Troubleshooting
•
Diagnosing switch indicators
TABLE 17
Troubleshooting chart
Symptom
Action
Power LED is Off
•
Check if internal power supply is disconnected.
•
Check connections between the device, the power cord, and the
wall outlet.
•
Contact Technical Support.
Power LED is Amber
Internal power supply has failed. Contact Technical Support.
Diag LED is Amber
•
The device self test has detected a fault.
•
Power cycle the device to try and clear the condition. If the
condition persists, contact Technical Support.
Link LED is Off
•
Verify that the device and attached device are powered on.
•
Be sure the cable is plugged into both the device and the
corresponding device.
•
Verify that the proper cable type is used and its length does not
exceed specified limits.
•
Check the adapter on the attached device and cable
connections for possible defects. Replace the defective adapter
or cable if necessary.
Installation
Verify that all system components have been properly installed. If one or more components appear to be malfunctioning (such as the
power cord or network cabling), test them in an alternate environment where you are sure that all the other components are functioning
properly.
Power and cooling problems
If the power indicator does not turn on when the power cord is plugged in, you may have a problem with the power outlet, power cord, or
internal power supply. However, if the unit powers off after running for a while, check for loose power connections, power losses or surges
at the power outlet, and use the
show chassis
command to verify that the temperature is below the shutdown threshold. If you still cannot
isolate the problem, then the internal power supply may be defective. In this case, contact Technical Support for assistance.
In-band access
You can access the management agent in the device from anywhere within the attached network using Telnet, or other network
management software. However, you must first configure the device with a valid IP address, subnet mask, and default gateway. If you
have trouble establishing a link to the management agent, check to see if you have a valid network connection. Then verify that you
entered the correct IP address. Also, be sure the port through which you are connecting to the device has not been disabled. If it has not
been disabled, then check the network cabling that runs between your remote location and the device.
Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide
Part Number: 53-1003617-03
97
Содержание ICX 6430 series
Страница 10: ...Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide 10 Part Number 53 1003617 03...
Страница 12: ...Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide 12 Part Number 53 1003617 03...
Страница 24: ...Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide 24 Part Number 53 1003617 03...
Страница 66: ...Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide 66 Part Number 53 1003617 03...
Страница 90: ...Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide 90 Part Number 53 1003617 03...
Страница 98: ...Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide 98 Part Number 53 1003617 03...
Страница 102: ...Brocade ICX 6430 and ICX 6450 Stackable Switches Hardware Installation Guide 102 Part Number 53 1003617 03...