WVRC-4 Plus Installation and Operation Manual
SET UP
“Email/Network Setup” Web Page – NTP Settings
NTP (Time) Server Address: Enter the NTP address here. Default: pool.ntp.org
NTP Port:
Normally 123.
Default: 123
NTP Update Interval (Min): Interval between timing updates.
Default: 30
NTP Enabled:
Must be enabled to sync .
Default: Enabled
“Email/Network Setup” Web Page – Other Settings
Site ID:
This is the Site Identifier that is display on the web
ieach email.
Monitor Refresh Time (Sec): Interval at which the Monitor page refreshes. Shorter
times may increase network traffic.
MTU Size:
The Maximum Transmission Unit (MTU) is the
largest physical packet size a network can transmit for
TCP and UDP. Enter between 512 and 1400 bytes.
The default is 1400 bytes.
Time Zone Offset from UTC:Sets the timezone.
Default: -8
Set Time:
The hour, minute, second, month, day and year boxes
can be used to set the time of the RTC. The time is
only updated if you click “Save Time” and not when
you “Save Settings”.
Enable Event Logging:
Enabling these checkboxes will generate an alarm, but
will not send an email. If the system is configured for
Daily Alarm emails, then that Daily Alarm email will
contain the Event Logging items as well.
Login:
Whenever someone logs into the system, the user-
name and date/time will be logged.
Email:
Whenever an email is sent, the type of email and
date/time will be logged.
Reboot:
Whenever the device boots, the date/time will be
logged.
Alarms Cleared:
Whenever the Daily Logs or Normal Alarms are
cleared, the type of log cleared and date/time will be
stored. When Daily Logs are sent, the Daily Logs are
also cleared; this will cause an event log as well.