Broadcast Tools tiny TOOLS VAD - 2 Plus Скачать руководство пользователя страница 19

e-mail: 

[email protected]   

voice: 

360.854.9559   

fax: 

866.783.1742 

19

VAD-2 Plus Installation and Operation Manual

APPENDIX

16 - Enter the memory location you need to program.   

Example:  Ring count = 303 then press the front panel (recessed) program
push button to exit programming mode.

17 - Press the front panel (recessed) program push button to enter programming mode.
18 - Enter the memory location you need to program.  

Example:  10 second Silence Sensor delay = 311 then press the front panel
(recessed) program push button to exit programming mode.

19 - Press the front panel (recessed) program push button to enter programming mode.
20 - Enter the memory location you need to program.  

Example:  Hang-up timer = 331 then press the front panel (recessed) program
push button to exit programming mode. 

NOTE:  (I would keep this at 1 (minute), as the CO may not always send the CPC
signal or if your PBX doesn’t supply CPC (Telco auto hang-up signal, referred to
CPC, WINK or COD).

21 - Press the front panel (recessed) program push button to enter programming mode.
22 - Enter the memory location you need to program.  

Example:  Silence Sensor ENABLE = 361 then press the front panel
(recessed) program push button to exit programming mode.

23 - Press the front panel (recessed) program push button to enter programming mode.
24 - Enter the memory location you need to program.  

Example:  Number of LAPS = 423 then press the front panel (recessed) pro-
gram push button to exit programming mode.

25 - Press the front panel (recessed) program push button to enter programming mode.
26 - Enter the memory location you need to program.  

Example:  Record Silence Sensor message (10 seconds) = 65 then press the
front panel (recessed) program push button to exit programming mode.

27 - Press the front panel (recessed) program push button to enter programming mode.
28 - Enter the memory location you need to program.  

Example:  Record greeting message = 68 then press the front panel (recessed)
program push button to exit programming mode.

The silence sensor inputs are unbalanced.  Connect your unbalanced source equip-
ment to either or both inputs (SSL) and/or (SSR).  The shield tied to the GND ter-
minal.  If your source equipment is balanced, use the “+” and GND terminal from
the source.  Your source equipments “-” (negative) terminal should never be
grounded.  Shields should be tied to the “Chs Gnd” terminal.  

The SS LED is illuminated when you have audio applied to the inputs.  When the
SS is in an alarm condition, the SS LED will flash.  NOTE: The SS led will be
extinguished with no audio input. 

Содержание tiny TOOLS VAD - 2 Plus

Страница 1: ...d trademark of Broadcast Tools Inc tiny TOOLS is a trademark of Broadcast Tools Inc All Sentinel labeled products are registered trademarks of Broadcast Tools Inc Copyright 1989 2011 by Broadcast Tool...

Страница 2: ...ing you equipment 10 Status inputs 10 Silence sensor inputs 10 Power failure input 11 Temperature probe 11 External power supply output 11 Relays 11 Telco Caller audio output 11 Power supply input 11...

Страница 3: ...re problems If you experience these problems please research your hardware software instruction man uals or contact the manufacturers technical support department WHO TO CONTACT FOR HELP If you have a...

Страница 4: ...arm is activated Features Two user programmable wet or dry optically isolated status inputs Optional Fahrenheit Celsius temperature sensor probe Stereo Silence Sensor with remote telco audio monitorin...

Страница 5: ...ack labeled Phone Pgm and plug in a standard TT telephone 2 Press the recessed front panel PGM button the front panel PGM led will illuminate 3 Enter the command code of the desired operation followed...

Страница 6: ...ode You must call the VAD 2 Plus and enter the remote access code Dial List is a list of the Dial out phone numbers that will be dialed for a particular alarm The numbers correspond to the dial out ad...

Страница 7: ...ensor Delay Timer 31 1 3 The delay time is programmed with a value of 1 to 9 with values as follows 1 10 secs 2 30 secs 3 60 secs 4 90 secs 5 2 mins 6 2 5 mins 7 3 mins 8 4 mins and 9 5 mins Power Fai...

Страница 8: ...the new message using the programming phone When done press the PGM button again or wait for the time out When recording remotely you must first dial in and enter the remote access code The VAD 2 Plu...

Страница 9: ...Silent Sensor is disabled then when input 1 closes the VAD 2 Plus will dial out the number assigned to the Dial List 1 location If the input remains closed for 15 seconds relay 1 will close and caller...

Страница 10: ...er The IN 1 jumpers support status input one while IN 2 supports status input two Each input is labeled IN x where x is the status input and the header pins are labeled from left to right 1 2 3 4 as v...

Страница 11: ...for relay one is between the K1NO K1NC and K1CM terminals Relay two is between terminals K2NO K2NC and K2CM Limit contact current to 1 amp at 30 vdc Note For safety never connect 120 Vac circuits to...

Страница 12: ...the VAD 2 Plus is ready to receive commands after the secu rity un lock code is entered through your telephone keypad Functions include telling the VAD 2 Plus to report on the input state of any of t...

Страница 13: ...elay 1 1 second pulse 1 Relay 1 latched 1 Relay 1 un latched 21 Enable Input 2 alarm 22 Disable Input 2 alarm 23 Poll Input 2 Enable Status 27 Poll Input 2 State Status 28 Poll Relay 2 29 Steady Relay...

Страница 14: ...d in an alarm condition Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid DTMF tone Pwr led OFF in voice record mode Hook led ON when in an of...

Страница 15: ...0K ohm inputs Trip level 20dBu Silence sensor level to Telco adjustable Balanced caller audio output 0 dbu 100 ohms Gain may be changed to increase output Telephone Line Connector RJ 11 Cable supplied...

Страница 16: ...OTHER WARRANTIES OR REMEDIES TO THE MAXIMUM EXTENT PERMITTED BYAPPLICABLE LAW BROADCAST TOOLSAND ITS SUPPLIERS DISCLAIMALL OTHER WARRANTIES EITHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPL...

Страница 17: ...OFF with NO audio SS led flashes if enabled and in an alarm condition Optional Temp Probe Pwr led ON if powered Pwr led flashes if PF is enabled and in an alarm condition Pwr led OFF during a valid D...

Страница 18: ...5678 then press the front panel recessed program push button to exit programming mode 7 Press the front panel recessed program push button to enter programming mode 8 Enter the memory location you nee...

Страница 19: ...essed program push button to exit programming mode 23 Press the front panel recessed program push button to enter programming mode 24 Enter the memory location you need to program Example Number of LA...

Страница 20: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 20 APPENDIX...

Страница 21: ...e mail support broadcasttools com voice 360 854 9559 fax 866 783 1742 VAD 2 Plus Installation and Operation Manual 21 APPENDIX...

Отзывы: