Mount housing anywhere between trusses, 

joists, or I-joists using hanger bars.

Sliding hanger bars are provided to allow for accurate positioning of hous-

ing anywhere between framing. They can be used on all types of framing 

(I-joist, standard joist, and truss construction) and span up to 24”.

Attach the MOUNTING CHANNELS to the housing using the 

SCREWS supplied. 

1

3b

Attach damper/duct connector.

Install 6-inch round ductwork.

TOP AND BOTTOM FLANGES 

REMAIN OUTSIDE OF HOUSING

SCREW FROM PARTS BAG

INSERT

TAB INTO 

SLOT IN 

HOUSING

1

4

1

5

Connect 6-inch round 

ductwork to damper / duct 

connector. Run ductwork to 

a roof cap or wall cap. Tape 

all ductwork connections to 

make them secure and air 

tight.

INSTALLATION STEPS

1

1

Some models only: 

Select 110, 130 or 150 

CFM based on your 

room size and 

desired 

air flow.

1

2

Plug-in and 

secure blower 

to housing.

Screws from 

parts bag

1

3a

Mount housing 

to joist.

SPACER

(use for 

mounting 

to I-Joist)

I-JOIST

Hold housing in place so 

that bottom edge of housing 

will be flush with finished 

surface of ceiling. For 

1/2” thick ceiling material, 

position bottom of each 

mounting flange flush with 

the bottom of joist. The 

housing mounts with four (4) screws or nails. Screw or nail 

housing to joist through lowest holes in each mounting flange,  

then through highest holes. NOTE: Mounting to I-JOIST (shown) 

requires use of SPACERS (included) between the highest hole of 

each mounting flange and the I-joist.

OR

Extend HANGER BARS to 

the width of the framing.
Hold housing in place 

so that bottom edge of 

housing will be flush with 

finished surface of ceiling.  

For 1/2” thick ceiling 

material, position bottom 

of each mounting flange 

flush with bottom of joist.

To ensure a noise-free 

mount: Secure hang-

ing bars together with 

SCREWS and use a pliers to 

crimp mounting channels 

tightly around hanger bars.

1

2

110  130  150

Содержание QT DC 110 CFM

Страница 1: ...sensor is mounted in the control housing The sensor will operate most reliably when cleaned occasionally as follows 1 Disconnect power at service entrance 2 Remove the grille Use a dry dustcloth clean...

Страница 2: ...ot install above or inside this area 45o 45o NOT FOR USE IN A COOKING AREA Housing mounted to I joists Use I joist spacer block provided Housing mounted anywhere between I joists using hanger bars Hou...

Страница 3: ...secure blower to housing Screws from parts bag 1 3a Mount housing to joist SPACER use for mounting to I Joist I JOIST Hold housing in place so that bottom edge of housing will be flush with finished s...

Страница 4: ...rts bag to secure wiring plate to fan housing Re install wiring panel and secure with screw from parts bag 3 4 1 2 1 3 2 1 3 2 ON OFF SWITCH PURCHASE SEPARATELY ON OFF SWITCH 120 VAC LINE IN SWITCH BO...

Страница 5: ...e suit de temps autre 1 Coupez le courant au panneau lectrique 2 Enlevez la grille l aide d un chiffon pousseter d une brosse dents propre ou d un aspirateur nettoyez d licatement le d tecteur et la g...

Страница 6: ...H0033F GRILLE BO TIER MAT RIAU DE PLAFOND C BLE LECTRIQUE BRIDES DE MONTAGE FERME IMPORTANT Les conduits allant de ce ventilateur jusqu l ext rieur de l habitation ont une grande influence sur le d bi...

Страница 7: ...EXT RIEUR DU BO TIER INS RER LA PATTE DANS LA FENTE DU BO TIER VIS PROVENANT DU SAC DE PI CES Certains mod les uniquement S lectionnez 110 130 ou 150 CFM en fonction des dimensions de la pi ce et du...

Страница 8: ...t rieur du bo tier d un c t comme de l autre 3 4 1 2 1 3 2 1 3 2 RGE INTERRUPTEUR MARCHE ARR T VENDU S PAR MENT INTERRUPTEUR MARCHE ARR T ENTR E 120 Vca BLANC FIL DE TERRE NOIR BLANC APPAREIL ORG NOIR...

Страница 9: ...ehumedadest montadoenlacubiertadecontrol Elfuncionamiento del sensor ser m s confiable si se limpia ocasionalmente Para ello haga lo siguiente 1 Desconecte la energ a en la entrada de servicio 2 Quite...

Страница 10: ...onductosm scortoyrectoposibleparaobtener undesempe o ptimoyeviteinstalarelventiladorconconductosmenoresque losrecomendados Elaislamientoalrededordelosconductospuedereducirla p rdida de energ a e inhib...

Страница 11: ...de tiro conducto Instale el conducto redondo de 6 pulgadas 1 4 1 5 Conecte el conducto redondo de 6 pulgadas al conector del regulador conducto Extienda el conducto hacia una tapa de techo o tapa de p...

Страница 12: ...e ubicar en la direcci n deseada Conecte los cables 3 4 1 2 1 3 2 1 3 2 ROJ L NEA DE ENTRADA DE 120 VCA CAJA DEL INTERRUPTOR BLANCO TIERRA BLANCO UNIDAD NEGRO BLANCO TIERRA BLANCO NEGRO BLANCO CONTROL...

Отзывы: