53-1004106-15 Installation Guide
Brocade
®
X6-4 Director Hardware Installation Guide
CAUTION
Before plugging a cable into any port, be sure to discharge the voltage stored on the cable by touching the
electrical contacts to ground surface.
CAUTION
To avoid damaging blade and chassis, do not push the blade into a slot or pull the blade from a slot using the
ejector handles.
Blade Fault Indicators
Confirm that you need to replace the CP blade. The following events may indicate that a CP blade is faulty:
•
The status LED on the CP blade is lit steady amber, or the power LED is not illuminated. See
for details on interpreting LED operation.
•
The CP blade does not respond to telnet commands, or the serial console is not available.
•
The
haShow
command indicates an error.
•
The clock is inaccurate, or the CP blade does not boot up or shut down normally.
•
Any of the following messages display in the error log:
–
"Slot unknown" message relating to a CP slot
–
CP blade errors or I2C timeouts
–
FRU: FRU_FAULTY messages for a CP blade
–
Configuration loader messages or "Sys PCI config" messages
–
Generic system driver messages ("FABSYS")
–
Platform system driver messages ("Platform")
–
EM messages that indicate a problem with a CP blade
–
Function fail messages for the CP master
See
and refer to the
Brocade Fabric OS Command Reference Manual
for output examples
and additional information on Fabric OS commands.
For more information about error messages, refer to the
Brocade Fabric OS Message Reference Manual
.
Blade Replacement Task Guide
This section contains a guide to more complete, detailed steps in this section for installing or replacing CP blades when
the device is running (hot-swap) or must be powered off (cold swap). References are provided to the more detailed blade
removal and installation steps for further information.
Replacing a CP Blade (Hot-Swap)
For hot-swap replacement, the chassis continues to operate while a CP blade is being replaced if the redundant CP blade
is active and failover does not occur. You can prevent failover by entering the
haDisable
command. You can replace one
blade or both blades one at a time using these steps. Follow all steps for one blade, and then repeat the same steps to
replace the other blade.
1. Prepare for replacing the blade by following all steps under
2. Remove the blade from the slot by following all steps under
3. Install a new blade into the empty slot by following all steps under
4. Verify and synchronize firmware on both blades by following all steps under
Verifying and Synchronizing Firmware on
.
If you need to download firmware to update the blades, follow the steps in one of the following sections:
•
Downloading Firmware from an FTP Server
•
Downloading Firmware from a USB Device
53-1004106-15
125
Содержание Brocade X6-4
Страница 208: ......