6.  PRODUCT LOADING AND STORAGE

Start-up

•  Clean the interior surface with a soft cloth and warm water before loading.
•  Position top and bottom shelves at marked locations to maintain correct air flow in unit.
•  Recommend placement of product on centre of shelves or evenly distributed on shelfs with 

minimum 30mm air gap between containers or use of perforated baskets.

•  Never stack containers and do not load unit excessively whereby air flow across the cabinet is 

restricted.

•  Do not load product above the top shelf load line marked on the side of the cabinet.
•  Do not block the evaporator fan.
•  Use cold mass (i.e. 300ml saline water bottles) on unused shelves and ensure containers are 

separated by 30mm on all sides. This is essential for maintaining correct storage temperature 

during door openings.

•  Avoid partial shelf loading, use cold mass on unused space
•  Use cold mass (i.e. water bottle) on unused shelves.
•  Keep refrigerator door openings to a minimum. Limit door opening durations to less than 

30seconds. Wait 10 minutes for product and cabinet temperature to stabilise before opening 

door again.

•  Ensure products and materials are between 2 and 8°C before loading – if there is a breach in the 

cold-chain, isolate the affected products. Do not use or discard until advice is given.

•  Some products are sensitive to ultraviolet (UV) light, please see storage guidelines from the 

manufacturer before removing from packaging.

•  Do not store food and other goods in the refrigerator.
•  Do not change controller settings. This is essential for maintaining correct storage temperature.
•  Maximum recommended shelf load is 20kg. 

NOTE: Bromic cannot be responsible for loss of stock or damage to stock. 

Please refer to the ‘National Vaccine Storage Guidelines: Strive for 5’ for more information on 

vaccine storage and handling or contact your local state or territory health department.

(https://www.health.gov.au/resources/publications/national-vaccine-storage-guidelines-strive-for-5) 

WARNING

: Failure to follow the guidelines below will result in cabinet 

temperatures below 2°C and above 8°C

IMPORTANT

: Run the refrigerator for at least 2 hours before loading.

Содержание Medifridge MED0220GD

Страница 1: ...22 03 2022 V2 MED0220GD MEDO374GD ...

Страница 2: ...hout prior notification This Installation operation and service manual may not be reproduced in any form with prior written consent from Bromic Refrigeration 1 PREFIX 3 2 IMPORTANT NOTES WARNINGS 4 3 PRODUCT OVERVIEW 5 4 INSTALLATION 6 5 OPERATION 8 6 PRODUCT LOADING AND STORAGE 10 7 MAINTENANCE 11 8 TROUBLESHOOTING 12 9 ENVIRONMENTAL DISPOSAL NOTES 13 10 WARRANTY 14 ...

Страница 3: ...er strict control Refer to the National Vaccine Storage Guidelines Strive for 5 for more information on vaccine storage and handling or contact your local state of territory health department https www health gov au resources publications national vaccine storage guide lines strive for 5 MIXING OF VACCINE PRODUCTS WITH OTHER PRODUCT TYPES IS NOT RECOMMENDED The loading procedure of fridges contain...

Страница 4: ...ack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible of their safety Keep packaging material out reach of children Children should be carefully supervised to ensure that they do not play with the appliance Do not attempt to alter the appliance in any manner Please pay attention to the maximum load limit when ...

Страница 5: ...Powder coated sheet metal Electrical Voltage V 240 240 Frequency Hz 50 50 Input Power W 235 350 Current A 2 2 7 Door Solid or Glass Low E Glass Argon Gas Low E Glass Argon Gas Shape Flat Flat Self Closing Yes Yes Door Lock Yes Yes Door Switch Yes Yes Shelves Qty 4 6 Type Open rung shelf Open rung shelf Depth mm 400 400 Adjustable Yes Yes Capacity kg 20 20 Internal LIghting Internal Light Yes Yes A...

Страница 6: ...stall the appliance where it is exposed to warm draughts or open doors Keep the air intake and outlets free of obstructions Adequate allowance should be made for door openings Ventilation Ensure the following instructions are observed as this is vital for proper and trouble free operation Allow 150mm clearance between walls and the appliance Ensure that the condenser fan is free to take in ambient...

Страница 7: ...able is rated 70 C It is recommended that the cable should not come into contact with parts over 50 C Do not turn off power before consulting the person responsible Mark the power source clearly so the refrigerator is not unplugged or turned off accidentally Before Operating If the appliance has been sharply tilted or transported in the horizontal position it must be left to stand in the upright p...

Страница 8: ...gged in The electronic controller will display the current cabinet temperature after the unit has been connected to the power supply The LED indicates that refrigeration circuit is operating During the start up delay 3 minutes the LED is flashing Setting the temperature NOTE The controller is factory set at 4 C The controller is programmed to control cabinet temperatures between 2 to 8 C Controlle...

Страница 9: ...d the maximum and minimum temperatures two 2 times a day Recordings should be taken before the first door opening of the day MIN Temperature i Press the arrow key ii The Lo message will be displayed followed by the minimum temperature recorded iii Press the arrow key again or wait 5 seconds the normal display will be displayed MAX Temperature i Press the arrow key ii The Hi message will be display...

Страница 10: ... minimum Limit door opening durations to less than 30seconds Wait 10 minutes for product and cabinet temperature to stabilise before opening door again Ensure products and materials are between 2 and 8 C before loading if there is a breach in the cold chain isolate the affected products Do not use or discard until advice is given Some products are sensitive to ultraviolet UV light please see stora...

Страница 11: ...ve the products and transfer to a suitable location prior to cleaning the inside of the cabinet Do not use any aggressive or abrasive cleaning agents Never use a water hose or a high pressure jet to clean Do not use sharp or pointed objects for cleaning Clean the inside and outside of the appliance with a clean damp cloth or with a neutral cleanser Dry all surfaces with a dry cloth WARNING Disconn...

Страница 12: ...ate ventilation C Wall clearances below minimum distance D Dirty condenser coil E Ice build up on evaporator coil A Relocate unit B Keep ventilation slots free C Adjust to minimum clearance D Clean E Perform extended defrosting Cabinet Temperature Too Low A Set temperature too low A Adjust set temperature Cabinet lights not working A Light not switched on B Light is faulty A Switch on B Replace li...

Страница 13: ...ons must be observed In the interest of preventing environmental nuisance and promoting re use of the high quality materials employed used commercial refrigeration equipment must be collected for expert disposal and recycling Therefore observe the following disposal regulations The cabinet must not be discarded with regular waste The refrigeration circuit must not be damaged Before disposal make i...

Страница 14: ...e of any stock Failure to follow instructions may result in loss of or damage to stock Please refer to the National Vaccine Storage Guidelines Strive for 5 for more information on vaccine storage and handling or contact your local state or territory health department https www health gov au resources publications national vaccine storage guidelines strive for 5 BROMIC CANNOT BE RESPONSIBLE FOR THE...

Страница 15: ...NOTES ...

Страница 16: ...10 Phiney Place Ingleburn NSW 2565 Australia T AU 1300 276 642 F 61 1300 735 115 E refrigeration bromic com au SYDNEY HEAD OFFICE SHOWROOM BROMICGROUP COM NSW VIC QLD TAS WA SA NT ACT ...