REPLACEMENT PARTS DISCRIPTION

Note: For more information on obtaining spare parts contact the place of purchase or

BROMIC HEATING 

Head Office: 1 Suttor Street, Silverwater, Sydney, NSW 2128 Australia    

Telephone: 1300 276 642 (within Australia) or +61 2 9748 3900 (from overseas)  Fax: +61 2 9748 4289   

Email: [email protected]   Web: www.bromicheating.com

No. Description

Part No. 300 Series

Part No. 500 Series

1

Glass Retainer - Top

BH8080002

BH8080003

2

Glass Retainer - Bottom

BH8080004

BH8080005

3

Wind Kicker

BH8080006

BH8080007

4

Glass

BH8080008

BH8080009

5

Reflector Assembly

BH8080018

BH8080019

6

Glass Retainer Side

BH8080020

BH8080020

7

Side Shield

BH8080021

BH8080021

8

Sail

BH8080022

BH8080023

9

Rear Housing

BH8080024

BH8080025

10

Rear Housing Mount (Lower)

11

Rear Cover Assembly

BH8080026

BH8080027

12

Rear Cover Mount

13

Burner

BH8080030

BH8080030

14

Wiring H Ignitor Assembly- Honeywell

BH8080010

BH8080011

14

Wiring H Ignitor Assembly- Fenwal

15

Inner Skin

BH8080028

BH8080029

16

Wall Bracket Assembly

BH8080001

BH8080001

17

Honeywall Control

BH8080015

BH8080015

18

Honeywell Gas Valve

BH8080014

BH8080014

19

Fenwal Control

20

Dungs 24V Gas Valve

21

WhiteRodger24VGas Valve

22

19mm ID Grommet

BH8080033

BH8080033

23

8mm ID Grommet

BH8080034

BH8080034

24

Gas Inlet Fitting (1/2” Gas Valve)

BH8080035

BH8080035

25

Gas Inlet Fitting (WhiteRodgers Gas Valve)

26

Gas Outlet Fittings (1/2”Gas Valve)

BH8080036

BH8080036

27

Gas Outlet Fitting (WhiteRodgers Gas Valve)

28

Manifold Assembly - Natural Gas

BH8080037

BH8080037

28

Manifold Assembly - LPG

BH8080093

BH8080090

29

Manifold Inlet Fitting

30

Injector (LPG)

BH8080016

BH8080016

30

Injector (NG)

BH8080017

BH8080017

31

Wall Bracket Replacement Screw Set including Gas Hose

BH8080051

BH8080051

32

Heater Replacement Screw Set

33

Deflector Screw Set including arm

BH8080052

BH8080052

34

Transformer – 110V-230V (Honeywall)

BH8080050

BH8080050

34

Transformer – 110V-24V (Fenwal)

Содержание platinum Smart-heat

Страница 1: ...mediately call your gas supplier or fire department Do not store or use gasoline or other flamable vapor and liquids in the vicinity of this or any other appliance An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING For Outdoors Use Only WARNING WARNING Improper installation adjustment alteration service or maintenance can cause property ...

Страница 2: ... MANUAL CAREFULLY before installing or servicing this product UÊ Improper installation operation or maintenance can result in death severe injury or property damage UÊ Installation must be carried out by Authorized person s in accordance with local codes or in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 Natural Gas and Propane Installation Code CSA B149 1 or Prop...

Страница 3: ...TION 12 LEAKAGE TEST 12 HEAT DEFLECTOR INSTALLATION INSTRUCTIONS 13 CEILING MOUNT POLE INSTALLATION INSTRUCTIONS 13 OPERATING INSTRUCTIONS 14 TURNING THE APPLIANCE ON 14 TURNING THE APPLIANCE OFF 14 MAINTENANCE AND SERVICING 14 REGULAR SERVICE REQUIREMENTS 14 EXTERIOR SERVICING 14 OPTIMUM MOUNTING DISTANCE 15 HONEYWELL CONTROL 15 HONEYWELL VALVE 16 OPERATION DATA FENWAL CONTROL BOX 17 DUNGS GAS VA...

Страница 4: ...ted by an authorized person UÊ Inspect the hose assembly before each use of the appliance UÊ The hose assembly must be replaced prior to the appliance being put into operation if there is evidence of excessive abrasion or wear or if the hose is damaged UÊ The replacement hose assembly must be CSA approved UÊ The hose assembly is not to be located in areas where the hose may be subject to accidenta...

Страница 5: ...D 1 SUTTOR ST SILVERWATER NSW 2128 SYDNEY AUSTRALIA CSA Approval No 2345658 Gas Consumption 23 600 BTU 23 600 BTU 39 800 BTU 39 800 BTU Gas Type Propane Gas LPG Only Natural Gas Propane Gas LPG Only Natural Gas Max Line Pressure 14 W C 14 W C 14 W C 14 W C Min Line Pressure 11 W C 6 W C 11 W C 6 W C Manifold Pressure At Valve Test Point 10 W C 5 W C 10 W C 5 W C Orifice Size 0 85mm 1 3mm 0 85mm 1 ...

Страница 6: ...tion UÊ without stagnant areas UÊ where gas leakage and products of combustion are rapidly dispersed by wind and natural convection Any enclosure in which the appliance is used shall comply with one of the following 1 An enclosure with walls on all sides but at least one permanent opening at ground level ref Appendix A Example 1 2 Within a partial enclosure that includes an overhead cover and no m...

Страница 7: ...ve cover the following installation clearances shall apply Minimum height to combustible materials Model A B C 300 Series 3ft 3ft 8ft 500 Series 3ft 3ft 8ft Note When installing with the Platinum Smart Heat Heat Shield Part No 2620165 or 2620166 the following installation clearances Shall Apply Minimum height to combustible materials Model A B C 300 Series 14 3ft 8ft 500 Series 14 3ft 8ft Note Hea...

Страница 8: ...UÊ Slide Gas Connector and Wiring Harness inside the centre of the arm and have them exit through the shaped cut out on top surface of the arm UÊ Ensure that the arm faces downwards at a 55º angle UÊ Position the 4 mounting holes on the arms plate over the corresponding fixtures on the heater Manipulate the gas hose as necessary to allow for correct alignment UÊ Insert and tighten 4 M6 bolts as pr...

Страница 9: ... the arm can slide into place TIP Do not install the mounting pin at this point Step 5 Connect the CSA approved flexible connector to the Gas Valve Outlet Fitting UÊ Position heater and hose so that the gas hose and fitting are in alignment UÊ NOTE ensure that the hose nut and valve fitting are parallel to one another and threads are engaged correctly before tightening Incorrect installation can c...

Страница 10: ...g the instructions below Wiring harness IMPORTANT Electrical connections must be completed by trained and authorized electrical technicians only For Honeywell Control UÊ Using a pair of needle nose pliers grip the white ionisation terminal as shown being mindful of the terminal pins of the control module Ignition smaller terminal Ionisation larger terminal UÊ Insert the ionisation terminal into th...

Страница 11: ...ked with the symbol 8 Connect gas inlet fitting to mains gas supply in accordance with local gas installation code and gas supply installation section of manual Leak test with soapy water 9 Fix Front cover to control housing using the 8xM4 screws provided 10 Main Power supply connection is to completed in line with instructions in the Power supply installation section of this manual IMPORTANT Afte...

Страница 12: ...ay be subject to accidental damage POWER SUPPLY INSTALLATION WARNING This heater is equipped with a three prong grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from this plug The Platinum Smart Heat Heater comes standard with 36 of power cord in addition to the Approved 3...

Страница 13: ... 2 Assemble pole to the mounting bracket using the M8x100mm and M19x100mm bolts and fix using nuts and washers as supplied 3 Assemble both lower paddles to the pole back to back 4 Fix Heater to Lower paddles using suitable fixtures NOTE Platinum Heating recommends running power and gas lines to the heater inside the pole to reduce visibility and likelihood of damage INSTALLATION INSTRUCTIONS CONTI...

Страница 14: ...if the hose is damaged The replacement hose assembly must be CSA approved with 3 8 SAE flared ends To Check the Gas Hose remove control housing cover by removing 8 screws and slide cover outwards Alternatively disassemble heater by reversing the installation instructions as outlined in Installation section of this handbook 2 VISUALLY CHECK BURNER FLAMES During heaters function visually check that ...

Страница 15: ...ion and subsequent restoration of the mains power supply Features UÊ Compliance with CSA standard for automatic gas burner flame monitoring and control systems UÊ Compliance with EN 298 European standard for automatic gas burner flame monitoring and control systems UÊ Compliance with AGA Australian standard for automatic gas burner flame monitoring and control systems UÊ Flame monitoring based on ...

Страница 16: ...lve remains energised If the control does not detect any flame signal during the safety time at the end of safety time TS the unit proceeds to lockout and the gas valve and ignition device are switched off If the established flame signal is lost during the safety time or during operation thereafter this will cause the ignition device to be reactivated within 1 second If the burner does not light w...

Страница 17: ...ion UÊ The ground terminal of the control the metal frame of the burner and the ground on the mains supply must be well connected Operation When a call for heat is received from the thermostat supplying 24 volts to TH W the control will reset perform a self check routine flash the diagnostic LED and a pre purge delay begins Following the pre purge period the gas valve is energized and sparks comme...

Страница 18: ...230 V 2 x 5 5 VA Electrical connection Molex System connection coil or Option Connection box with integrated cable Installation position Solenoid at any position between vertical and hori zontal axis OPERATION DATA WHITE RODGERS VALVE The White Rodgers Gas Valve is a compact multi functional control which incorporates an adjustable direct acting pressure regulator It operates on 24V Standard Speci...

Страница 19: ... Ionisation HONEYWELL Red 230 V Blue Purple Purple Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90ºC type UL approved wire or its equivalent IfTransformer must be replaced a UL approved model of similar type must be used SEE INSTRUCTION MANUAL FOR DETAILS ON HOW TO CONNECT THE ELECTRICAL COMPONENTS TRANSFORMER ...

Страница 20: ...PONENTS GND V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER WHITE RODGERS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90ºC type UL approved wire or its equivalent IfTransformer must be replaced a UL approved model of similar type must be used WIRING DIAGRAM FENWAL CONTROL WHITE RODGERS GAS VALVE ...

Страница 21: ...ICAL COMPONENTS GND V 2 White S 1 T H V 1 Red Orange Yellow Green TRANSFORMER DUNGS Note If any of the original wire as supplied with the heater must be replaced it must be replaced with 18AWG 90ºC type UL approved wire or its equivalent IfTransformer must be replaced a UL approved model of similar type must be used WIRING DIAGRAM FENWAL CONTROL DUNGS GAS VALVE ...

Страница 22: ...24 21 20 19 13 14 10 10 27 7 7 28 5 4 3 1 2 6 18 17 16 26 11 22 12 12 8 9 30 6 15 23 14 34 REPLACEMENT PARTS ...

Страница 23: ...neywell BH8080010 BH8080011 14 Wiring Harness Ignitor Assembly Fenwal 15 Inner Skin BH8080028 BH8080029 16 Wall Bracket Assembly BH8080001 BH8080001 17 Honeywall Control BH8080015 BH8080015 18 Honeywell Gas Valve BH8080014 BH8080014 19 Fenwal Control 20 Dungs 24V Gas Valve 21 WhiteRodger24VGas Valve 22 19mm ID Grommet BH8080033 BH8080033 23 8mm ID Grommet BH8080034 BH8080034 24 Gas Inlet Fitting 1...

Страница 24: ...alled on this site 3 Tile ________ 5 Tile ________ What type of gas is used LPG Natural Gas Is Are the heater s exposed to salt air or any other corrosive or chemical atmosphere Yes No Does the heater s installation location pose a hazard to the site Yes No Do heater clearances match the minimum requirements outlined in the Installation Requirements section of the Installation Operation and Servic...

Страница 25: ...or until at least 6 W C for natural gas or 11 W C for propane precedes heater s control assembly 3 Clean orifice 4 Provide adequate ventilation of by products 5 Replace manifold 6 Increase gas pressure or replace piping 7 Remove with bottle brush Gas odour 1 Loose pipe connection 2 Defective regulator 3 Defective manual shut off valve 4 Defective gas control valve 5 Loose flexible hose 1 Check all...

Страница 26: ...APPENDIX A ...

Страница 27: ...APPENDIX A CONTINUED ...

Отзывы: