Vent-A-Fume
Vent-A-Kiln Corp.
Custom-Designed Hood and Blower Systems/Variable Height Kiln Exhaust Systems
Bench Mounted Ventilator
(Assembly Instructions)
Note: a) Position of set screws for fittings (6), (7), (8) must be assembled as shown to avoid deflection of stand.
b) Horizontal support pipe (5) has two holes for J – bolt and 0.25” allen wrench.
Assembly:
Fasten flange (6) to work bench surface (
hardware not included
),
set screw to face equipment being vented, 0.25” dia. holes are
provided, larger holes may be drilled if desired. Insert 24.0” long
support pipe (5) into flange (6), tighten set
screw with 0.25” allen wrench provided.
Slide coupling (7) half way over end of
support pipe (5), set screws to face
equipment being vented, tighten set
screw. Insert 24.0” long support pipe
(5) into coupling (7), tighten set screw.
Slide crossover fitting (8) onto vertical
support pipe (5), set screw to face
down, tighten set screw and adjust
position as needed. Insert 24.0” long
horizontal support pipe (5) into
crossover fitting (8) (holes in
support pipe need to be in vertical
position as shown), tighten set screw and
adjust position as needed. Remove hex nuts
and washers from (2) blower inlet studs. Position
neoprene gasket (9) over blower studs and rest it
on top of inlet safety screen. Align blower inlet
studs with holes on top of collection hood (1), fasten
blower (2) to collection hood (1) with hex nuts and
washers. Mounting blower (2) and collection hood (1)
assembly to support stand is a
two person
task. Slide J – bolt
(12) into hole on blower hanging bracket and remove hex nut. Lift blower and collection hood
assembly while a helper guides the J – bolt through end hole in horizontal support pipe (5), fasten
with hex nut and adjust as needed to position blower outlet in desired location. Cut discharge hole
in wall, for 5.0” diameter hole dimensions square or round not to exceed 5.25”, 6.0” diameter duct
not to exceed 6.25”. Slide tail pipe onto louver (4) (sheet metal screws may be utilized to fasten
louver to tail pipe for tighter fit) and fasten louver (4) to outside wall (
hardware not included
).
System comes standard with 10 ft. of flexible hose, cut hose to shortest length permissible and
install utilizing zip clamps provided. Collection hood clearance should be 2.0” – 4.0” above oven
top for side swinging doors and collection hood should have enough clearance for vertical
swinging doors.
Any Questions or in need of assistance Please consult Factory