3-2
ELECTRICAL HOOK-UP
WARNING:
Disconnect
main power supply and
turn unit OFF before installing power supply
to the unit.
High voltage
may be encoun-
tered. Only persons trained and equipped
for checking high voltage shall perform
electrical connections.
Access For Hook-Up:
1. Disconnect main power supply.
2. Remove condensate pan and one
screw (1600) or two screws (1800)
from bottom of front panel. Pull out
and down on bottom to remove.
Phase Wiring:
Phase wiring diagram is located inside the
front panel. See Access For Hook-Up
under ELECTRICAL HOOK-UP.
Electric units are shipped from the factory
wired for 3 phase. In this case, applied
voltage must be connected to L1, L2 and
L3 of contactor C1 and a ground wire to the
GND connector.
For single phase operation, remove both
element wires from the center connector of
contactor C2. Install wire #3 with wires #1
and #5 and install wire #2 with wires #4 and
#6. In this case, applied voltage must be
connected to L1 and L3 of contactor C1
and a ground wire to the GND connector.
3Ph 50/60Hz
1Ph. 50/60Hz
Note:
Check all contactor screw connections to be sure they are fully tightened for proper
electrical continuity.
broaster.com Manual #14678 1/99 Rev 2/14
Содержание 1600
Страница 2: ......
Страница 10: ...1 4 1800 Hood Dimensions In Inches broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 11: ...1 5 1600 1800 Hood Dimension In Millimeters broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 12: ......
Страница 16: ......
Страница 19: ...3 3 Unit Dimensions For Electrical Hook Up broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 22: ...3 6 1600 Mechanical 208 or 240VAC Effective E16A700023 E18A700043 broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 23: ...3 7 1600 Mechanical 208 or 240VAC Effective E16L700000 E18K700000 broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 24: ...3 8 1600 1800E Solid State 208 or 240VAC broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 27: ...3 11 1800E Solid State 208 or 240VAC Effective SE8I213193 2 5 1 3 4 6 broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 28: ...3 12 EXPORT 1600XP 1800EXP Mechanical broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 30: ...3 14 EXPORT 1600XP 1800EXP Mechanical Effective E16A700023 E18A700043 broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 31: ...3 15 EXPORT 1600XP 1800EXP Solid State broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 32: ...3 16 EXPORT 1600XP 1800EXP Solid State Effective SE6A700013 SE8A700011 broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 34: ...3 18 EU 1600CE MECHANICAL M C2 C1 TM broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 35: ...3 19 C2 EU 1600CE 1800ECE SOLID STATE broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 36: ...3 20 M C1 C2 R1 EU 1600UK 1800EUK SOLID STATE broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 37: ...3 21 1800E Solid State 480VAC broaster com Manual 14678 1 99 Rev 6 14 ...
Страница 39: ...3 23 EXPORT 1600XP Solid State 240 480VAC Effective SE6A700013 broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 41: ...3 25 EXPORT 1800EXP Solid State 480V Effective January 06 K60 broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 42: ......
Страница 45: ...4 3 EXPORT 1800GH Wiring Diagram broaster com Manual 14678 1 99 Rev 10 14 ...
Страница 46: ...4 4 1 2 2 1 2 1 1800GHCE Wiring Diagram broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 47: ...4 5 1800GHCE Wiring Diagram for the United Kingdom broaster com Manual 14678 1 99 Rev 2 14 ...
Страница 54: ......
Страница 55: ......
Страница 56: ...The Broaster Company 2855 Cranston Road Beloit WI 53511 3991 608 365 0193 broaster com ...