11
INTERNAL BLOWER: Run power cable to installation location. Remove wiring cover and place the hood in its location. Mark the position
of the screws (smaller part of the key holes [
A
]) with a pen. Remove the hood and install the four 1/2" double thread screws at marked
positions, leaving a 1/8" gap. You may use up to eight key holes and screws for wider hoods and double blower hoods. Insert the cable
in the hood through the wire clamp and tighten the wire clamp to secure the cable. Place the hood under the cabinet and slide it into
position. Make sure the adapter (or the transition) enters the ducting. Secure the hood by tightening the screws completely. Install the last
1/2" double thread screws in the remaining holes [
B
].
Remove wiring cover from rough-in plate or electrical compartment and set aside.
INTERNAL BLOWERS
: Connect cable into wiring box using wire connectors.
Connect BLACK to BLACK, WHITE to WHITE and GREEN
or bare wire under GREEN ground screw.
Reinstall
wiring
cover.
IN-LINE OR EXTERIOR BLOWERS
: See instructions included with blower.
9. INSTALL THE HOOD
(ALL BLOWERS)
10. CONNECT WIRING
(ALL BLOWERS)
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
!
CAUTION
The ORANGE wire (A) is for make-up air device connection only. If
there is no make-up air device, never remove the cap on the ORANGE
wire end.
HE0088
A
HD0265
A
B
A
B
B
INTERNAL
BLOWER
HOOD
EXTERIOR
OR
IN
-
LINE
BLOWER
HOOD
EXTERIOR OR IN-LINE BLOWER: Run power cable to installation location. Place the hood in its location. Mark the position of the screws
(smaller part of the key holes [
A
]) with a pen. Remove the hood and install the 4 1/2" double thread screws at marked positions, leaving a
1/8" gap. Remove wiring cover on top of the hood, punch-out the electrical knock-out and install the wire clamp. Insert the cable in the hood
through the wire clamp and tighten the wire clamp to secure the cable. Connect wiring (see instructions included with exterior or in-line
blower). Place the hood under the cabinet and slide it in position. Secure the hood by tightening the screws completely. Install the last
1/2" double thread screws in the remaining holes [
B
].
Refer to instructions included with blower.
Plug the 3-prong plug cord from rough-in plate to the 3-prong male connector inside
the hood (
A
) and the 2-prong male connector cord from rough-in plate to the 2-prong plug
inside the hood (
B
).
11. INSTALL THE BLOWER
(EXTERIOR OR IN-LINE BLOWER)
WARNING
!
Do not plug the 2 cords together.
HE0078
B
A