background image

Security Analytics Gen14 Dell Storage Quick Start Guide

SA

-

STAG8-2U144, SA

-

STXG8-2X144, SA

-

STAG8-5U840

3

4 —   Connect Cables

The following deployment documents a Sensor System with a 

single sensor (SA

-

SRVG8-20 or SA

-

SRVG8-40) connected to 

a storage array (SA

-

STAG8-2U144) with up to three expansion 

enclosures (SA

-

STXG8-2X144). For information on other 

deployments, see the Security Analytics documentation at: 

techdocs.broadcom.com

NOTE: 

Network cables are not included with the storage 

array. Make sure to use only straight-through Ethernet 

cables. Category 5E cables or better are recommended for 

1000Base-T operation. Category 6A cables are 

recommended for 10GBase-T operation.

NOTE: 

For SAS connections, use the 12Gb HD-Mini to HD-

Mini SAS cables included with the storage array, or equivalent.
1. Connect the storage array to the management network:

Connect an Ethernet cable to the storage array’s 

Network

 port on 

Controller A

. Connect the other end 

of the cable to the management network.

Connect an Ethernet cable to the storage array’s 

Network

 port on 

Controller B

. Connect the other end 

of the cable to the management network.

2. Connect the storage array to the sensor:

If the sensor has one RAID controller (see 

Figure 1

):

– Connect an SAS cable to the storage array’s 

SAS 0

 

port on 

Controller A

. Connect the other end of the 

cable to the sensor’s SAS 0 port (RAID 1).

– Connect an SAS cable to the storage array’s 

SAS 0

 

port on 

Controller B

. Connect the other end of the 

cable to the sensor’s SAS 1 port (RAID 1).

If the sensor has two RAID controllers, connect the 

following cables as well (see 

Figure 2

):

– Connect an SAS cable to the storage array’s 

SAS 1

 

port on 

Controller A

. Connect the other end of the 

cable to the sensor’s SAS 0 port (RAID 2).

– Connect an SAS cable to the storage array’s 

SAS 1

 

port on 

Controller B

. Connect the other end of the 

cable to the sensor’s SAS 1 port (RAID 2).

3. Daisy-chain up to three expansion enclosures from the 

storage array’s 

SAS_EXP

 ports (see 

Figure 3

).

4. Connect the included power cords to the storage array’s 

power inlets. Connect the other ends of the cords to 

separate power distribution systems.

SAS Cabling Examples

NOTE: 

For additional deployments and cable configurations, 

see the 

Security Analytics Gen14 Dell Configuration Guide

available at: 

techdocs.broadcom.com

Figure 1:  (1) SA

-

SRVG8-20 (1 RAID Controllers), 

(1) SA

-

STAG8-2U144

Figure 2:  (1) SA

-

SRVG8-20 (2 RAID Controllers), 

(1) SA

-

STAG8-2U144

Figure 3:  (1) SA

-

STAG8-2U144 (2 RAID Controllers), 

(1) SA

-

STAG8-2U144, (3) SA

-

STXG8-2X144s

Отзывы: