Brocade 6520 Hardware Reference Manual
31
53-1002705-01
SFP transceiver removal and replacement
4
DRAFT: BROCADE CONFIDENTIAL
c. Gently push the fan into the chassis until it is firmly seated.
d. Using the Phillips-head screwdriver, secure the fan to the chassis by tightening the captive
screw.
FIGURE 11
Inserting the fan in the Brocade 6520
4. Verify that the fan status LED is steady green to indicate normal operation (see
Optionally, if using the command line interface (CLI), enter the fanShow command at the
command line prompt to display the status. You can also use the chassisShow command. The
power supply status can also be viewed using the Web Tools application.
SFP transceiver removal and replacement
Use the following procedure to remove and replace an 8 Gbps, 10 Gbps or 16 Gbps SFP+
transceiver.
DANGER
All fiber-optic interfaces use Class 1 lasers.
DANGER
Laser radiation. Do not view directly with optical instruments. Class 1 laser products.