www.bromicheating.com

www.bromicheating.com

Junction Box

AC

Heater Element 1

240 V AC

SINGLE PHASE

EARTH 

WIRE

WARNING

240 V AC Single Phase

Heater must be permanently 

installed and hard wired by an 

authorised/licenced person.

WARNING

240 V AC Single Phase

Heater must be permanently 

installed and hard wired by an 

authorised/licenced person.

WARNING

240 V AC Single Phase

Heater must be permanently 

installed and hard wired by an 

authorised/licenced person.

Junction Box

AC

Heater Element 1

240 V AC

SINGLE PHASE

EARTH 

WIRE

Heater Element 2

WIRING DIAGRAM

TUNGSTEN SMART-HEAT ELECTRIC

OPTIONAL INSTALLATION

4000W & 6000W MODELS

Junction Box

AC

Heater Element 1

240 V AC

SINGLE PHASE

AC

240 V AC

SINGLE PHASE

EARTH 

WIRE

Heater Element 2

WIRING DIAGRAM

TUNGSTEN SMART-HEAT ELECTRIC

STANDARD INSTALLATION

4000W & 6000W MODELS

WIRING DIAGRAM

TUNGSTEN SMART-HEAT ELECTRIC

STANDARD INSTALLATION

2000W & 3000W MODELS

ELECTRIC AL INSTALLATION 

CONTINUED...   

!

 

WARNING

This Heater MUST be permanently Installed and hard 
wired by an authorised/licenced person. Do Not perform 
maintenance, or carry out installation or assembly 
procedure while electrical power is switched on.

1.  Check product label for correct voltage and wattage 

- Make sure power source conforms to the heaters 
requirements.

2.  Junction box has a Ø22mm hole to suit M20 or 

PG13.5 cord grip. Install cord grip with minimum rat-
ing of IPX4 to maintain the IPX4 rating of the heater. 
Use cord grip suitable for at least 105°C.

3.  For supply connection, use wires suitable for at least 

105°C and at least 1.5mm2 for 2000W and 3000W 
models, 2.5mm2 for 4000W and 6000W models. The 
fixed wiring must be positioned away from & protect-
ed from the enclosure of the heater.

4.  Make electrical connections in accordance with local 

electrical code regulations. For outdoor installation 

WARNING

ELECTRICAL SHOCK HAZARD! Serious injury or death may 

occur. Disconnect from electrical supply before installing or 

servicing this heater. Read and follow installation clearance 

requirements outlined in this manual. The Appliance MUST 

be connected to a properly grounded electrical source. 

Disconnection incorporated in the fixed wiring is to be 
provided

!

ELECTRICAL INSTALLATION

all connections must be made in accordance with local 
electrical code regulations for outdoor wiring. Only 
use wiring components approved for outdoor use with 
minimum IPX4 rating.  For all models the junction box has 
one terminal block for the active and neutral connections 
of the element. The polarity of power supply can be 
connected to terminal block in either direction. Earth 
ground wire screw is located in the end of junction box.

5.  After installation, the distance between live parts and 

earth (or earthed metal) should not be less than 2.5 mm. 
The distance between live and neutral terminal should not 
be less than 2.0 mm.

6.  Assemble the junction box cover & gasket. Ensure that 

the junction box cover gasket (supplied with unit) is 
installed to maintain the IPX4 water ingress protection 
rating of the heater. Failure to install correctly will void the 
manufacturer’s warranty.

ELECTRICAL INSTALLATION 

6

1

2

4

Содержание Tungsten 2000W

Страница 1: ...N ABOUT THIS MANUAL KEEP INSTRUCTION WITH APPLIANCE FOR FUTURE REFERENCE IMPORTANT TUNGSTEN SMART HEAT ELECTRIC HEATER BY BROMIC INSTALLATION INSTRUCTION AND SERVICE MANUAL SUITABLE FOR ELECTRIC HEATER MODELS TUNGSTEN 2000W 3000W 4000W AND TUNGSTEN 6000W Version 1 5 EU ...

Страница 2: ...S 7 CEILING WALL MOUNTING 8 CHAIN SUSPENSION 8 TUBE SUSPENSION 9 ELECTRICAL INSTALLATION 10 WIRING DIAGRAMS 11 SERVICING 12 MAINTENANCE 12 TUBE ELEMENT REPLACEMENT 12 REPLACEMENT PART LIST 13 TROUBLESHOOTING 13 BROMIC HEATING Head Office 1 Suttor Street Silverwater Sydney NSW 2128 Australia Telephone 1300 276 642 within Australia or 61 2 9748 3900 from overseas Fax 61 2 9748 4289 Email info bromic...

Страница 3: ... plug and the permanence of the warning tag shall be determined in accordance with Test for Permanence of Cord Tag Section 53 This Installation Operation and Service manual should not be removed from the site of installation Installer should leave manual with the customer for future reference Any guard or other protective device removed for servicing conducted by an authorised person must be repla...

Страница 4: ... FLOOR 3 0 110 12 13 18 12 6 WARNING DO NOT MOUNT THE HEATER VERTICALLY Heater MUST be installed so that the tube elements are horizontal Failure to do this will cause the heating element within the tube to sag and cause premature burnout Installing vertically will void the manufacturers warranty WARNING DO NOT MOUNT THE HEATER VERTICALLY For outdoor installation heater must be mounted with face o...

Страница 5: ...ed 2 Heater must be installed with heater surface at least 2400mm above the floor level Supplied suspension tubes position heater surface 1000mm below the ceiling surface If required cut down length of suspension tubes to ensure correct installation height Minimum distance from front surface of heater to ceiling surface must be 250mm for 2000W 3000W models 330mm for 4000W 6000W models 3 If suspens...

Страница 6: ... for at least 105 C 3 For supply connection use wires suitable for at least 105 C and at least 1 5mm2 for 2000W and 3000W models 2 5mm2 for 4000W and 6000W models The fixed wiring must be positioned away from protect ed from the enclosure of the heater 4 Make electrical connections in accordance with local electrical code regulations For outdoor installation WARNING ELECTRICAL SHOCK HAZARD Serious...

Страница 7: ...Element 7 Assemble new Tube Element Hex Nut Spring Washer and Ring Terminal must be assembled tightly at both ends of element 8 Element Lock Brackets and Element End Covers must be replaced at both ends of the heater Assemble front cover and secure with 3 screws REPLACEMENT PART LIST No Description BH0420006 2000W BH0420007 3000W BH0420008 4000W BH0420009 6000W 1 Tube Element BH8180001 BH8180002 B...