background image

 

 

Repeat48/Repeat48WDM

 

12 / 21 

rev. 2.1 

 

Rear Panel 

Repeat48 

 

 

 

Coax to fibre ports 1-24:

  Populated with up to 12 Dual channel electrical-optical-electrical  

3G/HD/SD-SDI or AES10/MADI modules.  
Each port can be configured by the manufacturer as:  
• Input  
• Output 

 

POWER 1 and 2:

 

AC input for power supply 1 and 2 (100 

 240 V) 

Optionally: DC input for power supply 1 and 2 with 4 pin XLR Male (8 

18V) 

 

 
Repeat48WDM 

 

 

Fibre ports 1-16: 

Up to 16 simplex LC fibre connections to internal WDM, CWDM or DWDM 
modules. 

 

 

Coaxial ports 1-24:

 

Populated with up to 12 Dual channel electrical-optical-electrical  
3G/HD/SD-SDI or AES10/MADI modules.  
Each port can be configured by the manufacturer as:  
• Input  
• Output 
The coaxial ports are connected internally to SFP fibre transceivers that feed 
the specified WDM, CWDM or DWDM multiplexers. 

 

POWER 1 and 2: 

AC input for power supply 1 and 2 (100 

 240 V). 

Optionally: DC input for power supply 1 and 2 with 4 pin XLR Male (8 

18V) 

 
 
 

 

 

 

 
   

Please note:

 

 

Refer to the DiViNe System Manual for system specifications and functionality.  

Refer  to  the  device’s  configuration  sheet  for  configuration  of  the 
Repeat48/Repeat48WDM 

Содержание Repeat48 Series

Страница 1: ... Repeat48 Repeat48WDM Operating Manual Rev 2 1 Operating Manual for Repeat48 Repeat48WDM Digital Video Network device Copyright 2017 All rights reserved BROAMAN GmbH Lohenstr 8 82166 Munich Gräfelfing Germany ...

Страница 2: ...Page intentionally left blank ...

Страница 3: ... Protect the power cord from being stepped on crushed pinched or damaged in any other way Pay special attention to plugs and sockets of the device Do not place this device on an unstable table tripod cart etc The device may fall causing serious damage to the device The device can be disconnected from the power supply by pulling the plug These must be freely accessible at all times The device shoul...

Страница 4: ...and audio visual and entertainment lighting control apparatus for professional use E1 Residental E2 Commercial and light industrial E3 Urban outdoors E4 Controlled EMC environment e g broadcast and TV studio E5 Heavy industry The product is intended for the use in moderate climate Ventilation Do not block or cover any ventilation openings Install the device in accordance to the operating manual Al...

Страница 5: ... the plugs and the sockets of the device Fuse There is no fuse in the device The power supplies contain circuitry that protects the device from overload Lightning For additional protection of this device during lightning storms or when it is left unattended and unused for a long period of time disconnect the power cord This will prevent damage to the device due to lightning and power line surges D...

Страница 6: ...al fibre cables are covered with the provided caps Do not place this device on an unstable table tripod cart etc The device may fall which can cause injury and serious damage to the device Any mounting of the device should follow the manufacturer s instructions and should use mounting accessories recommended by the manufacturer of the device Servicing Do not attempt to service the device by yourse...

Страница 7: ...ection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communication Operation of this equipment in a residential area is likely to cause harmful interference in which case you wi...

Страница 8: ...Page intentionally left blank ...

Страница 9: ...NC Ports 13 Fibre Ports 13 Multiplexers 13 Power Supply 13 Control 13 Connectors and Cables 14 3G HD SD SDI and MADI Ports 14 Optical Connections 14 Power Connection 14 Ordering Options 15 Repeat48 12 15 Repeat48 24 15 Repeat48WDM 12 16 Repeat48WDM 24 16 Connection Example 17 Technical Specifications 18 Dimensions and Weight 18 Warranty and Liability 19 Summary of Warranty 19 How to Obtain Warrant...

Страница 10: ...modular nature of DiViNe paves the way for construction of fully cost optimized systems Repeat48 Reepeat48WDM is an application engineered electrical optical electrical converter for 3G HD SD SDI or AES10 MADI signals converting between coaxial and optical connections Repeat48 Reepeat48WDM can be populated with up to 12 dual channel 3G HD SD SDI or AES10 MADI modules and SFP fibre optic transceive...

Страница 11: ...8 and Repeat48WDM Input status LED Signal indicator for channels 1 24 LED ON Signal is present LED OFF No signal is present PWR 1 LED Green Power supply 1 is operational and receiving power PWR 2 LED Green Power supply 2 is operational and receiving power ...

Страница 12: ...nternal WDM CWDM or DWDM modules Coaxial ports 1 24 Populated with up to 12 Dual channel electrical optical electrical 3G HD SD SDI or AES10 MADI modules Each port can be configured by the manufacturer as Input Output The coaxial ports are connected internally to SFP fibre transceivers that feed the specified WDM CWDM or DWDM multiplexers POWER 1 and 2 AC input for power supply 1 and 2 100 240 V O...

Страница 13: ...8WDM can optionally be populated with passive WDM CWDM or DWDM multiplexing module s as required by the application Power Supply The device is optionally equipped with two power supplies and inputs If the primary power supply were to fail due to disruption of the power source or in the case of a power supply malfunction the device will automatically switch over to the redundant power supply In ord...

Страница 14: ...9 µm fibre cable can be used for applications requiring cable lengths of up to 80 km dependent on bandwith and the quality of the optical cables AES10 MADI Multichannel Audio Multi mode AES10 MADI transceivers connected using a 62 5 µm OM1 fibre cable or better can be used for applications requiring cable lengths of up to 2000 m worst case Single mode AES10 MADI transceivers connected using a 9 µm...

Страница 15: ...OUT 12 x fiber IN 2 x PSU Repeat48 24 Code Description R4824002P Repeat48 24 24 x 3G SDI IN 24 x fiber OUT 2 x PSU R4822022P Repeat48 24 22 x 3G SDI IN 2 x 3G SDI OUT 2 x fiber IN 22 x fiber OUT 2 x PSU R4820042P Repeat48 24 20 x 3G SDI IN 4 x 3G SDI OUT 4 x fiber IN 20 x fiber OUT 2 x PSU R4818062P Repeat48 24 18 x 3G SDI IN 6 x 3G SDI OUT 6 x fiber IN 18 x fiber OUT 2 x PSU R4816082P Repeat48 24...

Страница 16: ...x COM 2 x PSU R48W20042PA4 Repeat48WDM 24 20 x 3G SDI IN 4 x 3G SDI OUT 2 x 1310nm AUX 2 x Optocore Tunnel 2 x COM 2 x PSU R48W18062PA4 Repeat48WDM 24 18 x 3G SDI IN 6 x 3G SDI OUT 2 x 1310nm AUX 2 x Optocore Tunnel 2 x COM 2 x PSU R48W16082PA4 Repeat48WDM 24 16 x 3G SDI IN 8 x 3G SDI OUT 2 x 1310nm AUX 2 x Optocore Tunnel 2 x COM 2 x PSU R48W14102PA4 Repeat48WDM 24 14 x 3G SDI IN 10 x 3G SDI OUT ...

Страница 17: ...modules 12 channels and 6 dual 3G SDI output modules The top device is configured with 6 dual 3G SDI input modules and the bottom device is configured with 6 dual 3G SDI output Each device is connected with six dual core single mode fibre cables to the central unit Fig 1 Connections between a Repeat48 12 12 to a Repeat48 12 0 and a Repeat48 0 12 Fig 2 Connections between a Repeat48WDM 8 8 to a Rep...

Страница 18: ...ing on the configuration of the device 32VA Max Security classification Class 1 basic insulation connected to the protective grounding conductor Security regulations Harmonised European standard EN60065 Mains connector acc to IEC 950 Cooling Passive via surface and ventilation openings on both sides of the device Dimensions and Weight Dimensions Front panel width 483 mm 19 inch height 44 mm 1 73 i...

Страница 19: ...When discovering a problem with an BROAMAN device you should contact either Broaman directly or a dealer distributor to determine and confirm a hardware fault If it is a software issue the hardware must not be returned to BROAMAN BROAMAN will issue a support ticket in this case If hardware service is required within the warranty period take the equipment along with warranty card to the nearest aut...

Страница 20: ...ational electric cables which have been supplied on your request and your purchase order cannot be listed above Please note that due to the Ecology reason standard shipment does not contain printed copy of User Manual All latest BROAMAN user manuals can be downloaded from the website http www broadcastmanufactur com index php support downloads Printed version of User Manual is available on a speci...

Страница 21: ...1 21 rev 2 1 Contact Information Mailing Address BROAMAN GmbH Lohenstr 8 D 82166 Munich Gräfelfing Germany Telephone 49 0 89 89996460 Facsimile 49 0 89 89996455 Internet www BroaMan com Email inquiry broadcastmanufactur com ...

Отзывы: