IMPORTANT

This manual contains important information about the installation, operation, and maintenance 

of Tungsten Smart-Heat™ Electric Heaters. Please pay close attention to the important safety 

information shown throughout this instruction manual. Any safety information will be accompanied 

by the following safety alert symbols:

DANGER,        WARNING,        IMPORTANT

•  READ THIS MANUAL CAREFULLY before installing or 

servicing this product.

•  Improper installation, operation, or maintenance can result in 

death, severe injury, or property damage. 

•  This appliance is intended for fixed installation with 220-

240Volt power supply.

•  Installation MUST be carried out by a licensed and authorised 

technician in accordance with local electrical codes.

•  Patent Pending & Australian Registered Design 338721

!

!

!

CONTENTS

IMPORTANT NOTES & WARNINGS

4

PRODUCT OVERVIEW

5

PRODUCT DESCRIPTION AND FEATURES

5

SPECIFICATIONS

5

HEATER INSTALLATION

6

REMOVE PACKAGING MATERIAL

6

INSTALLATION CLEARANCES

7

CEILING WALL MOUNTING

8

CHAIN SUSPENSION

8

TUBE SUSPENSION

9

ELECTRICAL INSTALLATION

10

WIRING DIAGRAMS

11

SERVICING

12

MAINTENANCE

12

TUBE ELEMENT REPLACEMENT

12

REPLACEMENT PART LIST

13

TROUBLESHOOTING

13

BROMIC HEATING 

Head Office: 

1 Suttor Street, Silverwater, Sydney, NSW 2128 Australia    

Telephone:

 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas)  

Fax:

 +61 2 9748 4289   

Email:

 [email protected]   

Web:

 www.bromicheating.com 

Note:  Bromic Heating reserves the right to make changes to specifications, parts, components and equipment without prior notification. 

This Installation, operation and service manual may not be reproduced in any form with prior written consent from Bromic Heating. 

Correct Disposal of this product

This marking indicates that this product should not 
be disposed with other household wastes throughout 
the EU. To prevent possible harm to the environment 
or human health from uncontrolled waste disposal, 
recycle it responsibly to promote the sustainable reuse 
of material resources. To return your used device, 
please use the return and collection systems or contact 
the retailer where the product was purchased. They 
can take this product for environmental safe recycling.

Содержание Tungsten 2000W

Страница 1: ...N ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE IMPORTANT TUNGSTEN SMART HEAT ELECTRIC HEATER BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS TUNGSTEN 2000W 3000W 4000W AND TUNGSTEN 6000W Version 1 5 EU ...

Страница 2: ...S 7 CEILING WALL MOUNTING 8 CHAIN SUSPENSION 8 TUBE SUSPENSION 9 ELECTRICAL INSTALLATION 10 WIRING DIAGRAMS 11 SERVICING 12 MAINTENANCE 12 TUBE ELEMENT REPLACEMENT 12 REPLACEMENT PART LIST 13 TROUBLESHOOTING 13 BROMIC HEATING Head Office 1 Suttor Street Silverwater Sydney NSW 2128 Australia Telephone 1300 276 642 within Australia or 61 2 9748 3900 from overseas Fax 61 2 9748 4289 Email info bromic...

Страница 3: ... plug and the permanence of the warning tag shall be determined in accordance with Test for Permanence of Cord Tag Section 53 This Installation Operation and Service manual should not be removed from the site of installation Installer should leave manual with the customer for future reference Any guard or other protective device removed for servicing conducted by an authorised person must be repla...

Страница 4: ... FLOOR 3 0 110 12 13 18 12 6 WARNING DO NOT MOUNT THE HEATER VERTICALLY Heater MUST be installed so that the tube elements are horizontal Failure to do this will cause the heating element within the tube to sag and cause premature burnout Installing vertically will void the manufacturers warranty WARNING DO NOT MOUNT THE HEATER VERTICALLY For outdoor installation heater must be mounted with face o...

Страница 5: ...ed 2 Heater must be installed with heater surface at least 2400mm above the floor level Supplied suspension tubes position heater surface 1000mm below the ceiling surface If required cut down length of suspension tubes to ensure correct installation height Minimum distance from front surface of heater to ceiling surface must be 250mm for 2000W 3000W models 330mm for 4000W 6000W models 3 If suspens...

Страница 6: ... for at least 105 C 3 For supply connection use wires suitable for at least 105 C and at least 1 5mm2 for 2000W and 3000W models 2 5mm2 for 4000W and 6000W models The fixed wiring must be positioned away from protect ed from the enclosure of the heater 4 Make electrical connections in accordance with local electrical code regulations For outdoor installation WARNING ELECTRICAL SHOCK HAZARD Serious...

Страница 7: ...Element 7 Assemble new Tube Element Hex Nut Spring Washer and Ring Terminal must be assembled tightly at both ends of element 8 Element Lock Brackets and Element End Covers must be replaced at both ends of the heater Assemble front cover and secure with 3 screws REPLACEMENT PART LIST No Description BH0420006 2000W BH0420007 3000W BH0420008 4000W BH0420009 6000W 1 Tube Element BH8180001 BH8180002 B...