background image

•  Note: To operate the advanced functions with the remote control you must have a  

 

compatible product model. The remote control is sold separately.

A D J U S T I N G   T H E   S E T T I N G S   W I T H   T H E   R E M O T E   C O N T R O L

•  Connect the cable coming from the electronic sensor unit or the solenoid valve connector.
•  If necessary, the sensor settings can be adjusted as following: 
•  Shut off the water supply. In order to adjust the sensor with the remote control, hold the  

 

remote control straight in front of the sensor in a distance of about 15-20cm.

•  Choose the function you want to adjust by pressing once on one of the function buttons.  

 

After pressing once on a specific function button, a quick flashing of the red light at the  

 

front of the sensor will occur. At this stage, you can change the setting by pressing the (+)  

 

or the (-) buttons, every press will increase or decrease one unit.

•  After finishing the adjustment, turn the water supply back on.

S E T T I N G S   A D J U S T M E N T

D E T E C T I O N   R A N G E

Only if necessary, use the remote control to adjust the sensor range as follows: 

Press the ‘Range’ button. Wait until a quick flashing of the red light of the sensor 

eye is visible. Then, press + to increase the range and – to reduce it.
Note: Once you have changed the detection range with the remote control, this 

distance is retained by the sensor, even if the power source is disconnected.  

To get back to the self adjustment mode, use the ‘Adj’ button.

E N T R A N C E   T O   T H E   S E L F   A D J U S T M E N T   M O D E

Check that no objects are in front of the sensor. Press the ‘Adj’ button. Once a quick 

flashing of the red light of the sensor eye is visible, remove the remote control and 

move away from the sensor area. The ideal sensor range for the specific location 

will be set automatically. Once the self adjustment has taken place the solenoid 

valve will open for about 1 second as an indication that the ideal sensor range was 

set and the product is ready for use.

S E C U R I T Y   T I M E

The Security time, prevents continuous running of water due to reflections or 

vandalism. By default, if the sensor is covered for more than 90 seconds the water 

flow will shut automatically. 
To resume regular operation any obstruction must be removed.
Press the ‘Sec’ button. Wait until a quick flashing of the red light of the sensor eye is 

visible. Then, press + to increase the security time and – to reduce it. 

D E L AY   O U T   T I M E

This allows the adjustment of the flow time after the users hands have been 

removed from the sensors range. A shorter delay out time will save more water.  

A longer delay out time will assist in ease of use.
If required, the delay out time can be modified as follow;: press the ‘Out’ button. 

Wait until a quick flashing of the red light of the sensor eye is perceived. Then, 

press + to increase the delay out time and – to reduce it.

17

18

Содержание 2.2702.90

Страница 1: ...705 0 0 2 2705 02 2 2705 20 2 2705 22 2 2705 30 2 2705 70 2 2706 0 0 2 2706 02 2 2706 20 2 2706 22 2 2706 30 2 2706 70 2 2706 94 2 2702 90 2 2702 92 ELEC TRO N I C S EN SO R TAP I N STALL ATI O N MAI...

Страница 2: ...ation of your sensor wall set After reading this manual if you still have any questions about the installation process or correct maintainance of the sensor wall set please call us on 61 1300 800 300...

Страница 3: ...for gravity feed systems CO RREC T SOAP VI SCOS IT Y Ensure that the correct soap is selected for the Brosmart Sensor Soap Dispensers A soap with no grit and a viscosity of 100 3800cPs is to be used F...

Страница 4: ...hrough from the rear of the Sensor Mounting tube to the front face Connect the sensor to the leads 1x male connection and 1x female connection Push the sensor into the mounting tube Secure the sensor...

Страница 5: ...op 3 Screw the braided hose into the bottom of the mixer 4 Fit the mixer with the trim to the bench top 5 Refit the mounting plate and fixing but to the underside of the mixer Do the nut up finger tig...

Страница 6: ...e cover plate to seal the unit to the wall Press the plate into position on the wall Apply thread sealant or thread tape to male thread and screw the outlet to the male thread 7 Turn on the water and...

Страница 7: ...ed length Apply thread sealant or thread tape to the male thread of the spout nipple and screw the spout nipple into the female fitting in the wall 7 Run a thin bead of silicone sealant on the inside...

Страница 8: ...able coming from the electronic sensor unit to the power source connector battery box or transformer 3 Connect the power source a For battery versions Install the battery box at the wall underneath th...

Страница 9: ...to the two holes using two screws Important The mounting base should be installed so that the outside surface of the finished wall falls between the min and max lines marked on the base 6 Connect the...

Страница 10: ...ed by the sensor even if the power source is disconnected To get back to the self adjustment mode use the Adj button E NTR A N C E TO TH E S E LF A DJ USTM E NT M O D E Check that no objects are in fr...

Страница 11: ...battery Replace with 6 new batteries Sensor does not flash when user s hands are within the sensor s range Range is too short Increase the range using the remote control Range is too long Decrease the...

Страница 12: ...ceeding recommended limits Improper manipulation tampering bad or lapsed maintenance Foreign bodies dirt or scale introduced by the water supply 2 2702 TF 0 0 0 B ROSMART TR ANSFO RM ER 2 270 5 S F 0...

Страница 13: ...I CSEN 210509...