S T E P T W O -
C O N N E C T I N G T H E W AT E R S U P P LY:
1. Install a shut off/isolation valve (1 per unit is ideal)
2. Screw the braided hose from the mixer to the shut off valve
The solenoid valve is installed into the water connection to the outlet spout. This must be
accessible for servicing. An access panel in the wall under the outlet is a widely used option.
Observe the flow direction through the valve and ensure that no Teflon tape, copper filings,
grit or other foreign particals enter and foul the valve. An inline strainer (60 mesh) must be fitted
before the valve.
The water supply is provided via normal plumbing practices, either cold or pre-mixed warm, using
a thermostatic mixing valve, plumbed to the solenoid, then to the outlet.
O U T L E T A N D S E N S O R I N S TA L L AT I O N G U I D E F O R A L L
M O D E L S ( C O N T I N U E D )
S T E P T H R E E -
C O N N E C T I N G T H E P O W E R S O U R C E :
1. Connect the cable coming from the electronic sensor unit or the solenoid valve connector.
2. Connect the other cable coming from the electronic sensor unit to the power source
connector (battery box or transformer).
3. Connect the power source:
a) For battery versions: Install the battery box at the wall underneath the sink using the two
sided adhesive foam tape. The cable connection must point down. (You can use
an optional extension cable in order to assemble the battery box up to 3m away from the
solenoid.)
b) For transformer versions: Check to ensure the power point is switched off. Plug the
transformer into the electricity wall socket and connect the connectors. Once secure,
then turn the power point to the on position.Note that the power pack and connections
are NOT spray or water proof. If water may come into contact with the power pack, the
plug and socket or quick connects, the unit and all of the interconnections should be
installed into a water-proof enclosure.
c) Wait a few seconds before activating the tap. For Wave Sensors, wave the back of your
hand through the beam to turn the water on, and again to turn the water off.
d) If the automatically adjusted sensor range is not satisfactory to your purposes, please
refer to the section entitled “Settings Adjustment”.