3 - 2400GH INSTALLATION
3-1
GENERAL REQUIREMENTS
Failure to restrain the
fryer could allow it to
move, causing hot shortening to spill
out, or a possible break in the gas line
causing an explosive condition.
> Install and ANSI Z83.11/CSA 1.8 com-
pliant restraining device (such as Broaster
Company part number 17708) per manu-
facturers instructions.
Use appliance connec-
tors and quick-disconnect
devices that are in compliance with the
applicable ANSI and CSA standards.
> Attach an appliance connector to the
fryer according to the instructions provided
by the connector manufacturer.
> When installing or servicing the unit,
always check the dataplates, located
toward the rear of the countertop. This will
make certain proper parts are used and the
correct service rendered.
DO NOT
apply a
voltage to this unit other than that shown on
the dataplate. If in doubt, consult your local
power company.
> A remote circuit breaker or fuse should
be installed in main power supply located in
a path of exit and clearly identified.
> A gas shutoff valve, installed in gas
supply line, should be located in a path of
exit and clearly identified.
> Keep burner area free and clear of all
combustible materials.
>
DO NOT
obstruct exhaust flue or
open area around bottom of unit at the
front, back and sides which would restrict
the flow of combustion and ventilation air.
> Consult a local ventilation company to
insure an adequate air supply for all gas
fired equipment.
> US & Canada: Installation must con-
form with local codes, or in the absence of
local codes, with the National Fuel Gas
Code, ANSI Z223.1, Natural Gas Installation
Code, CAN/CGA-B149.1, or the Propane
Installation code, CAN/CGA-B149.2, as
applicable.
> The unit and its individual shut-off
valve must be disconnected from the gas
supply piping system during any pressure
testing of that system at test pressures in
excess of 1/2psi(3.45kPa).
> The unit must be isolated from the gas
supply piping system by closing its individ-
ual manual shut-off valve during any pres-
sure testing of the gas supply piping system
at test pressures equal to or less than 1/
2psi(3.45kPa).
broaster.com
Manual #17278 9/13 Rev 10/15
Содержание 2400 Series
Страница 2: ......
Страница 10: ...1 4 Hood Dimension In Millimeters broaster com Manual 17278 9 13 Rev 2 14 ...
Страница 12: ......
Страница 19: ...3 7 Wiring diagrams MODEL 2400GH DOMESTIC MODEL 2400GHXP EXPORT broaster com Manual 17278 9 13 Rev 10 15 ...
Страница 20: ...3 8 MODEL 2400GHCE UK broaster com Manual 17278 9 13 Rev 6 16 ...
Страница 23: ...4 3 2400E 208 or 240VAC broaster com Manual 17278 9 13 Rev 9 16 ...
Страница 24: ...4 4 EXPORT 2400E ST 220 380VAC to 240 415VAC broaster com Manual 17278 9 13 Rev 9 16 ...
Страница 25: ...4 5 EU 2400ECE ST 230 400V broaster com Manual 17278 9 13 Rev 10 15 ...
Страница 26: ......
Страница 30: ......
Страница 31: ......
Страница 32: ...Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...