VAD-2 Plus Installation and Operation Manual

PROGRAMMING

Disabled

73

2.5

Relay 1

74

5

Relay 2

75

5

Remote Program enabled

76

10

Access Accepted

77

5

Minus

78

2.5

The “Call out ID” message is used to identify the source of an alarm call-out, for
example, WXYZ will be played prior to “Input 1 Alarm” being spoken.

Restoring to factory defaults:  

Remove the power plug.  Hold in the recessed front panel “PGM” button.

Plug in the power connector and then release the “PGM” button a second or two
later.  You will hear 4 beeps in the programming telephone indicating the defaults
have been restored.  

NOTE:  Factory recorded voice responses are not restored. 

DIP switch setup

DIP 1 – OFF = Normal operation
DIP 1 - ON = BOTT mode.  The BOTT function can be activated either by using
input 1 or with the silent sensor, but not both at the same time.  If the Silent Sensor
is enabled, then input 1 will be ignored.  If the Silent Sensor is disabled then when
input 1 closes, the VAD-2 Plus will dial out the number assigned to the Dial List 1
location.  If the input remains closed for 15 seconds, relay 1 will close and caller
audio output will be turned on.  If input 1 opens for 1 minute, then the VAD-2 Plus
will hang up, open relay 1 and turns off the caller audio output.  If the telco line is
lost due to a CPC event, then the VAD-2 Plus will hang up and repeat the dial out
process if input 1 is still closed.

If the Silent Sensor is enabled and DIP-1 is ON and program audio is lost for the
programmed time period, then the VAD-2 Plus will dial out the number located in
Dial List 1, turn on both relay 1 and caller output.  If program audio is restored, then
the VAD-2 Plus will hang up, turn OFF Relay 1 and the caller audio output

DIP 2 – OFF = Degrees Fahrenheit / ON = Degrees Celsius for polling only.
Temperature set points are determined by program entries 28 and/or 29.

DIP 3 – OFF = Normal relay operation for K1 & K2 / ON = K2 closes on all alarms

DIP 4 thru 7 = Feature creep 

DIP 8 – OFF = Alarms enabled / ON = Alarms disabled

WEBSITE:

Visit our web site for
product updates and
additional information

Содержание tiny TOOLS VAD - 2 Plus

Страница 1: ...d trademark of Broadcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tool...

Страница 2: ...ing you equipment 10 Status inputs 10 Silence sensor inputs 10 Power failure input 11 Temperature probe 11 External power supply output 11 Relays 11 Telco Caller audio output 11 Power supply input 11...

Страница 3: ...re problems If you experience these problems please research your hardware software instruction man uals or contact the manufacturers technical support department WHO TO CONTACT FOR HELP If you have a...

Страница 4: ...arm is activated Features Two user programmable wet or dry optically isolated status inputs Optional Fahrenheit Celsius temperature sensor probe Stereo Silence Sensor with remote telco audio monitorin...

Страница 5: ...ack labeled Phone Pgm and plug in a standard TT telephone 2 Press the recessed front panel PGM button the front panel PGM led will illuminate 3 Enter the command code of the desired operation followed...

Страница 6: ...ode You must call the VAD 2 Plus and enter the remote access code Dial List is a list of the Dial out phone numbers that will be dialed for a particular alarm The numbers correspond to the dial out ad...

Страница 7: ...ensor Delay Timer 31 1 3 The delay time is programmed with a value of 1 to 9 with values as follows 1 10 secs 2 30 secs 3 60 secs 4 90 secs 5 2 mins 6 2 5 mins 7 3 mins 8 4 mins and 9 5 mins Power Fai...

Страница 8: ...the new message using the programming phone When done press the PGM button again or wait for the time out When recording remotely you must first dial in and enter the remote access code The VAD 2 Plu...

Страница 9: ...Silent Sensor is disabled then when input 1 closes the VAD 2 Plus will dial out the number assigned to the Dial List 1 location If the input remains closed for 15 seconds relay 1 will close and caller...

Страница 10: ...er The IN 1 jumpers support status input one while IN 2 supports status input two Each input is labeled IN x where x is the status input and the header pins are labeled from left to right 1 2 3 4 as v...

Страница 11: ...for relay one is between the K1NO K1NC and K1CM terminals Relay two is between terminals K2NO K2NC and K2CM Limit contact current to 1 amp at 30 vdc Note For safety never connect 120 Vac circuits to...

Страница 12: ...the VAD 2 Plus is ready to receive commands after the secu rity un lock code is entered through your telephone keypad Functions include telling the VAD 2 Plus to report on the input state of any of t...

Страница 13: ...elay 1 1 second pulse 1 Relay 1 latched 1 Relay 1 un latched 21 Enable Input 2 alarm 22 Disable Input 2 alarm 23 Poll Input 2 Enable Status 27 Poll Input 2 State Status 28 Poll Relay 2 29 Steady Relay...

Страница 14: ...d in an alarm condition Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid DTMF tone Pwr led OFF in voice record mode Hook led ON when in an of...

Страница 15: ...0K ohm inputs Trip level 20dBu Silence sensor level to Telco adjustable Balanced caller audio output 0 dbu 100 ohms Gain may be changed to increase output Telephone Line Connector RJ 11 Cable supplied...

Страница 16: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Страница 17: ...OFF with NO audio SS led flashes if enabled and in an alarm condition Optional Temp Probe Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid D...

Страница 18: ...5678 then press the front panel recessed program push button to exit programming mode 7 Press the front panel recessed program push button to enter programming mode 8 Enter the memory location you nee...

Страница 19: ...essed program push button to exit programming mode 23 Press the front panel recessed program push button to enter programming mode 24 Enter the memory location you need to program Example Number of LA...

Страница 20: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 20 APPENDIX...

Страница 21: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 21 APPENDIX...

Отзывы: