7.1
7.2
ON SITE
MAINTENANCE
TEST CONDITIONS
CPE/MS 526 Issue 2 (12/88)
Part 7
MAINTENANCE
In order to restore customer service
as
quickly as possible, a policy of
changing out faulty apparatus should
be
adopted. On site repair of faulty
items should
be
limited to the replacement of parts shown in the Parts List
(page9.1).
To provide all the spares required for faulting the CCV, a Maintenance Kit
should
be
made up locally. It should consist of the following items.
One Power Unit
One Exchange Line ASU
One Extension Interface ASU
One Modified Extension Interface ASU for use with the IPBX Adaptor
One Intercom ASU (LD or MF as appropriate)
One Microprocessor Backplane
One SENATOR terminal
Spare power fuses
One Adaptor SA 10253
One Adaptor SA 10254
One Adaptor SA 10255
The item codes and descriptions of these items are given in Section 9. A
suitable carrying case for the Maintenance Kit is available (Case 265A). N.B.
Case 265A will not hold a Power Unit.
On site maintenance of SENATOR systems is by functional testing, logic
diagnosis, ASU changeout or system replacement.
NOTE
The mains power supply to the Senator
System must be switched off before the
Power Unit or an ASU is removed or
replaced.
The exchange lines test normal DEL conditions but will test 'low loop' if a
megger test is used.
When testing within the system from a SENATOR telephone towards the
CCV both the speech pair and data pair test approx. 45v d.c. The speech and
data pair must not
be
allowed to come into contact, nor should the data pair
be reversed.
Each time a system is powered up, the CCUdetermines which extensions are
spare by testing if a telephone is connected or not. Only those extensions
which have a telephone connected are regarded
as
working extensions, and
are 'switched on'. Number Unobtainable tone is returned to an extension
which calls a spare extension.
When a telephone is plugged in to a previously spare extension, that
extension will
be
automatically 'switched on' by the CCV, and will work
normally. If the telephone is subsequently removed, the extension will
remain 'switched on' until the system undergoes another powering up
sequence.
7.3
Содержание Senator
Страница 1: ......
Страница 2: ......
Страница 3: ...British 1 EL ECO System manual ...
Страница 6: ...SENATOR SWITCHING SYSTEM iv CPE MS 526 Issue 2 12 88 ...
Страница 8: ...Part 1 GENERAL DESCRIPTION 1 2 CPE MS 526 Issue 2 12 88 ...
Страница 10: ...Part 2 INSTALLATION 2 2 CPE MS 526 Issue 2 12 88 ...
Страница 22: ...Part 3 THE TERMINAL 3 2 CPE MS 526 Issue 2 12 88 ...
Страница 26: ...Part 4 COMMISSIONING PROCEDURES 4 2 CPE MS 526 Issue 2 12 88 ...
Страница 28: ...5 2 Part 5 FACILITIES AND OPERATING PROCEDURES CPE MS 526 Issue 2 12 88 ...
Страница 37: ...Part 7 MAINTENANCE 7 2 CPE MS 526 Issue 2 12 88 ...
Страница 43: ...Part 7 MAINTENANCE 7 8 CPE MS 526 Issue 2 12 88 ...
Страница 45: ...Part 8 HOW IT WORKS 8 2 CPE MS 526 Issue 2 12 88 ...
Страница 47: ...9 2 Part 9 PARTS LIST OF CURRENT EQUIPMENT FOR SENATOR CPE MS 526 Issue 2 12 88 ...
Страница 49: ...Part 10 AUXILIARY EQUIPMENT 10 2 CPE MS 526 Issue 2 12 88 ...
Страница 69: ...Part 11 DOCUMENTATION 11 2 CPE MS 526 Issue 2 12 88 ...
Страница 71: ...Part 12 SPECIFICATION 12 2 CPE MS 526 Issue 2 12 88 ...
Страница 72: ...Part 12 SPECIFICATION 12 3 CPE MS 526 Issue 2 12 88 ...
Страница 73: ...Part 12 SPECIFICATION 12 4 CPE MS 526 Issue 2 12 88 ...
Страница 74: ......
Страница 75: ......