![Brobo 200HD Скачать руководство пользователя страница 44](http://html.mh-extra.com/html/brobo/200hd/200hd_product-and-maintenance-manual_2817130044.webp)
B r o b o P t y . L t d . D a n d e n o n g S o u t h
P l a n t R i s k A s s e s s m e n t R e p o r t
MARCH 2009
23
H A Z A R D R I S K A S S E S S M E N T M a k e : B r o b o 2 0 0 / 2 5 0 m m H D O H S S e r i e s b e n c h g r i n d e r
Manufacturers’ Serial Number. Group B29600 to B99999
H
AZARD
R
ISK
S
C
O
RE
C
ONTROL
A
CTION
T
AKEN
Y
/
N
R
E
-
SCORE
415/ 240 Volt Main
power supply
Inability to isolate power supply during cleaning or
maintenance, injury risk, electric shock, electrocution
risk to operator or repair personnel. Failure of circuit
protection to activate in the event of metallic frames
becoming live.
R
ISK
S
CORE
:
5:4:4
V
Introduce “Plug lockout calliper system” to isolation and “lockout” / “tagout” procedure to
site maintenance procedures. Attach site maintenance procedures to site safety induction
policy & induction for maintenance personnel. Include item to “Test & Tag” AS / NZS 3760
periodic test register. Carry out insulation leakage tests to all hazardous voltage, mains
power electric components and associated metal work. Check earth continuity / resistance to
all metal frames and attachments. Provide or repair earth points as necessary in accordance
with AS 3000 & AS/NZ 3760
Yes
See
2.1.5
5:2:3=M
415/240 Volt power
supply.
Electric shocks, burns, electrocution risks.
R
ISK
S
CORE
:
6:5:4
V
Fit “DANGEROUS VOLTAGE,” and or ISO international symbol signs to all access covers
over dangerous voltage areas of unit. Adequate warning of dangerous voltages within must
be provided at all areas.
Yes
See parts
list
6:1:2=L
Emergency stop
system.
In ability of operator to shut down plant in the event of
an emergency. Non compliance with Plant regulations
and AS 4024. Striking, crushing injury risks. Electric
shock risks, electrocutions risks.
R
ISK
S
CORE
:
5:4:4
V
Fit red coloured lock down type mushroom head emergency stop button with identification
and operating instruction signs, “PUSH TO STOP” located in the immediate proximity to
normal operator work stations. (Operator must be able to activate emergency stop from all
control stations and normal work positions. Emergency stop equipment circuitry must be
“fail safe” & comply with AS 1543, AS 4024 & AS 3000. The wiring of the emergency stop
system must comply with AS 4024.1 Section 6.3.7.1
Alternatively fit foot operated / kick type emergency stop system, and fit identification and
function sign.
Yes
See parts
list
5:1:3=L