background image

53-1003823-01
18 August 2015

Brocade NetIron CES 2000
Series and NetIron CER
2000 Series

Hardware Installation Guide

Supported Release: Multi-Service IronWare R05.9.00

Содержание NetIron CES 2000 Series

Страница 1: ...53 1003823 01 18 August 2015 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide Supported Release Multi Service IronWare R05 9 00...

Страница 2: ...r its use This informational document describes features that may not be currently available Contact a Brocade sales office for information on feature and product availability Export of technical data...

Страница 3: ...4X 23 Brocade NetIron CES Series 2024C 23 Brocade NetIron CES Series 2024F 23 Brocade NetIron CES Series 2048C 24 Brocade NetIron CES Series 2048CX 24 Brocade NetIron CES Series 2048F 25 Brocade NetIr...

Страница 4: ...7 Powering on the system 58 Operation verification 58 Verifying proper operation 59 Observing the power status LEDs 59 PC or terminal attachment 61 Attaching a PC or terminal 61 Device Management Appl...

Страница 5: ...ment 93 Removing a Copper or fiber optic module 93 Installing a new Copper or fiber optic module 94 Cabling a fiber optic module 94 Tunable 10 GbE DWDM SFP 95 Fiber optic connector cleaning 95 Regulat...

Страница 6: ...6 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003823 01...

Страница 7: ...s the names of user manipulated GUI elements Identifies text to enter at the GUI italic text Identifies emphasis Identifies variables Identifies document titles Courier font Identifies CLI output Iden...

Страница 8: ...ons and warnings Notes cautions and warning statements may be used in this document They are listed in the order of increasing severity of potential hazards NOTE A Note provides a tip guidance or advi...

Страница 9: ...he Technical Assistance Center go to http www brocade com services support index html If you have purchased Brocade product support directly from Brocade use one of the following methods to contact th...

Страница 10: ...we have made every effort to ensure the accuracy and completeness of this document However if you find an error or an omission or you think that a topic needs further development we want to hear from...

Страница 11: ...upported hardware and software The following hardware platforms are supported by this release of this guide Supported devices TABLE 1 NetIron CES 2000 and NetIron CER 2000 Series Supported Notes Broca...

Страница 12: ...istent command line interface CLI documentation for all products Brocade is in the process of completing a standalone command reference for the NetIron platforms This process involves separating comma...

Страница 13: ...lti Service IronWare Security Configuration Guide Multi Service IronWare Switching Configuration Guide Multi Service IronWare Routing Configuration Guide Multi Service IronWare Traffic Management Conf...

Страница 14: ...Related publications 14 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003823 01...

Страница 15: ...ions ranging from metro edge networks ISPs data centers large enterprises government networks and education or research can be addressed with the Brocade NetIron CES Series 2000 Series and Brocade Net...

Страница 16: ...0 Hybrid Fiber HF model with 2x10G XFP uplink ports FIGURE 1 Brocade NetIron CES Series 2024C 4X FIGURE 2 Brocade NetIron CES Series 2024F 4X FIGURE 3 Brocade NetIron CES Series 2024C FIGURE 4 Brocade...

Страница 17: ...rocade NetIron CES Series 2048CX FIGURE 8 Brocade NetIron CES Series 2048FX There are also fourteen models in the NetIron Carrier Ethernet Router CER and CER RT 2000 Series Product Overview Brocade Ne...

Страница 18: ...neously store up to 1 5 million IPv4 routes and up to 256 000 IPv6 routes Brocade NetIron CER Series 2048C accommodates 48 port 10 100 1000 Copper RJ45 model with 4 combination 100 1000 Hybrid Fiber H...

Страница 19: ...CER Series 2024C FIGURE 12 Brocade NetIron CER Series 2024F FIGURE 13 Brocade NetIron CER Series 2048C Product Overview Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installati...

Страница 20: ...etIron CES Series 2000 Series switch offers network planners a broad set of high performance IPv4 Classic Layer 2 Provider Bridge PB and Provider Backbone Bridge PBB functionalities in the same device...

Страница 21: ...ull Layer 2 Switching and full Layer 3 RIP OSPF ISIS and BGP It also includes virtual routing in non MPLS environments via Multi VRF The Advanced Services Premium ADV_SVCS_PREM package includes MPLS L...

Страница 22: ...supply specifications and pinouts refer to the Hardware Specifications on page 71 The following figures show the front panels of the various NetIron 2024 and 2048 devices NOTE This is only a represen...

Страница 23: ...slot for an optional field upgradable 2 port 10 GbE XFP module one DB9 serial management interface port labeled Console one 10 100 1000 MbE RJ45 out of band management port one resilient six unit fan...

Страница 24: ...band management port one resilient six unit fan tray and two AC power supply bays for 1 1 redundancy with one 500W AC power supply included FIGURE 23 Brocade NetIron CES Series 2048C device 1 Four com...

Страница 25: ...FIGURE 25 Brocade NetIron CES Series 2048F device 1 Forty eight 100 1000 MbE SFP ports Brocade NetIron CES Series 2048FX Brocade NetIron CES Series 2048FX Fiber switch has forty eight 100 1000 MbE SFP...

Страница 26: ...2024C device with the optional 2 ports of 10 G XFP uplink 1 Optional 10 GbE XFP ports 2 Four combination 100 1000 MbE SFP ports 3 Twenty four 10 100 1000 MbE RJ45 ports Brocade NetIron CER Series 2024...

Страница 27: ...one 10 100 1000 MbE RJ45 out of band management port one resilient six unit fan tray and two AC power supply bays for 1 1 redundancy with one 500W AC power supply included FIGURE 29 Brocade NetIron C...

Страница 28: ...MbE RJ45 out of band management port one resilient six unit fan tray and two AC power supply bays for 1 1 redundancy with one 500W AC power supply included FIGURE 31 Brocade NetIron CER Series 2048F...

Страница 29: ...ansceivers Each device that has four 10 Gigabit Ethernet uplink ports supports 10 Gigabit Small Form Factor Pluggable SFP MSA compliant optical transceivers Serial Management Interface console port Th...

Страница 30: ...and received on the fiber port Bottom Right hand port On The port is connected Off No fiber port connection exists Blinking Traffic is being transmitted and received on the fiber port 10 Gbps Port LED...

Страница 31: ...T and the Brocade NetIron CER Series 2048F 4X RT come with four 10 Gigabit Ethernet ports installed The four 10 Gigabit Ethernet uplink ports support 10 Gigabit Small Form Factor Pluggable SFP MSA com...

Страница 32: ...tor E1MG CWDM80 1550 CWDM SFP optic 80Km 1550nm LC connector E1MG CWDM80 1570 CWDM SFP optic 80Km 1570nm LC connector E1MG CWDM80 1590 CWDM SFP optic 80Km 1590nm LC connector E1MG CWDM80 1610 CWDM SFP...

Страница 33: ...features a port s region does not affect configuration or operation of the feature If a port s region does affect configuration or operation of a feature it is noted and described in the appropriate...

Страница 34: ...endor Version Unknown Part Unknown Serial Unknown Port 2 1 Type 10GBASE SR SW XFP Vendor FOUNDRY NETWORKS Version 00 Part FTLX8511D3 F1 Serial KCP02X8 Port 2 2 Type 10GBASE SR SW XFP Vendor FOUNDRY NE...

Страница 35: ...ies and power supply failure on page 36 AC power supplies AC power supplies shows a rear view of a device containing one AC power supply FIGURE 33 AC Power Supply 1 Power supply 2 Six cooling fans DC...

Страница 36: ...CE 2000 FAN pre installed or as a spare All other models support the NI CE 2000 FAN The fans in the devices include six four speed fans that operate at low speed medium speed medium high speed and hi...

Страница 37: ...u configure the system s IP address and configure routing features To access the CONFIG mode you must already be logged into the Privileged level of the EXEC mode NOTE You can assign passwords using t...

Страница 38: ...s can be up to 48 characters long IP address configuration The devices implement separate data and control planes This architecture affects how you assign IP addresses Table 7 outlines the interfaces...

Страница 39: ...nt module becomes the active module the IP address is assigned to the new active management module port For example to assign the IP address 10 0 1 1 to the management interface do the following 1 At...

Страница 40: ...erases the factory test configuration if still present device erase startup config CAUTION Use the erase startup config command only for new systems If you enter this command on a system you have alr...

Страница 41: ...ality as an IP host port You cannot enable and run routing protocols on the management port The management port supports static routes and directly connected routes which are installed in the manageme...

Страница 42: ...r information on cabling a fiber optic module see Device connection For information on cleaning a fiber optic module see Device connection Connecting to a Network Device 42 Brocade NetIron CES 2000 Se...

Страница 43: ...ents To manage the system you need the following items for serial connection to the router A management station such as a PC running a terminal emulation application A straight through EIA TIA DB 9 se...

Страница 44: ...led plug the device into a nearby power source that adheres to the regulatory requirements outlined in this manual System power on page 57 5 Verify that the system LEDs are registering the proper LED...

Страница 45: ...GER Make sure the rack housing the device is adequately secured to prevent it from becoming unstable or falling over DANGER Mount the devices you install in a rack as low as possible Place the heavies...

Страница 46: ...e power supply is designed exclusively for use with the Brocade NetIron CES Series and Brocade NetIron CER Series devices The power supply produces extensive power Installing the power supply in a dev...

Страница 47: ...e com for a summary of supported cabling types and their specifications DANGER The intra building port or ports of the equipment or subassembly is suitable for connection to intra building or unexpose...

Страница 48: ...all it before mounting the device although the power supplies are hot swappable and can be installed or removed after the device is mounted and powered on This section provides the following procedure...

Страница 49: ...and insert the power supply into the empty power supply slot Press until the supply is completely in the slot so that the connectors on the back of the supply are fully engaged with the pins on the p...

Страница 50: ...r supply DANGER Before beginning the installation see the precautions in Power precautions Use the following procedures for DC power supplies in Brocade NetIron CES Series Brocade NetIron CER Series 2...

Страница 51: ...he slot so that the connectors on the back of the supply are fully engaged with the pins on the power backplane Installing an AC power supply on page 48 CAUTION Carefully follow the mechanical guides...

Страница 52: ...source NOTE Ensure that the DC return is isolated from the chassis ground DC I when connections to the power supply are made CAUTION For a DC system use a grounding wire of at least 6 American Wire G...

Страница 53: ...evice in a rack This section is also in the FGS HW Install Guide Any changes here should also be made there For rack mount installation Brocade recommends that you use the rack mount ears attached to...

Страница 54: ...position 5 Inch offset rack mount position FIGURE 42 5 Inch offset rack mount position 5 Inch offset rack mount position 54 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Instal...

Страница 55: ...Mid rack mount position FIGURE 43 Mid rack mount position Mid rack mount position Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 55 53 1003823 01...

Страница 56: ...Reverse rack mount position FIGURE 44 Reverse rack mount position Reverse rack mount position 56 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003823 01...

Страница 57: ...nding network or an isolated bonding network 3 Proceed to System power on page 57 You will need the following tools for installation 2 Phillips head screwdriver Four 10 24 screws or as specified by ra...

Страница 58: ...OSP or its wiring These interfaces are designed for use as intra building interfaces only Type 2 or Type 4 ports as described in GR 1089 CORE Issue 5 and require isolation from the exposed OSP cablin...

Страница 59: ...st below the console port labeled P1 P2 and Fn top to bottom to right LEDs for power and fan status for the 2024 models TABLE 9 LED Position State Meaning Fan labeled Fn Right side of front panel Gree...

Страница 60: ...The fan tray is powered on and is operating normal Amber or green blinking The fan tray is not plugged in Amber The fan tray is plugged in but one or more fans are faulty PS1 labeled P1 Left side of...

Страница 61: ...net or Brocade Network Advisor Attaching a PC or terminal Follow the steps given below to attach a management station using the serial port 1 Connect a PC or terminal to the serial port of the system...

Страница 62: ...settings listed above make sure the terminal emulation session is running on the same serial port you attached to the system The EIA TIA 232 serial communication port serves as a connection point for...

Страница 63: ...BaseT 100BaseTX Ethernet management port or from a Telnet or SSH connection to the PC or terminal You can initiate a local Telnet SSH or SNMP connection by specifying the management port s IP address...

Страница 64: ...of rows in your terminal emulation window For example if you display a list of all the commands at the global CONFIG level but your terminal emulation window does not have enough rows to display them...

Страница 65: ...d EXEC level moves to the User EXEC level For a complete list of CLI commands and syntax information for each command refer to Brocade Multi Service IronWare Configuration Guide Searching and filterin...

Страница 66: ...ow who exclude closed Console connections established you are connecting to this session 2 seconds in idle Telnet connections inbound 1 established client ip address 192 168 9 37 27 seconds in idle Te...

Страница 67: ...For example More next page Space next line Return key quit Control c telnet The results of the search are displayed searching telnet Telnet by name or IP address terminal Change terminal settings trac...

Страница 68: ...lowing regular expression matches output that contains the string abc followed by zero or more Xs abcX The plus sign matches on one or more sequential instances of a pattern For example the following...

Страница 69: ...le the following regular expression matches output that does not contain 1 2 3 4 or 5 1 5 The hyphen separates the beginning and ending of a range of characters A match occurs if any of the characters...

Страница 70: ...Using special characters in regular expressions 70 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003823 01...

Страница 71: ...6 A 30A Peak 25C DC 48 VDC 15 A 25A Peak 25C Table 14 provides the maximum power calculations Maximum power calculations at 100 240 VAC with two PSUs TABLE 14 Devices Watts BTUs per hour Brocade NetI...

Страница 72: ...ER Series 2024F 4X RT 219 747 Brocade NetIron CER Series 2024F 4X with 4x10G uplink installed 315 1076 Brocade NetIron CER Series 2024F 165 546 Brocade NetIron CER Series 2024F with 2x10G uplink insta...

Страница 73: ...cm 17 64 in44 8 cm 17 5 Brocade NetIron CES Series 2048C 1 RU1 7 inches4 4 cm 17 44 in44 3 cm 17 25 in43 9 cm 16 5 Brocade NetIron CES Series 2048CX 1 RU1 7 inches4 4 cm 17 44 in44 3 cm 17 25 in43 9...

Страница 74: ...nches4 4 cm 17 44 in44 3 cm 17 3 in43 9 cm 16 5 Brocade NetIron CER Series 2048FX 1 RU1 7 inches4 4 cm 17 44 in44 3 cm 17 3 in43 9 cm 17 5 Operating environment The following table Table 16 provides t...

Страница 75: ...60825 2 Safety of Laser Products Part 2 Safety of Optical Fibre Communications Systems CE EN60950 1 2006 TUV EN60950 1 2006 IEC EN60950 1 2005 Electromagnetic approvals FCC Part 15 Subpart B Class A...

Страница 76: ...ts The console port is a standard male DB 9 connector as shown in Console port pin assignments FIGURE 46 Console port pin and signalling details 1 Reserved 2 TXD output 3 RXD input 4 Reserved 5 GND 6...

Страница 77: ...s the connector s pin assignments Management port pin assignments TABLE 18 Pin number MDI X ports 1 TD 2 TD 3 RD 4 Not used 10BaseT CMT 100BaseTX 5 Not used 10BaseT CMT 100BaseTX 6 RD 7 Not used 10Bas...

Страница 78: ...Management port pin assignments 78 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003823 01...

Страница 79: ...ll or replace the following hardware components as needed Copper and fiber optic modules Power supplies Fan tray 2 x10 Gigabit Ethernet module only on the Brocade NetIron CES Series 2024C Brocade NetI...

Страница 80: ...es 2024C POWERS POWERS Power 1 3I50 AC 504W Installed OK Power 2 not present Total power budget for system 504 W FANS Metro fan tray fan 1 Status OK Speed MED 75 Metro fan tray fan 2 Status OK Speed M...

Страница 81: ...ply it may be easier to install it before mounting the device although the power supplies are hot swappable and can be installed or removed after the device is mounted and powered on Brocade recommend...

Страница 82: ...cord from the power supply 3 Unscrew the two power supply locking screws located at the top left and bottom right hand corner of the power supply FIGURE 49 Power supply screw location 1 Power supply...

Страница 83: ...ve the power supply or cover plate currently in the power supply bay you wish to install the power supply in Refer to Removing the AC power supply on page 81 for details 2 Remove the new power supply...

Страница 84: ...oving the DC power supply Required tools You will need the following tool to perform this procedure 2 Phillips head screwdriver The following procedures are required when removing an DC power supplies...

Страница 85: ...chment screws 2 Assembly screws 4 Unscrew the chassis attachment screws to unlock the power supply itself Required tools Hardware Maintenance Brocade NetIron CES 2000 Series and NetIron CER 2000 Serie...

Страница 86: ...beginning the installation refer to the precautions in Installing a DC power supply Use the following procedures for DC power supplies in Brocade devices Follow the steps given below to install an DC...

Страница 87: ...DC power supply 5 Use the wire tightening screws to secure the wires 6 Insert the DC connector with wires to the power supply and tighten the two assembly screws Hardware Maintenance Brocade NetIron...

Страница 88: ...back of the supply are fully engaged with the pins on the power backplane Installing the AC power supply on page 83 CAUTION Carefully follow the mechanical guides on each side of the power supply slo...

Страница 89: ...AWG wire should be attached to an agency approved crimp connector crimped with the proper tool The crimp connector should allow for securement to both ground screws on the enclosure For the Ground lu...

Страница 90: ...etected Green Steady Power supply 1 is installed and is functioning normally Green Blinking Power supply 1 has input power but is not enabled and has no output power PS2 labeled P2 Off Power supply 2...

Страница 91: ...CES Series 2024C Brocade NetIron CES Series 2024F Brocade NetIron CER Series 2024C Brocade NetIron CER Series 2024F units You can order the Brocade device with a 2 x10 Gigabit module installed at the...

Страница 92: ...thresholds All fans operate simultaneously at the same speed If a single fan fails within the assembly the fan tray should be replaced The fan tray is hot swappable If a Brocade device remains operat...

Страница 93: ...easons the ESD wrist strap should contain a series 1 megaohm resistor The protective covering that you removed from the copper or fiber optic module when you initially installed the module Follow the...

Страница 94: ...DANGER All fiber optic interfaces use Class 1 lasers DANGER For safety reasons the ESD wrist strap should contain a series 1 megaohm resistor Perform the following tasks to install a fiber optic modu...

Страница 95: ...terfaces only configure full C band tunable optics as shown below To configure a physical port enter a command such as the following device config if e10000 1 1 tunable optic sfpp channel 5 Syntax tun...

Страница 96: ...t using an SFP SFP or XFP connector make sure to keep the protective covering on Hardware Maintenance 96 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003...

Страница 97: ...product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Canadian requirements This Class A digital apparatus meets...

Страница 98: ...Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures China CC statement 98 Brocade NetIron CES 2000 Ser...

Страница 99: ...ation regulation 3 GPSGV the highest sound pressure level value is 60 0 dB A in accordance with EN ISO 7779 Maschinenl rminformations Verordnung 3 GPSGV der h chste Schalldruckpegel betr gt 60 0 dB A...

Страница 100: ...VCCI statement 100 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003823 01...

Страница 101: ...o los datos General cautions CAUTION Do not install the device in an environment where the operating ambient temperature might exceed 40 C 104 F VORSICHT Das Ger t darf nicht in einer Umgebung mit ein...

Страница 102: ...del cumplimiento de las normas la licencia del usuario para operar este equipo puede quedar anulada CAUTION Use the erase startup config command only for new systems If you enter this command on a sy...

Страница 103: ...drahtung und berlastschutz d rfen nicht durch das Ger t berbelastet werden Addieren Sie die Nennstromleistung in Ampere aller Ger te die am selben Stromkreis wie das Ger t installiert sind Somit k nne...

Страница 104: ...ugang wird von f r den Bereich zust ndigen Personen berwacht MISE EN GARDE Tous les dispositifs avec bloc d alimentation C C sont con us pour l installation dans des zones acc s r glement uniquement U...

Страница 105: ...e dispositif risque d tre endommag Le dispositive peut tre en train de fonctionner lorsque vous installez ou enlevez un bloc d alimentation mais le bloc d alimentation lui m me ne doit pas tre connect...

Страница 106: ...de entrada para la conexi n al producto deber ser catalogado de cobre 12 AWG marcado VW 1 y nominal para 90 grados Celsius CAUTION For a DC system use a grounding wire of at least 6 American Wire Gaug...

Страница 107: ...ise la terre de calibre AWG 6 13 mm minimum Ce fil de terre doit tre quip d un c t d un connecteur sertir agr fourni avec le ch ssis et l autre extr mit doit tre reli e la terre du b timent Ce connect...

Страница 108: ...RSICHT Alle Ger te mit Wechselstromquellen sind nur zur Installation in Sperrbereichen bestimmt Ein Sperrbereich ist ein Ort zu dem nur Wartungspersonal mit einem Spezialwerkzeug Schloss und Schl ssel...

Страница 109: ...e removing it from the chassis The fan may still be spinning at a high speed GEFAHR Die Finger d rfen nicht versehentlich in das Ventilatorblech gesteckt werden wenn dieses vom Geh use abgenommen wird...

Страница 110: ...enden die f r die Zertifizierung von Stromkabeln in Ihrem Land zust ndig ist Das Siegel ist Ihre Garantie dass das Stromkabel sicher mit Ihrem Ger t verwendet werden kann DANGER Si l installation n ce...

Страница 111: ...d Benutzen Sie dann das mit dem Ger t gelieferte Stromkabel um es an die Srromquelle anzuschlie en DANGER V rifiez que les circuits de sources d alimentation sont bien mis la terre puis utilisez lecor...

Страница 112: ...b timent intra building sont uniquement destin s une connexion en int rieur ou avec du c blage non expos aux intemp ries Il est rigoureusement interdit d tablir un contact m tallique entre le ou les p...

Страница 113: ...ere Ger te je nach Gewicht je schwerer desto tiefer dar ber untergebracht werden DANGER Montez les dispositifs que vous installez dans un b ti aussi bas que possible Placez le dispositif le plus lourd...

Страница 114: ...Danger Notices 114 Brocade NetIron CES 2000 Series and NetIron CER 2000 Series Hardware Installation Guide 53 1003823 01...

Страница 115: ...on 64 CONFIG Level 37 line editing 64 logging on 63 Privileged EXEC level 37 scroll control 64 securing access 37 combination ports 31 command disable 41 enable 41 show chassis 90 show interface manag...

Страница 116: ...n 2x10 gigabit Ethernet module 91 AC power supply 48 cabling 47 DC power supply 50 86 desktop 53 hardware 43 location 47 precautions 45 preparations 47 rack mount 53 redundant power supply 48 tasks 44...

Страница 117: ...leged EXEC level 37 product overviews 20 R rack mount installation 53 redundant power supplies 34 removing fiber optic module 93 removing a 2x10 gigabit Ethernet module 91 replacing a power supply 79...

Страница 118: ...ulation 61 U unpacking a system 43 upgrade packages 21 V VCCI statement 99 verifying operation 58 virtual interface assigning an IP address 40 W warnings listing 101 Weight warning 58 X XFPs 32 118 Br...

Отзывы: