background image

NON-DUCTED RECIRCULATION FILTER
INSTALLATION

1. Remove the metal wires (Fig. 7) and discard them.
2. Install the Non-ducted recirculation Filter over the grease filter and

secure it with the metal wires supplied with the Non-ducted
recirculation Filter (Fig. 4).

WIRING

Note: This range hood must be properly grounded.

The unit should be installed by a qualified electrician in accor-
dance with all applicable national and local electrical codes.
Secure the conduit to the upper wiring hole through a conduit
connector.
Remove the (2) screws of the lateral wiring field cover and make
electrical connections. Connect both white leads to white supply lead
using suitable connector, connect black to black and green to green.

OPERATION

Controls

Light switch: turns the lamps on and off.

Blower switch: makes it possible to select the motor operating speed.
Position 0: motor off; Position I: motor lower speed; Position II: motor
high speed.

NON-DUCTED

RECIRCULATION

FILTER

INSTALL THE DUCTWORK

NOTE: To reduce the risk of fire, use only metal ductwork.

1. Decide where the ductwork will run between the hood and the

outside.

2. A straight, short duct run will allow the hood to perform most

efficiently.

3. Long duct runs, elbows, and transitions will reduce the performance

of the hood. Use as few of them as possible. Larger ducting may
be required for best performance with longer duct runs.

4. Install a roof or wall cap. Connect round metal ductwork to cap

and work back towards hood location. Use duct tape to seal the
joints between ductwork sections.

INSTALL THE HOOD

NOTE: the hood has to be installed, inside the cabinet, at minimum
1” from the rear wall cabinet and at 3” from the front wall cabinet.
The internal height of cabinet has to be minimum 16”.
The hood should be mounted centered over the cook top burners.

1. Cut a hole in the bottom of the cabinet, using the dimensions shown

in Fig. 2.

2. Take off the (4) “A” screws and remove the metal grid (Fig. 3).
3. NOTE: For installations where the Power Pack is less than 30”

above cook top, it is recommended that the Power Pack be
mounted into a metal liner or non-combustible material. This will
allow easier cleaning and provide protection to the cabinetry.

4. Insert the hood in the cabinet and secure with the (4) “B” mounting

screws 3.2x13mm (Fig. 3). For alternative side fixing use M4x15mm
screws with washers and nuts.

5. In the Non-Ducted Recirculation Configuration, install the Non-

ducted recirculation Filter before replacing the grid (see section
“Non-ducted recirculation filter installation”).

6. Replace the grid after wiring is completed.

ROOF CAP

ROUND

DUCT

POWER

MODULE

WALL

CAP

7”

ROUND
ELBOW

24” TO 30” ABOVE

COOKING SURFACE

10-1/4”

CUT A HOLE IN THE BOTTOM OF

THE CABINET

19-1/2”

GRID

LIGHT SWITCH

BLOWER SWITCH

FIG. 1

FIG. 2

FIG. 3

FIG. 4

FIG. 6

METAL WIRES

CONNECT DUCTWORK

Ducted Configuration
1. Use 7" round metal duct to connect the discharge collar on the

hood to the ductwork above. An optional 7” round damper may
be used (purchased seperately).

2. Use duct tape to make all joints secure and air tight.

Non-Ducted Recirculation Configuration
1. Connect a 7” round metal duct to the discharge opening so

that the air is sent outside the cabinet and sent back into the
room.

2. Use duct tape to make all joints secure and air tight.

LATERAL

WIRING FIELD

COVER

FIG. 5