POWER SUPPLY
The 415/240V power supply requirements for this machine are of a high level & unautho-
rized interference and/or inadequate maintenance could result in a situation that could put
the operator at risk. A qualified electrical engineer should always be assigned to maintain &
repair the system.
International Protection Rating code (Ingress Protection): IP54
First Digit: Solid - Level 5: Protected from limited dust ingress.
Second Digit: Liquid – Level 4: Protected from water spray from any direction.
SINGLE & THREE PHASE
Single phase
machines are provided with
three pins
, 15 amps rated plugs & leads for con-
nection to 240V, 50Hz power supply in Australia.
Active = Brown
Brown
VOLTAGE
MAIN
VOLTAGE
Neutral = Light Blue
Light Blue
240V/1
PH
240V
Earth = Green
Green
/Yellow
Yellow
Three phase
machines should be fitted with a suitable, approved
four pin plugs
Active = Brown
Brown
, White. Dark Blue
VOLTAGE
MAIN
VOLTAGE
Earth = Green
Green
/Yellow
Yellow
415V/3PH
415V/3PH
WARNING
Before connecting the machine to the power supply, check that the socket is not
connected in series with other machines. This condition is critical for the ideal op-
eration of the saw unit.