EZ80C 

  

Installation Guide

Page 2

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING: 

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the 
address or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten 
a prominent warning device, such as a tag, to the service 
panel.

3. Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 
to prevent backdrafting. Follow the heating equipment 
manufacturer’s guideline and safety standards such as those 
published by the National Fire Protection Association (NFPA), 
and the American Society for Heating, Refrigeration and 
Air Conditioning Engineers (ASHRAE), and the local code 
authorities.

5.  When cutting or drilling into a ceiling, do not damage electrical 

wiring and other hidden utilities.

6.  Ducted fans must always be vented to the outdoors.

7.  Acceptable for use over a tub or shower (in the ceiling only) 

when connected to a GFCI (Ground Fault Circuit Interrupter) 
- protected branch circuit.

8.  This unit must be grounded.

Typical Installation

CAUTION

1

.  For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

2.  DO NOT install this unit onto an acoustic ceiling panel.

3.  When installed in a sloped ceiling, the duct connector must 

point up.

4.  To avoid motor bearing damage and noisy and/or 

unbalanced  impellers, keep drywall spray, construction 
dust, etc. off power unit.

5.  Please read specification label on product for further 

information and requirements.

!

45°

45°

NOT FOR USE IN A COOKING AREA

 Do not install above or inside this area

Floor

Cooking
Equipment

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

ROUND

DUCT*

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP*

(with built-in

damper)

CEILING INSTALLATION SHOWN

Operation

To Operate Fan

Use an ON/OFF switch or speed control to operate this 
ventilator.

WARNING

 

Before servicing or cleaning unit, 

switch power off at service panel and lock the service 
disconnecting means to prevent power from being switched on 
accidentally. When the service disconnecting means cannot be 
locked, securely fasten a prominent warning device, such as a 
tag, to the service panel. 

Cleaning and Maintenance

To Clean

For quiet and efficient operation, long life and attractive 
appearance, remove grille and vacuum interior of unit with a 
dusting brush attachment.  

The motor is permanently lubricated and never needs oiling. If 
the motor bearings are making excessive or unusual noises, 
replace the motor.

Troubleshooting

Symptom: The fan does not run. 

•  Check for an open fuse or circuit breaker in the building’s 

service panel. 

•  Check that the plug-in connection for the motor is seated 

firmly in place. 

•  Check that the blower wheel spins freely.

Symptom: The fan runs erratically. 

•  Check that the blower wheel is firmly attached to the motor 

shaft and both spin freely. 

Symptom: The fan seems noisy. 

•  Check that the back draft damper in the fan’s duct connector 

pivots freely. Screws used to attach the ducting to the duct 
connector may be preventing the damper from opening. 

•  Check that the back draft damper in the wall or roof cap pivots 

freely. These dampers are sometimes mistakenly painted shut 
or obstructed by bird and insect debris. 

Содержание EZ80C

Страница 1: ...Register your product online at www broan ca register asp Easy installation Table of Contents Warnings and Cautions 2 Operation 2 Cleaning and Maintenance 2 Troubleshooting 2 Typical Installation 2 In...

Страница 2: ...earing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 5 Please read specification label on product for further information and requirements 45 45...

Страница 3: ...ound metal ducting recommended for best performance Use of other ducting is acceptable but may impact performance Roof cap or wall cap built in damper recommended Tape to seal duct connections Drywall...

Страница 4: ...N O F N E W F A N S D U C T C O N N E C T O R For retrofit installations Place this edge against ceiling framing See installation instructions Mark center line of existing fan on ceiling 2 Position t...

Страница 5: ...ceiling material to properly secure housing in place Minimum ceiling thickness to be 1 2 CAUTION Do not overtighten clamps with a power driver Ceiling material may become deformed and prevent proper...

Страница 6: ...e and wiring cover to inside of housing with screws provided Plug blower into receptacle and re install blower Tighten blower screws 7 Connect Electrical Wiring 8 Replace Blower 9 Install Grille Squee...

Страница 7: ...against ceiling framing with bottom edge of housing flush with finished ceiling Use 4 screws to attach housing to framing Optional for additional support After ceiling is finished rotate the tighteni...

Страница 8: ...sion is held to be prohibited or invalid such provision shall be ineffective only to the extent of such prohibition or invalidity without invalidating the remainder of such provision or the other rema...

Отзывы: