background image

2

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR 
INJURY TO PERSONS, OBSERVE THE FOLLOWING:

1.

  Use this unit only in the manner intended by the manufacturer. 

If you have questions, contact the manufacturer at the address 
or telephone number listed in the warranty.

2.

  Before servicing or cleaning unit, switch power off at service 

panel and lock service disconnecting means to prevent 
power from being switched on accidentally. When the service 
disconnecting means cannot be locked, securely fasten a 
prominent warning device, such as a tag, to the service panel.

3.

 Installation work and electrical wiring must be done by 

qualified personnel in accordance with all applicable codes 
and standards, including fire-rated construction codes and 
standards.

4.

  Sufficient air is needed for proper combustion and exhausting 

of gases through the flue (chimney) of fuel burning equipment 
to prevent backdrafting. Follow the heating equipment 
manufacturer’s guidelines and safety standards such as 
those published by the National Fire Protection Association 
(NFPA) and the American Society for Heating, Refrigeration 
and Air Conditioning Engineers (ASHRAE) and the local code 
authorities.

5.

  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

6.

  Ducted fans must always be vented outdoors.

7.

  Do not use this unit with any additional solid-state speed 

control device.

8.

  To reduce the risk of fire, use only metal ductwork.

9.

  This unit must be grounded.

10.

 

When applicable local regulations comprise more 
restrictive installation and/or certification requirements, 
the aforementioned requirements prevail on those of this 
document and the installer agrees to conform to these at his 
own expenses.

TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:

a)

  Never leave surface units unattended at high settings. Boilovers 

cause smoking and greasy spillovers that may ignite. Heat oils 
slowly on low or medium settings.

b)

 Always turn hood ON when cooking at high heat or when 

flambeing food (i.e.: Crêpes Suzette, Cherries Jubilee, 
Peppercorn Beef Flambé).

c)

  Clean ventilating fans frequently. Grease should not be allowed 

to accumulate on fan, filters or in exhaust ducts.

d)

  Use proper pan size. Always use cookware appropriate for the 

size of the surface element.

1.

  For indoor use only.

2.

 For general ventilating use only. Do not use to exhaust 

hazardous or explosive materials and vapors.

3.

  To avoid motor bearing damage and noisy and/or unbalanced 

impellers, keep drywall spray, construction dust, etc. off power 
unit.

4.

  Your hood motor has a thermal overload which will automatically 

shut off the motor if it becomes overheated. The motor will 
restart when it will be cooled down. If the motor continues to 
shut off and restart, have the hood serviced.

5.

  For best capture of cooking impurities, the bottom of the hood 

should be at a minimum of 24” and at a maximum of 30” above 
the cooking surface. 

For a gas range

, the bottom of the hood 

MUST NOT BE LESS than 30” above cooktop.

6.

  Two installers are recommended because of the large size and 

weight of this hood.

7.

  To reduce the risk of fire and to properly exhaust air, be sure to 

duct air outside — Do not exhaust air into spaces within walls 
or ceiling or into attics, crawl space or garage. 

8.

  This product is equipped with a thermostat which may start 

blower automatically. To reduce the risk of injury and to prevent 
power from being switched on accidentally, switch power off at 
service panel and lock or tag service panel.

9.

  Because of the high exhausting capacity of this hood, you 

should make sure enough air is entering the house to replace 
exhausted air. Use an appropriate make-up air device or open 
a window  close to or in the kitchen.

10.

 To reduce the risk of fire and electric shock, the Broan Elite 

E64E Series hood must be installed with one Broan exterior 
blower model 331H, 332H, 335 or 336; or one Broan in-line 
blower model HLB3, HLB6, HLB9 ou HLB11. Other blowers 
cannot be substituted. (Exterior or in-line blowers sold 
separately.)

11.

 

Please read specification label on product for further 
information and requirements.

    WARNING

CAUTION

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE 
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE 
THE FOLLOWING*:

1.

  SMOTHER FLAMES with a close-fitting lid, cookie sheet or 

metal tray, then turn off the burner. BE CAREFUL TO PREVENT 
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY, 
EVACUATE AND CALL THE FIRE DEPARTMENT.

2.

  NEVER PICK UP A FLAMING PAN — You may be burned.

3.

  DO NOT USE WATER, including wet dishcloths or towels — 

This could cause a violent steam explosion.

4.

  Use an extinguisher ONLY if:

 

A.

 You own a Class ABC extinguisher and you know how to 

operate it.

 

B.

 The fire is small and contained in the area where it started.

 

C.

 The fire department has been called.

 

D.

 You can fight the fire with your back to an exit.

* Based on "Kitchen Fire Safety Tips" published by NFPA.

    WARNING

Содержание E64000LC SERIES

Страница 1: ...ND SAVE THESE INSTRUCTIONS Broan NuTone Canada ULC Mississauga Ontario www broan ca 877 896 1119 REGISTER YOUR PRODUCT ONLINE AT www broan ca INTENDED FOR DOMESTIC COOKING ONLY INSTALLER LEAVE THIS MANUAL WITH HOMEOWNER HOMEOWNER USE AND CARE INFORMATION ON PAGES 13 14 ...

Страница 2: ...nly Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impellers keep drywall spray construction dust etc off power unit 4 Yourhoodmotorhasathermaloverloadwhichwillautomatically shut off the motor if it becomes overheated The motor will restart when it will be cooled down If the motor continues to shut off and restart have ...

Страница 3: ...RIGHT MODEL 453 4 X 18 TO 10 ROUND HORIZ LEFT ADAPTER 4 X 18 SUPPLIED WITH DOUBLE BLOWER HOOD DOUBLE BLOWER 1100 CFM E64000LC SERIES HOOD RMP SERIES BACKSPLASH STAINLESS STEEL WALL COVERING WITH WARMING SHELVES OPTIONAL SINGLE BLOWER 600 CFM ADAPTER DAMPER 3 X 10 SUPPLIED WITH SINGLE BLOWER HOOD STANDARD DUCT 3 X 10 MODEL 639 3 X 10 WALL CAP MODEL 413 TRANSITION 3 X 10 TO 8 8 ROUND STANDARD DUCT 8...

Страница 4: ...DUCT 2FT SECTIONS MODEL HLB9 800 CFM OR HLB11 1100 CFM IN LINE BLOWER INCLUDES TWO 8 X 12 TO 10 ROUND TRANSITIONS MODEL 331H 600 CFM OR 332H 900 CFM EXTERIOR BLOWER MODEL 335 1200 CFM OR 336 1500 CFM EXTERIOR BLOWER MODEL 421 10 ROUND VERT IN LINE DAMPER RECOMMENDED FOR USE WITH EXTERIOR BLOWERS 332KR IN LINE AND EXTERIOR BLOWER ROUGH IN KIT SUPPLIED WITH HOOD RMP SERIES BACKSPLASH STAINLESS STEEL...

Страница 5: ...3 4 9 and up of this manual Install proper sized ductwork elbows and roof or wall cap for the type of blower you are installing If using 7 8 or 10 round ducts use a transition internal blower s only Use 2 metal foil duct tape to seal duct joints We recommend to install the hood at a minimum distance of 24 from an electric range and at 30 from a gas range Distances over 30 are at the installer and ...

Страница 6: ...332KR mounted inside all external blower hoods Bag of parts including 1 wire clamp 9 no 8 x 1 2 2 wire connectors 8 no 8 32 x 1 4 mechanical screws 4 no 8 x 3 8 screws Parts sold separately In line blower assembly HLB3 HLB6 HLB9 or HLB11 all include transition Exterior blower assembly 331H 332H 335 or 336 RMP Series Backsplash optional Transitions duct elbows dampers wall or roof cap Refer to page...

Страница 7: ...le to install the backsplash make sure you have at least 18 clearance between bottom of hood and range control panel or cooktop See instructions packed with backsplash L C CABINET BOTTOM VIEW 22 10 10 INTERNAL DOUBLE BLOWER HOOD HD0656A L C B CABINET BOTTOM VIEW 5 5 3 A INTERNAL SINGLE BLOWER HOOD L C INTERNAL SINGLE BLOWER HOOD 2 B 3 5 5 A L C 22 INTERNAL DOUBLE BLOWER HOOD 5 10 10 7 8 5 3 4 L C ...

Страница 8: ... the adapter is sent unfold See at right NOTE For 36 and 42 wide double blower hoods the adapter is taped on top of the filters Remove adapter and set aside before removing filters A Remove tape on filters Remove filters from hood and set aside NOTE It is recommended to start with the middle filter s B Lift out grease drip rail 1 and set aside SINGLE BLOWER HOOD Remove both screws retaining the ad...

Страница 9: ...out the appropriate electrical knockout hole on top A or back B of the hood Install the wire clamp included in parts bag 1 2 3 HR0021 1 2 3 HR0024 A B 7 HORIZONTAL DISCHARGE INSTALLATION INTERNAL BLOWER S ONLY All internal blower hoods are factory shipped with the blower s mounted for a vertical discharge configuration For a horizontal discharge configuration disassemble the blower s from the inne...

Страница 10: ...ed transition and seal the joints with metal foil duct tape 7 HORIZONTAL DISCHARGE INSTALLATION INTERNAL BLOWER S ONLY CONT D Slide the blower to disengage its flange from the retaining bracket HD0270 Flip the blower and engage its flange in the back wall retaining bracket Using a 5 16 socket and the screws previously removed secure the blower to the hood Plug the blower in NOTE FOR DUAL BLOWER HO...

Страница 11: ...andards Before connecting wires switch power off at service panel and lock service disconnecting means to prevent power to be switched on accidentally CAUTION The ORANGE wire A is for make up air device connection only If there is no make up air device never remove the cap on the ORANGE wire end HE0088 A HD0265 A B A B B INTERNAL BLOWER HOOD EXTERIOR OR IN LINE BLOWER HOOD EXTERIOR OR IN LINE BLOW...

Страница 12: ...1 2 It is recommended to install side filters first and finish with middle one s 1 Insert one end of the filter into the upper channel of the hood 2 Raise the other end towards the inside of hood and insert in the grease drip rail of the hood 12 LED LIGHTING WARNING Do not touch lamps during or soon after operation Burns may occur Cannot be replaced by any other type of light bulb or LED module Th...

Страница 13: ...move stubborn dirt Use any harsh or abrasive cleansers Allow dirt to accumulate Let plaster dust or any other construction residues reach the hood During construction renovation cover the hood to make sure no dust sticks to stainless steel surface Avoid when choosing a detergent Any cleaners that contain bleach will attack stainless steel Any products containing chloride fluoride iodide bromide or...

Страница 14: ...N NUTONE S OBLIGATION TO REPAIR OR REPLACE AT BROAN NUTONE S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Some provinces do not allow the exclusion or limitation of incidental or consequential damages so the above limitati...

Страница 15: ...TIONAL SECOND BLOWER MOTOR HE0207A LED DRIVER LED LED BRN GRY LED CONTROL IN J1 J2 OUT WHT WHT SPEED CONTROL HEAT SENTRY THERMOSTAT BLU BLK BLK BLU GRY WHT BLK YEL BLK ORA NEON ORA M REMOTE BLOWER ASSEMBLY RETURN LINE 120 V SUPPLY ROUGH IN PLATE FAN SWITCH USE ONLY WITH APPROPRIATE MAKE UP AIR SYSTEM GROUND HE0208A COLOR CODE Off 2 On 3 1 BLK BLK WHT BLK GRN WHT WHT WHT GRN BLK LED DRIVER LED LED ...

Страница 16: ...1 1 8 SV17600 SV17603 BAFFLE FILTER 8 84 x 15 125 BAFFLE FILTER 11 84 X 15 125 2 1 3 2 2 4 9 SV07680 BAFFLE FILTER HANDLE WITH SCREWS 3 3 4 4 10 SV08355 BLOWER AND LIGHT KNOBS 2 KNOBS 1 1 1 1 11 SV21722 SPEED CONTROL 1 1 1 1 12 SV21248 LIGHT CONTROL WITH NUT 1 1 1 1 13 SV08339 BLOWER ROCKER SWITCH 1 1 1 1 14 SV08093 PILOT LAMP ASS Y 1 1 1 1 15 SV06750 BROAN ELITE LOGO 1 1 1 1 SV21242 INSTALLATION ...

Отзывы: