• Note: To operate the advanced functions with the remote control you must have a
compatible product model. The remote control is sold separately.
A D J U S T I N G T H E S E T T I N G S W I T H T H E R E M O T E C O N T R O L
• Connect the cable coming from the electronic sensor unit or the solenoid valve connector.
• If necessary, the sensor settings can be adjusted as following:
• Shut off the water supply. In order to adjust the sensor with the remote control, hold the
remote control straight in front of the sensor in a distance of about 15-20cm.
• Choose the function you want to adjust by pressing once on one of the function buttons.
After pressing once on a specific function button, a quick flashing of the red light at the
front of the sensor will occur. At this stage, you can change the setting by pressing the (+)
or the (-) buttons, every press will increase or decrease one unit.
• After finishing the adjustment, turn the water supply back on.
S E T T I N G S A D J U S T M E N T
D E T E C T I O N R A N G E
Only if necessary, use the remote control to adjust the sensor range as follows:
Press the ‘Range’ button. Wait until a quick flashing of the red light of the sensor
eye is visible. Then, press + to increase the range and – to reduce it.
Note: Once you have changed the detection range with the remote control, this
distance is retained by the sensor, even if the power source is disconnected.
To get back to the self adjustment mode, use the ‘Adj’ button.
E N T R A N C E T O T H E S E L F A D J U S T M E N T M O D E
Check that no objects are in front of the sensor. Press the ‘Adj’ button. Once a quick
flashing of the red light of the sensor eye is visible, remove the remote control and
move away from the sensor area. The ideal sensor range for the specific location
will be set automatically. Once the self adjustment has taken place the solenoid
valve will open for about 1 second as an indication that the ideal sensor range was
set and the product is ready for use.
S E C U R I T Y T I M E
The Security time, prevents continuous running of water due to reflections or
vandalism. By default, if the sensor is covered for more than 90 seconds the water
flow will shut automatically.
To resume regular operation any obstruction must be removed.
Press the ‘Sec’ button. Wait until a quick flashing of the red light of the sensor eye is
visible. Then, press + to increase the security time and – to reduce it.
D E L AY O U T T I M E
This allows the adjustment of the flow time after the users hands have been
removed from the sensors range. A shorter delay out time will save more water.
A longer delay out time will assist in ease of use.
If required, the delay out time can be modified as follow;: press the ‘Out’ button.
Wait until a quick flashing of the red light of the sensor eye is perceived. Then,
press + to increase the delay out time and – to reduce it.
17
18
Содержание 2.2702.90
Страница 13: ...I CSEN 210509...