Directions for use

Automatic  controls  are  safety  devices  and  shall  not  be 
opened. The manufacturer’s responsibility and guarantee 
are invalid if the control is unduly opened. 

A  regulation  shutdown  must  occur  every  24hours  to 
enable the unit to check its own efficiency (systems for 
non permanent operation)

Connect and disconnect the unit only after switching off 
the power supply

Avoid exposing the unit to dripping water

Ventilation  and  the  lowest  temperature  ensures  the 
longest life of the control

Electrical Installation

Live and Neutral should be connected correctly; a mistake 
could cause a dangerous situation.

Before  starting  the  system  check  cables  carefully  for 
incorrect installation

The earth terminal of the control, the metal frame of the 
burner and the earth on the mains supply must be well 
connected

OPERATION DATA - HONEYWELL CONTROL BOX 

CONTINUED...

Operation

At  every  start,  the  control  unit  proceeds  to  a  self-checking 
of  its  own  components.  During  the  pre-purge  or  waiting 
time (TW) the internal circuit makes a test of the flame signal 
amplifier. Extraneous light or fault in the amplifier will result 
in  the  simulation  of  a  flame  which  will  prevent  the  control 
from starting.

At the end of the waiting or pre-purge time, the gas valve is 
energised and the ignition device is operated. In this way, the 
safety time (TS) begins.

If  a  flame  is  detected  during  the  safety  time,  the  ignition 
device is inhibited and the gas valve remains energised.

If  the  control  does  not  detect  any  flame  signal  during  the 
safety time, at the end of safety time (TS), the unit proceeds 
to lockout and the gas valve and ignition device are switched 
off.

If the established flame signal is lost, (during the safety time 
or  during  operation  thereafter)  this  will  cause  the  ignition 
device to be reactivated within 1 second.

If  the  burner  does  not  light  within  25  seconds  of  ignition 
reactivation, the heater will enter failure lockout mode and 
must be reset. 

OPERATION DATA 

HONEYWELL VALVE:

The VK series gas control have been specially developed for 
application in domestic appliances. The Honeywell Gas Valve 
is a multi-functional control which incorporates an adjustable 
direct acting pressure regulator. It is designed for operation 
on 220/240V.

Standard Specifications 

1/2” G Female Pipe Thread connection

Ambient Temperature Range of 0°C to 60°C

Compact Size: 86.5mm x 63.5mm x 65.9mm

50mb Pressure Rating

1/2” x 1/2” (BSP- G) Inlet and Outlet

Earthing terminal – 6mm spade tab

Tamper resistant screws

Top mounted coils that can be field replaced

TECHNICAL DATA

Max inlet working pressure

50 mbar

Installation group 

Group 2

Operating Temperature

0°C to 60°C

Voltage Ratings

220/240VAC
50/60Hz .52A

Adjust Regulator Pressure

Unscrew the regulator cover.

Unscrew the outlet plug to measure the outlet regulator 
pressure by using manometer.

Adjust  the  pressure  by  turning  the  regulator  screw 
clockwise or anti wise.

Adjust the pressure according to appliance specification.

Inlet Pressure

Outlet Pressure

Regulator

IMPORTANT

Remember to place the regulator cover, outlet and inlet back 
on.

!

Содержание platinum Smart-heat

Страница 1: ...mediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For Outdoors Use Only WARNING WARNING Improper installation adjustment alteration service or maintenance can cause property ...

Страница 2: ... MANUAL CAREFULLY before installing or servicing this product UÊ Improper installation operation or maintenance can result in death severe injury or property damage UÊ Installation must be carried out by Authorized person s in accordance with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code CSA B149 1 or Prop...

Страница 3: ...TION 12 LEAKAGE TEST 12 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 13 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 13 OPERATING INSTRUCTIONS 14 TURNING THE APPLIANCE ON 14 TURNING THE APPLIANCE OFF 14 MAINTENANCE AND SERVICING 14 REGULAR SERVICE REQUIREMENTS 14 EXTERIOR SERVICING 14 OPTIMUM MOUNTING DISTANCE 15 HONEYWELL CONTROL 15 HONEYWELL VALVE 16 OPERATION DATA FENWAL CONTROL BOX 17 DUNGS GAS VA...

Страница 4: ...ted by an authorized person UÊ Inspect the hose assembly before each use of the appliance UÊ The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged UÊ The replacement hose assembly must be CSA approved UÊ The hose assembly is not to be located in areas where the hose may be subject to accidenta...

Страница 5: ...D 1 SUTTOR ST SILVERWATER NSW 2128 SYDNEY AUSTRALIA CSA Approval No 2345658 Gas Consumption 23 600 BTU 23 600 BTU 39 800 BTU 39 800 BTU Gas Type Propane Gas LPG Only Natural Gas Propane Gas LPG Only Natural Gas Max Line Pressure 14 W C 14 W C 14 W C 14 W C Min Line Pressure 11 W C 6 W C 11 W C 6 W C Manifold Pressure At Valve Test Point 10 W C 5 W C 10 W C 5 W C Orifice Size 0 85mm 1 3mm 0 85mm 1 ...

Страница 6: ...tion UÊ without stagnant areas UÊ where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one of the following 1 An enclosure with walls on all sides but at least one permanent opening at ground level ref Appendix A Example 1 2 Within a partial enclosure that includes an overhead cover and no m...

Страница 7: ...ve cover the following installation clearances shall apply Minimum height to combustible materials Model A B C 300 Series 3ft 3ft 8ft 500 Series 3ft 3ft 8ft Note When installing with the Platinum Smart Heat Heat Shield Part No 2620165 or 2620166 the following installation clearances Shall Apply Minimum height to combustible materials Model A B C 300 Series 14 3ft 8ft 500 Series 14 3ft 8ft Note Hea...

Страница 8: ...UÊ Slide Gas Connector and Wiring Harness inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm UÊ Ensure that the arm faces downwards at a 55º angle UÊ Position the 4 mounting holes on the arms plate over the corresponding fixtures on the heater Manipulate the gas hose as necessary to allow for correct alignment UÊ Insert and tighten 4 M6 bolts as pr...

Страница 9: ... the arm can slide into place TIP Do not install the mounting pin at this point Step 5 Connect the CSA approved flexible connector to the Gas Valve Outlet Fitting UÊ Position heater and hose so that the gas hose and fitting are in alignment UÊ NOTE ensure that the hose nut and valve fitting are parallel to one another and threads are engaged correctly before tightening Incorrect installation can c...

Страница 10: ...g the instructions below Wiring harness IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only For Honeywell Control UÊ Using a pair of needle nose pliers grip the white ionisation terminal as shown being mindful of the terminal pins of the control module Ignition smaller terminal Ionisation larger terminal UÊ Insert the ionisation terminal into th...

Страница 11: ...ked with the symbol 8 Connect gas inlet fitting to mains gas supply in accordance with local gas installation code and gas supply installation section of manual Leak test with soapy water 9 Fix Front cover to control housing using the 8xM4 screws provided 10 Main Power supply connection is to completed in line with instructions in the Power supply installation section of this manual IMPORTANT Afte...

Страница 12: ...ay be subject to accidental damage POWER SUPPLY INSTALLATION WARNING This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug The Platinum Smart Heat Heater comes standard with 36 of power cord in addition to the Approved 3...

Страница 13: ... 2 Assemble pole to the mounting bracket using the M8x100mm and M19x100mm bolts and fix using nuts and washers as supplied 3 Assemble both lower paddles to the pole back to back 4 Fix Heater to Lower paddles using suitable fixtures NOTE Platinum Heating recommends running power and gas lines to the heater inside the pole to reduce visibility and likelihood of damage INSTALLATION INSTRUCTIONS CONTI...

Страница 14: ...if the hose is damaged The replacement hose assembly must be CSA approved with 3 8 SAE flared ends To Check the Gas Hose remove control housing cover by removing 8 screws and slide cover outwards Alternatively disassemble heater by reversing the installation instructions as outlined in Installation section of this handbook 2 VISUALLY CHECK BURNER FLAMES During heaters function visually check that ...

Страница 15: ...ion and subsequent restoration of the mains power supply Features UÊ Compliance with CSA standard for automatic gas burner flame monitoring and control systems UÊ Compliance with EN 298 European standard for automatic gas burner flame monitoring and control systems UÊ Compliance with AGA Australian standard for automatic gas burner flame monitoring and control systems UÊ Flame monitoring based on ...

Страница 16: ...lve remains energised If the control does not detect any flame signal during the safety time at the end of safety time TS the unit proceeds to lockout and the gas valve and ignition device are switched off If the established flame signal is lost during the safety time or during operation thereafter this will cause the ignition device to be reactivated within 1 second If the burner does not light w...

Страница 17: ...ion UÊ The ground terminal of the control the metal frame of the burner and the ground on the mains supply must be well connected Operation When a call for heat is received from the thermostat supplying 24 volts to TH W the control will reset perform a self check routine flash the diagnostic LED and a pre purge delay begins Following the pre purge period the gas valve is energized and sparks comme...

Страница 18: ...230 V 2 x 5 5 VA Electrical connection Molex System connection coil or Option Connection box with integrated cable Installation position Solenoid at any position between vertical and hori zontal axis OPERATION DATA WHITE RODGERS VALVE The White Rodgers Gas Valve is a compact multi functional control which incorporates an adjustable direct acting pressure regulator It operates on 24V Standard Speci...

Страница 19: ... Ionisation HONEYWELL Red 230 V Blue Purple Purple Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90ºC type UL approved wire or its equivalent IfTransformer must be replaced a UL approved model of similar type must be used SEE INSTRUCTION MANUAL FOR DETAILS ON HOW TO CONNECT THE ELECTRICAL COMPONENTS TRANSFORMER ...

Страница 20: ...PONENTS GND V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER WHITE RODGERS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90ºC type UL approved wire or its equivalent IfTransformer must be replaced a UL approved model of similar type must be used WIRING DIAGRAM FENWAL CONTROL WHITE RODGERS GAS VALVE ...

Страница 21: ...ICAL COMPONENTS GND V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER DUNGS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90ºC type UL approved wire or its equivalent IfTransformer must be replaced a UL approved model of similar type must be used WIRING DIAGRAM FENWAL CONTROL DUNGS GAS VALVE ...

Страница 22: ...24 21 20 19 13 14 10 10 27 7 7 28 5 4 3 1 2 6 18 17 16 26 11 22 12 12 8 9 30 6 15 23 14 34 REPLACEMENT PARTS ...

Страница 23: ...neywell BH8080010 BH8080011 14 Wiring Harness Ignitor Assembly Fenwal 15 Inner Skin BH8080028 BH8080029 16 Wall Bracket Assembly BH8080001 BH8080001 17 Honeywall Control BH8080015 BH8080015 18 Honeywell Gas Valve BH8080014 BH8080014 19 Fenwal Control 20 Dungs 24V Gas Valve 21 WhiteRodger24VGas Valve 22 19mm ID Grommet BH8080033 BH8080033 23 8mm ID Grommet BH8080034 BH8080034 24 Gas Inlet Fitting 1...

Страница 24: ...alled on this site 3 Tile ________ 5 Tile ________ What type of gas is used LPG Natural Gas Is Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s installation location pose a hazard to the site Yes No Do heater clearances match the minimum requirements outlined in the Installation Requirements section of the Installation Operation and Servic...

Страница 25: ...or until at least 6 W C for natural gas or 11 W C for propane precedes heater s control assembly 3 Clean orifice 4 Provide adequate ventilation of by products 5 Replace manifold 6 Increase gas pressure or replace piping 7 Remove with bottle brush Gas odour 1 Loose pipe connection 2 Defective regulator 3 Defective manual shut off valve 4 Defective gas control valve 5 Loose flexible hose 1 Check all...

Страница 26: ...APPENDIX A ...

Страница 27: ...APPENDIX A CONTINUED ...

Отзывы: