17
4. CONTROLS
(
CONT
’
D
)
4.2 E
LECTRICAL
C
ONNECTION
TO
O
PTIONAL
W
ALL
C
ONTROLS
(
CONT
'
D
)
4.2.1 E
LECTRICAL
C
ONNECTION
TO
VT4W M
AIN
W
ALL
C
ONTROL
NO C NC I OC OL Y R G B
B
G
Y
VT4W
MAIN WALL CONTROL
REAR VIEW
G B
Y
VE0327A
4.2.2 E
LECTRICAL
C
ONNECTION
TO
O
PTIONAL
A
UXILIARY
W
ALL
C
ONTROLS
NOTE: If an optional auxiliary wall control
is activated and then, the Humidity
Control is being activated, this
one will override the auxiliary wall
control commands.
NO C NC I OC OL Y R G B
20-MINUTED LIGHTED PUSH BUTTON
(5 MAXIMUM)
60-MINUTE
CRANK TIMER
HUMIDITY CONTROL
VE0110A
COM
FOR T ZO
N E
O
FF
%
REL
ATIVE HUMIDIT
Y
70%
60%
50%
40%
30%
25%
20%
HUMIDITY
CONTROL
Once the wall control(s) connections have been made, insert the terminal connector in the bottom of the unit, on the electrical compartment
front face.
WARNING
Risk of electric shock. Before performing
any maintenance or servicing, always
disconnect the unit from its power source.
AVERTISSEMENT
Danger d’électrocution. Débranchez
toujours l’appareil avant d’entreprendre
des travaux d’entretien ou de réparation.
CAUTION
Unscrew both screws to open the electrical
compartment. To completely remove, detach
from its retention wire inside.
ATTENTION
Dévisser les deux vis pour ouvrir le compartiment
électrique. Pour retirer complètement, le
détacher de son fil de rétention intérieur.
No light OFF or remote controled
Amber light LOW speed
Green ligh HIGH speed
Blinking light See User Manual
Sans lumière Arrêté ou contrôlé
par contrôle mural
Lumière ambre Basse vitesse
Lumière verte Haute vitesse
Clignotant Voir guide d’utilisation
VD0182
T
ERMINAL
CONNECTOR
4.3 VT4W
O
PTIONAL
M
AIN
W
ALL
C
ONTROL
O
PERATION
INTERMITTENT
MAX
MIN
VC0070
VT4W
C
OLOR
M
ODE
S
UGGESTED
USE
GREEN
Intermittent
Select this mode when you are away
from the house for a few days. Also,
when you deem the inside air is too
dry in heating season, or too humid
during cooling season. In this mode,
the unit is OFF for 40 minutes per
hour and ventilates at minimum
speed the remaining 20 minutes of
the hour.
YELLOW
Min speed ventilation
For normal daily operation.
RED
Max speed ventilation
For excess pollutants and humidity
(parties, odors, smoke, etc.).
No light
Off
To perform maintenance.
NOTE: On some older wall control model, the left
terminal is identified
OC
instead of
Y
; connect
this terminal to
Y
on terminal connector.