background image

MODELS  QP430SS • QP436SS • QP442SS

Page 1

WARNING 

 

CAUTION 

TO  REDUCE  THE  RISK  OF  FIRE,  ELECTRIC  SHOCK,  OR 

INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 

or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel  and  lock  the  service  disconnecting  means  to  prevent 

power from being switched on accidentally. When the service 

disconnecting  means  cannot  be  locked,  securely  fasten  a 

prominent warning device, such as a tag, to the service panel.

3.  Installation  work  and  electrical  wiring  must  be  done  by  a 

qualified  person(s)  in  accordance  with  all  applicable  codes 

and standards, including fire-rated construction.

4.  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 

to  prevent  backdrafting.  Follow  the  heating  equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and  the  American  Society  of  Heating,  Refrigeration  and 

Air  Conditioning  Engineers  (ASHRAE),  and  the  local  code 

authorities.

5.  This product may have sharp edges. Be careful to avoid cuts 

and abrasions during installation and cleaning.

6.  When  cutting  or  drilling  into  wall  or  ceiling,  do  not  damage 

electrical wiring and other hidden utilities.

7.  Ducted fans must always be vented to the outdoors.
8.  Use only metal ductwork.
9.  Do not use this fan with any solid-state speed control device.
10. As  an  alternative,  this  product  may  be  installed  with  the 

UL-approved  cord  kit  designated  for  the  product,  following 

instructions packed with the cord kit.

11. This unit must be grounded.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

1.  Never  leave  surface  units  unattended  at  high  settings. 

Boilovers  cause  smoking  and  greasy  spillovers  that  may 

ignite. Heat oils slowly on low or medium settings.

2.  Always  turn  hood  ON  when  cooking  at  high  heat  or  when 

flambéing  food  (i.e.  Crepes  Suzette,  Cherries  Jubilee, 

Peppercorn Beef Flambé).

3.  Clean  ventilating  fans  frequently.  Grease  should  not  be 

allowed to accumulate on fan or filter.

4.  Use proper pan size. Always use cookware appropriate for the 

size of the surface element.

TO  REDUCE THE  RISK  OF  INJURY TO  PERSONS  IN THE 

EVENT  OF  A  RANGE TOP  GREASE  FIRE,  OBSERVE THE 

FOLLOWING:*

1.  SMOTHER  FLAMES  with  a  close-fitting  lid,  cookie  sheet, 

or  metal  tray,  then  turn  off  the  burner.  BE  CAREFUL  TO 

PREVENT BURNS. If the flames do not go out immediately, 

EVACUATE AND CALL THE FIRE DEPARTMENT.

EVOLUTION

TM

 4

QP4 Series Range Hoods

READ AND SAVE THESE INSTRUCTIONS

 FOR DOMESTIC COOKING ONLY 

WARNING 

 

2.  NEVER PICK UP A FLAMING PAN — You may be burned or 

spread the fire.

3.  DO NOT USE WATER, including wet dishcloths or towels - a 

violent steam explosion will result.

4.  Use an extinguisher ONLY if:

A.  You know you have a Class ABC extinguisher, and you 

already know how to operate it.

B.  The fire is small and contained in the area where it started.
C.  The fire department is being called.
D.  You can fight the fire with your back to an exit.

* Based on “Kitchen Firesafety Tips” published by NFPA.

1.  For indoor use only.
2.  For  general  ventilating  use  only.  Do  not  use  to  exhaust 

hazardous or explosive materials and vapors.

3.  To avoid motor bearing damage and noisy and/or unbalanced 

impeller, keep drywall spray, construction dust, etc., off power 

unit.

4.  Do  not  use  over  cooking  equipment  greater  than  70,000 

BTU/hr. as the blower motor will shut down intermittantly.

5.  Your  hood  motor  has  a  thermal  overload  which  will 

automatically shut off the motor if it becomes overheated. The 

motor will restart when it cools down. If the motor continues 

to shut off and restart, have the hood serviced.

6.  The top of the hood MUST NOT BE LESS than 30” and at a 

maximum of 36” above cooktop for best capture of cooking 

impurities.

7.  This hood is not intended to be used as a shelf.
8.  Please  read  specification  label  on  product  for  further 

information and requirements.

Register your product online at: www.broan.com

Installer: Leave this manual 

with the homeowner.

Homeowner: Cleaning, Maintenance and 

Operating instructions on page 2.

Содержание EVOLUTION QP430SS

Страница 1: ...ng at high heat or when flamb ing food i e Crepes Suzette Cherries Jubilee Peppercorn Beef Flamb 3 Clean ventilating fans frequently Grease should not be allowed to accumulate on fan or filter 4 Use p...

Страница 2: ...urn the boost speed off NOTE This hood utilizes an offset blower design to achieve greater performance and lower sound levels As a result you may notice that cooking impurities are more attracted to o...

Страница 3: ...ly CLOCK SETTING Press the button once the hours will begin blinking in the LED screen Use the and buttons to set the appropriate hours for the clock A small indicator will illuminate in the left corn...

Страница 4: ...blown additional diagnostics are needed MAIN FUSE RANGE HOOD CONTROL BOARD LIGHT FUSE REMOTE CONTROL The hood is compatible with Broan RF Remote Control Model BCR1 optional Purchase separately HEAT SE...

Страница 5: ...HOOD HOOD 1 Determine whether hood will discharge vertically 3 x 14 or 7 Round or horizontally 3 x 14 only For vertical or horizontal discharge run ductwork between the hood location and a roof cap or...

Страница 6: ...ter and the 7 round duct plate can be installed up to on either side of the hood center Install the 3 x 14 Damper Duct Connector with the Damper Flap Pivot nearest the Top Back Edge of Hood TOP BACK E...

Страница 7: ...l Power Cable Knockout from top or back of hood ELECTRICAL POWER CABLE KNOCKOUT CONNECT THE WIRING HOWTO CHANGE LIGHT BULBS Install 4 Halogen Bulbs included with hood Use 120 V 50 W shielded halogen b...

Страница 8: ...ich is found to be defective under normal use and service THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS TUBES HALOGEN AND INCANDESCENT BULBS FUSES FILTERS DUCTS ROOF CAPS WALL CAPS AND OT...

Отзывы: