Cooling
The cooling fans cool the CPU, main memory, and voltage regulators. The fans use a pull configuration
to move the air from the front of the device to the back of the device.
• Total cooling capacity: 350 watts
• Total air flow: 267 LFM
• Fan operating noise:
‐
Based on ISO 7779
‐
< 60 dB-A
Safety agency approvals
• CAN/CSA-22.2 No.60950-1-07/UL 60950-1-Second Edition
• EN 60825-1 Safety of Laser Products - Part 1: Equipment Classification, Requirements and User’s
Guide
• EN 60825-2 Safety of Laser Products - Part 2: Safety of Optical Fibre Communications Systems
• CE EN60950-1: 2006
• TUV EN60950-1: 2006
• IEC EN60950-1:2005
Electromagnetic approvals
• FCC Part 15, Subpart B (Class A)
• EN 55022 (CE mark) (Class A)
• CISPR-22 (class A)
• ICES-003 (Canada) (Class A)
• AS/NZ 55022 (Australia) (Class A)
• VCCI (Japan) (Class A)
• EN 61000-3-2
• EN 61000-3-3
• EN 61000-6-3
Port specifications
This section provides pin assignments for the following ports:
• Device’s console port (serial connector)
• Device’s management port (RJ-45 unshielded twisted pair (UTP) connector)
Cooling
Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide
75
53-1003823-01