![British Telecom ESCORT Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/british-telecom/escort/escort_system-manual_2814488008.webp)
2.
CAPACITIES, SIZES AND WEIGHTS
The m aximum capacities of the system are as follow s:-
Exchange lines
2
Extensions
6
Intercom circuits
1
The
CCU
has the following dimensions and weight:
height
width
depth
weight
225mm
320mm
85mm
4 Kg (approx)
The key module has the following dimensions and weight:
height
width
depth
weight
3.
INSTALLATION
40mm
180mm
155mm
0.4 Kg
3.1
LOCATION OF THE CCU
The
CCU
has no s pecial site req uirem ent s other than that it
should be located in a normal off ice environment, with adequate
access for installation and maintenance.
The
CCU
shoul d be mounted horizontally, ad jacent to a suitable
socket outlet, such that the markings on the front cover have the
correc t orient ation.
There must be at leas t lOO m m clear space
all around the
CCU
to f acilitate servicing and ventilation. The
CCU
should not be mounted above radiators or in direct sunlight.
Where conditions permit the
CCU
should be mounted approximately
1350 m m from floor level to facilitate cable connection.
3.2
INSTALLING THE CCU
This section should be read in conjunction with f ig.3.1. w hich
sho w s the g eneral l ayout of the
CCU.
Do not connect the m ains
s u p p ly to the
C C U
u ntil all w i ring and c a bli n g h a s been
completed .