4-2
ELECTRICAL HOOK-UP
Disconnect main power
supply and turn unit OFF
before installing power supply to the
unit. HIGH VOLTAGE may be encoun-
tered. Only persons trained and
equipped for checking high voltage shall
perform electrical connections.
Access For Hook-Up:
1. Disconnect main power supply.
2. Remove condensate pan and two
screws from bottom of front panel.
Pull out and down on bottom to
remove.
Phase Wiring:
Phase wiring diagram is located inside the
front panel.
Electric units are shipped from the factory
wired for 3 phase. In this case, applied
voltage must be connected to L1, L2
and L3 of contactor C1 and a ground
wire to the GND connector.
Unit Dimensions For Electrical Hook-Up:
Check all contactor screw
connections to be sure
they are fully tightened for proper electri-
cal continuity.
broaster.com Manual #17278 9/13 Rev 9/16
Содержание 2400 Series
Страница 2: ......
Страница 10: ...1 4 Hood Dimension In Millimeters broaster com Manual 17278 9 13 Rev 2 14 ...
Страница 12: ......
Страница 19: ...3 7 Wiring diagrams MODEL 2400GH DOMESTIC MODEL 2400GHXP EXPORT broaster com Manual 17278 9 13 Rev 10 15 ...
Страница 20: ...3 8 MODEL 2400GHCE UK broaster com Manual 17278 9 13 Rev 6 16 ...
Страница 23: ...4 3 2400E 208 or 240VAC broaster com Manual 17278 9 13 Rev 9 16 ...
Страница 24: ...4 4 EXPORT 2400E ST 220 380VAC to 240 415VAC broaster com Manual 17278 9 13 Rev 9 16 ...
Страница 25: ...4 5 EU 2400ECE ST 230 400V broaster com Manual 17278 9 13 Rev 10 15 ...
Страница 26: ......
Страница 30: ......
Страница 31: ......
Страница 32: ...Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...