VAD-2 Plus Installation and Operation Manual
PROGRAMMING
Disabled
73
2.5
Relay 1
74
5
Relay 2
75
5
Remote Program enabled
76
10
Access Accepted
77
5
Minus
78
2.5
The “Call out ID” message is used to identify the source of an alarm call-out, for
example, WXYZ will be played prior to “Input 1 Alarm” being spoken.
Restoring to factory defaults:
Remove the power plug. Hold in the recessed front panel “PGM” button.
Plug in the power connector and then release the “PGM” button a second or two
later. You will hear 4 beeps in the programming telephone indicating the defaults
have been restored.
NOTE: Factory recorded voice responses are not restored.
DIP switch setup
DIP 1 – OFF = Normal operation
DIP 1 - ON = BOTT mode. The BOTT function can be activated either by using
input 1 or with the silent sensor, but not both at the same time. If the Silent Sensor
is enabled, then input 1 will be ignored. If the Silent Sensor is disabled then when
input 1 closes, the VAD-2 Plus will dial out the number assigned to the Dial List 1
location. If the input remains closed for 15 seconds, relay 1 will close and caller
audio output will be turned on. If input 1 opens for 1 minute, then the VAD-2 Plus
will hang up, open relay 1 and turns off the caller audio output. If the telco line is
lost due to a CPC event, then the VAD-2 Plus will hang up and repeat the dial out
process if input 1 is still closed.
If the Silent Sensor is enabled and DIP-1 is ON and program audio is lost for the
programmed time period, then the VAD-2 Plus will dial out the number located in
Dial List 1, turn on both relay 1 and caller output. If program audio is restored, then
the VAD-2 Plus will hang up, turn OFF Relay 1 and the caller audio output
DIP 2 – OFF = Degrees Fahrenheit / ON = Degrees Celsius for polling only.
Temperature set points are determined by program entries 28 and/or 29.
DIP 3 – OFF = Normal relay operation for K1 & K2 / ON = K2 closes on all alarms
DIP 4 thru 7 = Feature creep
DIP 8 – OFF = Alarms enabled / ON = Alarms disabled