background image

Security Analytics Gen14 Dell Storage Quick Start Guide

SA

-

STAG8-2U144, SA

-

STXG8-2X144, SA

-

STAG8-5U840

2

using the washers and screws supplied.

Tighten the two clamping screws located along the 

inside of the rear section of the rack bracket.

Repeat preceding steps to install the right rail.

3. Install the 2U storage array into the rack:

Keeping the storage array level, carefully insert the 

chassis slides into the rack rails and push fully in.

Tighten the mounting screws in the rear kit brackets.

5U Storage Arrays

To rackmount the SA

-

STAG8-5U840:

1. Locate the components for installing the 5U rail kit:

2. To reduce weight, remove the storage array’s rear-panel 

controllers, per the instructions in the 

Dell EMC PowerVault 

ME4 Series Storage System Deployment Guide

.

3. Install the rack rails:

With the preassembled rails at their shortest length, 

locate the rail location pins inside the front of the rack, 

and extend the length of the rail assembly to position 

the rear location pins. Make sure the pins are fully 

inserted in the square or round holes in the rack posts.

Fully tighten all clamping screws and middle slide 

locking screws.

Make sure the four rear space clips (not shown) are 

fitted to the edge of the rack post.

4. Install the 5U storage array into the rack:

Slide the storage array into the rack until it is fully 

seated on its rails.

Secure the front and rear of the storage array using the 

fastening screws.

5. Reinstall the rear-panel controllers, per the instructions 

in the 

Dell EMC PowerVault ME4 Series Storage 

System Deployment Guide

.

CAUTION! 

Once the storage array is mounted, dispose of 

the lifting straps. The straps are not suitable for reuse.

3 —   Install Drives in the 

SA

-

STAG8-5U840

To install the 70 HDDs included with the SA

-

STAG8-5U840:

1. Open the top drive drawer:

Push the drawer latches inward and hold them.

Pull the drawer outward until it locks at the drawer stops.

2. Install half of the drives (35) in the drawer:

Install the drives from front to back in drive slots 0–34.

Align the drive with the target drive slot and insert it.

Push the drive downward and hold it.

Secure the drive by moving the slide latch to the left.

3. Close the bottom drawer:

Press and hold the drawer latches on the sides of the 

open drawer.

Push the drawer in slightly and release the latches.

Push the drawer all way the into the enclosure, making 

sure that it clicks in place.

4. Repeat the preceding steps to install the remaining 

drives (35) in the bottom drive drawer.

Item

Description

1

Fastening screws (A)

2

Left rail

3

Rear rack post square hole

4

Clamping screw (B)

5

Middle slide locking screws

6

Rear left portion of 5U chassis

7

Front rack post square hole

8

Front left portion of 5U chassis shown for reference

9

Middle slide locking screws

A

B

C

8

3

4

1

7

2

5

6

1

4

9

Отзывы: