14 December 2010
Due to continued product improvement, Broady’s reserves the right to change product specifications without prior notification.
All Dimension are in mm………….Copyright ©
15
Locate the three self-tapping screws provided into the under-side of the top ledge of the firebox
Remove the backing tape from the adhesive Velcro pads at the bottom of each fascia side
Offer the fascia into position locating the three screws into their associated slots - tighten screws
Apply firm pressure to the bottom edges to bond the Velcro tape
The fascia may be removed at any time by loosening the screws and parting the Velcro
Please refer to additional sheet for Burner Ratings and Frame-out details.
FASCIA KIT (Black or Stainless Steel)
Your Fire must be Installed and Tested by a suitably qualified Gasfitter prior to use.
To light :
Lower the control-cover by pulling it outwards .
Depress the Ignition Switch and hold in the
'PILOT'
position for 3-5 seconds. (This may take some time for the Gas to come
through to the Pilot-3 Flame)
Strike the Igniter by turning to the
'STAR'
position , maintaining the Switch in a Depressed State ; (repeat steps 2 & 3 if neces-
sary)
Once the Pilot Flame is lit, hold this position for 3-5 seconds , release from the Depressed State
before setting the Flame Control to Full , it may take 3-5 seconds for the Burner to Light .
Once the Flame Bed is established, set the Flame Control to the desired level & close cover.
To shut down :
Open control cover by pulling it outwards.
Turn control switch to
'PILOT'
. Flame bed will extinguish.
Pilot light may be left running or extinguished by switching to
'OFF'
before closing cover.
OPERATION OF YOUR GAS CONVECTION FIRE (Manual ONLY)
Note:
Fascia is Fitted at the end of the
Installation process and may be
after the wall and surroundings
have been completed .