![Broadcom G610 Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/broadcom/g610/g610_hardware-installation-manual_2815739009.webp)
53-1004408-11 Installation Guide
Brocade
®
G610 Switch Hardware Installation Guide
–
If one fan fails and the temperature is less than 56°C (132.8°F), the fans run at high speed. If the temperatures
increase by more than 56°C (132.8°F), a critical temperature warning is displayed and the device shuts down in 2
minutes.
–
If two fans fail and the temperature is less than 55°C (131°F), the fans run at high speed. If the temperature
increases more than 55°C (131°F), a critical temperature warning is displayed and the device shuts down in 2
minutes.
–
If the third fans fail, a warning is displayed and the device is immediately shut down.
•
Hardware-enabled input and output (I/O) latency statistics collection.
•
Hardware-enabled VM support.
•
1U chassis that can be installed as a stand-alone unit or mounted in a standard Electronic Industries Association (EIA)
48.26cm (19 in.) cabinet or rack.
•
Support for Brocade small form-factor pluggable plus (SFP+) optical transceivers in any combination of short
wavelength (SWL), long wavelength (LWL), or extended long wavelength (ELWL) optical media.
•
Extended distance Fibre Channel to support long-distance native FC connectivity.
•
Port-to-port latency is minimized to 900 ns including FEC using cut-through frame switching at 32G.
•
A dual-core T1022E processor operating at 1.2 GHz delivers high-performance, scalability, and advanced Fabric
Vision functionality.
•
One 1000/100/10Mb/s RJ-45 Ethernet connector for the management connection. With EZSwitchSetup, this port
supports switch IP address discovery and configuration, eliminating the need to attach a serial cable to configure the
switch IP address.
•
An RS-232 3-wire (Tx, Rx, and Gnd) universal asynchronous receiver/transmitter (UART) serial port to BMC adapter
with an RJ-45 connector for debugging initial switch setup (if not using EZSwitchSetup) and factory default restoration
is included with the switch. Although there are LEDs in the adapter, they are not used.
•
An internal e-USB module with 2 GB of persistent storage. The e-USB module provides increased serviceability, and
error logging functionality by facilitating easier firmware upgrades and downloads of the system log files.
•
One external USB connector.
•
24 hot-pluggable SFP+ optical transceiver slots.
•
24 bicolor (green/amber) LEDs to indicate the status for each port.
•
One green LED to indicate valid system power.
•
One bicolor (green/amber) LED to indicate the system status.
•
Two Ethernet LEDs: one bicolor (green/amber) LED to indicate the link speed (1000/100/10Mb/s) and one green LED
to indicate traffic activity.
•
A Serial EEPROM for switch identification.
•
Real-time fan monitoring.
•
Real-time digital thermometers for temperature monitoring.
•
Real-time clock (RTC) with battery.
License Options
The Brocade G610 uses a capacity-based Dynamic-POD license method and can be purchased with 8, 16, or 24 licensed
ports. The first eight ports (0-7) are enabled by default. To enable the remaining sixteen ports, you need to purchase and
install two 8-port POD license keys. Refer to the
Brocade Fabric OS Software Licensing Guide
for more details.