESHOOTING

4000W & 6000W Models

2000W & 3000W Models

4000W & 6000W Models

2000W & 3000W Models

1.

2.

3.

4.

Version 1.0ES

Revised: 04/09/2013

Содержание Tungsten 2000W

Страница 1: ...N ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE IMPORTANT TUNGSTEN SMART HEAT ELECTRIC HEATER BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS TUNGSTEN 2000W 3000W 4000W AND TUNGSTEN 6000W Version 1 5 EU ...

Страница 2: ...S 7 CEILING WALL MOUNTING 8 CHAIN SUSPENSION 8 TUBE SUSPENSION 9 ELECTRICAL INSTALLATION 10 WIRING DIAGRAMS 11 SERVICING 12 MAINTENANCE 12 TUBE ELEMENT REPLACEMENT 12 REPLACEMENT PART LIST 13 TROUBLESHOOTING 13 BROMIC HEATING Head Office 1 Suttor Street Silverwater Sydney NSW 2128 Australia Telephone 1300 276 642 within Australia or 61 2 9748 3900 from overseas Fax 61 2 9748 4289 Email info bromic...

Страница 3: ... plug and the permanence of the warning tag shall be determined in accordance with Test for Permanence of Cord Tag Section 53 This Installation Operation and Service manual should not be removed from the site of installation Installer should leave manual with the customer for future reference Any guard or other protective device removed for servicing conducted by an authorised person must be repla...

Страница 4: ... FLOOR 3 0 110 12 13 18 12 6 WARNING DO NOT MOUNT THE HEATER VERTICALLY Heater MUST be installed so that the tube elements are horizontal Failure to do this will cause the heating element within the tube to sag and cause premature burnout Installing vertically will void the manufacturers warranty WARNING DO NOT MOUNT THE HEATER VERTICALLY For outdoor installation heater must be mounted with face o...

Страница 5: ...ed 2 Heater must be installed with heater surface at least 2400mm above the floor level Supplied suspension tubes position heater surface 1000mm below the ceiling surface If required cut down length of suspension tubes to ensure correct installation height Minimum distance from front surface of heater to ceiling surface must be 250mm for 2000W 3000W models 330mm for 4000W 6000W models 3 If suspens...

Страница 6: ... for at least 105 C 3 For supply connection use wires suitable for at least 105 C and at least 1 5mm2 for 2000W and 3000W models 2 5mm2 for 4000W and 6000W models The fixed wiring must be positioned away from protect ed from the enclosure of the heater 4 Make electrical connections in accordance with local electrical code regulations For outdoor installation WARNING ELECTRICAL SHOCK HAZARD Serious...

Страница 7: ...Element 7 Assemble new Tube Element Hex Nut Spring Washer and Ring Terminal must be assembled tightly at both ends of element 8 Element Lock Brackets and Element End Covers must be replaced at both ends of the heater Assemble front cover and secure with 3 screws REPLACEMENT PART LIST No Description BH0420006 2000W BH0420007 3000W BH0420008 4000W BH0420009 6000W 1 Tube Element BH8180001 BH8180002 B...

Отзывы: