background image

CBD3 SERIES

Page 1

WARNING  

 

CAUTION  

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN-

JURY TO PERSONS, OBSERVE THE FOLLOWING:
1.  Use this unit only in the manner intended by the manufac-

turer. If you have questions, contact the manufacturer at the 

address or telephone number listed in the warranty.

2.  Before servicing or cleaning unit, switch power off at service 

panel and lock the service disconnecting means to prevent 

power from being switched on accidentally. When the ser-

vice disconnecting means cannot be locked, securely fasten 

a prominent warning device, such as a tag, to the service 

panel.

3.  Installation work and electrical wiring must be done by a 

qualified person(s) in accordance with all applicable codes 

and standards, including fire-rated construction.

4.  Sufficient air is needed for proper combustion and exhaust-

ing of gases through the flue (chimney) of fuel burning equip-

ment to prevent backdrafting. Follow the heating equipment 

manufacturer’s guideline and safety standards such as those 

published by the National Fire Protection Association (NFPA), 

and the American Society of Heating, Refrigeration and Air 

Conditioning Engineers (ASHRAE), and the local code au-

thorities.

5.  This product may have sharp edges. Be careful to avoid cuts 

and abrasions during installation and cleaning.

6.  When cutting or drilling into wall or ceiling, do not damage 

electrical wiring and other hidden utilities.

7.  Ducted fans must always be vented to the outdoors.
8.  Use only metal ductwork.
9.  Do not use this fan with any solid-state speed control device.
10. As an alternative, this product may be installed with the UL-

approved cord kit designated for the product, following in-

structions packed with the cord kit.

11. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1.  Never leave surface units unattended at high settings. 

Boilovers cause smoking and greasy spillovers that may ig-

nite. Heat oils slowly on low or medium settings.

2.  Always turn hood ON when cooking at high heat or when 

flambéing food (i.e. Crepes Suzette, Cherries Jubilee, Pep-

percorn Beef Flambé).

3.  Clean ventilating fans frequently. Grease should not be al-

lowed to accumulate on fan or filter.

4.  Use proper pan size. Always use cookware appropriate for 

the size of the surface element.

TO REDUCE THE RISK OF INJURY TO PERSONS IN THE 

EVENT OF A RANGE TOP GREASE FIRE, OBSERVE THE 

FOLLOWING:*
1.  SMOTHER FLAMES with a close-fitting lid, cookie sheet, 

or metal tray, then turn off the burner. BE CAREFUL TO 

PREVENT BURNS. If the flames do not go out immediately, 

EVACUATE AND CALL THE FIRE DEPARTMENT.

CBD3 Series

Range Hoods

READ AND SAVE THESE INSTRUCTIONS

  FOR DOMESTIC COOKING ONLY  

WARNING  

 

2.  NEVER PICK UP A FLAMING PAN — You may be burned or 

spread the fire.

3.  DO NOT USE WATER, including wet dishcloths or towels - a 

violent steam explosion will result.

4.  Use an extinguisher ONLY if:

A.  You know you have a Class ABC extinguisher, and you 

already know how to operate it.

B.  The fire is small and contained in the area where it started.
C.  The fire department is being called.
D.  You can fight the fire with your back to an exit.

* Based on “Kitchen Firesafety Tips” published by NFPA.

1.  For indoor use only.
2.  For general ventilating use only. Do not use to exhaust haz-

ardous or explosive materials and vapors.

3.  To avoid motor bearing damage and noisy and/or unbal-

anced impeller, keep drywall spray, construction dust, etc., 

off power unit.

4.  Do not use over cooking equipment greater than 60,000 

BTU/hr.

5.  Your hood motor has a thermal overload which will automati-

cally shut off the motor if it becomes overheated. The motor 

will restart when it cools down. If the motor continues to shut 

off and restart, have the hood serviced.

6.  A maximum height of 24” above the cooktop is recommend-

ed for best capture of cooking impurities. The bottom of the 

hood MUST NOT BE LESS than 18” above the cooktop.

7.  Please read specification label on product for further infor-

mation and requirements.

Installer: Leave this manual 

with the homeowner.

Homeowner: Cleaning, Maintenance and 

Operating instructions on page 2.

NOTE  If hood is to be installed non-ducted:

Purchase non-ducted filter (Model BPQTF) from your 

local distributor or retailer.

Register your product online 

at: www.broan.com

Содержание CBD3 Series

Страница 1: ...food i e Crepes Suzette Cherries Jubilee Pep percorn Beef Flamb 3 Clean ventilating fans frequently Grease should not be al lowed to accumulate on fan or filter 4 Use proper pan size Always use cookw...

Страница 2: ...TERS section for removal and installation instructions Non ducted Recirculation Filter The non ducted recirculation filter should be changed every 3 6 months Replace more often if your cooking style g...

Страница 3: ...TING PREPARE HOOD LOCATION SOFFIT 18 24 ABOVE COOKING SURFACE CABINET 3 X 10 DUCT For horizontal discharge WALL CAP ROOF CAP 3 X 10 or 7 ROUND DUCT For vertical discharge HOUSE WIRING Top or Back of h...

Страница 4: ...he tab down and lifting filter out 7 Remove all protective polyfilm from the hood stainless steel hoods only ALUMINUM FILTER 1 PULL DOWN 2 LIFT OUT BAFFLE SCREWS 13 Remove 7 Round Duct Plate from top...

Страница 5: ...NSTALLATION ONLY Connect ductwork to hood and use duct tape to make joints secure and air tight Make sure the damper duct connector enters the ductwork and that the damper opens and closes freely WARN...

Страница 6: ...E Suction Cup Tool included with hood can be used to install and remove light bulbs Align pins on bulb with large diameter opening on socket then push bulb up into socket and rotate clockwise until fi...

Страница 7: ...SSEMBLY includes Key Nos 6 7 and hardware 97018660 8 CONTROL ASSEMBLY WHITE 97019322 CONTROL ASSEMBLY BLACK 97019323 CONTROL ASSEMBLY STAINLESS STEEL 97019324 9 FAN BLADE INCLUDES HAIRPIN CLIP R531076...

Страница 8: ...ion or the other remaining provisions of the Limited Warranty Remedy During the applicable limited warranty period the Company will at its option provide replacement parts for or repair or replace wit...

Страница 9: ...la campana cuando est cocinando a altas temperaturas o flamee alimentos por ejemplo crepas Suzette cerezas Jubilee bistec con pimienta flameado 3 Limpie frecuentemente los ventiladores No permita la a...

Страница 10: ...ue quede en la campana alg n otro residuo de la construcci n Durante la construcci n o la renovaci n cubra la campana para estar seguro de que el polvo no se pegue a la superficie de acero inoxidable...

Страница 11: ...largos de conductos 4 Instale la tapa para pared o para techo Conecte un conducto met lico en la tapa y trabaje hacia atr s hacia la ubicaci n de la campana Use cinta para conductos para sellar las u...

Страница 12: ...TOR CONECTOR DEL REGULADOR DE TIRO CONDUCTO TORNILLOS 13 Retire la placa del conducto redondo de 7 pulg 17 8 cm de la parte superior trasera de la campana PLACA DEL CONDUCTO REDONDO DE 7 PULG 17 8 CM...

Страница 13: ...s en las uniones para fijarlas y sellarlas Aseg rese de que el conector del regulador de tiro conducto entre a los conductos y que el regulador de tiro pueda abrirse y cerrarse libremente ADVERTENCIA...

Страница 14: ...bombillas sean dif ciles de instalar b La bombilla sobresalga demasiado por debajo del panel de la bombilla PRECAUCI N Las bombillas podr an estar calientes Siempre permita que se enfr en las bombilla...

Страница 15: ...L DE CIRCUITO incluye tarjeta de control interface de usuario y piezas 97019365 9 ASPA DEL VENTILADOR INCLUYE SUJETADOR DE HORQUILLA R531076 10 SUJETADOR DE HORQUILLA R99420635 11 BOLSA DE PIEZAS DE M...

Страница 16: ...urso Durante el periodo de garant a limitada aplicable la Compa a a su opci n suministrar piezas de repuesto o reparar o reemplazar sin cargo alguno cualquier Producto o pieza del mismo hasta el grado...

Отзывы: